Studies on hydrogen–oxygen systems in the electrical discharge. III. Surface effects

1970 ◽  
Vol 48 (13) ◽  
pp. 2042-2046 ◽  
Author(s):  
Paul E. Brunet ◽  
Xavier Deglise ◽  
Paul A. Giguère

Surface effects in the reactions of dissociated hydrogen–oxygen systems and the products condensed therefrom have been investigated. Water vapor at about 0.1 Torr was streamed at high velocity through an electrodeless discharge confined in tubes of different materials or with various surface coatings. In all cases the products trapped in liquid nitrogen evolved oxygen gas on warming, but the relative amounts varied considerably from one type of surface to another. In some cases there was clear evidence that the walls of discharge tube were attacked by hydrogen atom bombardment. The decomposition, both thermal and electrical, of pure hydrogen peroxide vapor was studied likewise. The pyrolysis products gave off very little oxygen on warming. By contrast the products from electrical decomposition, even at low power level, evolved much oxygen, most of it above the melting point.It is concluded that there is always some decomposition of hydrogen peroxide in the trapped products. However, this does not seem sufficient to account for all the evolved oxygen; at least not in the case of dissociated water vapor.

1966 ◽  
Vol 44 (8) ◽  
pp. 869-876 ◽  
Author(s):  
Norisuke H Ata ◽  
Paul A. Glguère

Hydrogen gas partly dissociated in an electrodeless discharge was mixed downstream with hydrogen peroxide vapor at low pressure (0.1 mm Hg) in a liquid nitrogen trap. The reaction products condensed readily on the wall as a clear, yellowish glass resembling that from dissociated water vapor and other related systems. A manometric study of the warming-up process has revealed four distinct steps. The first two, in which only traces of gas are given off, look like the recombination of trapped free radicals. The major evolution of oxygen upon crystallization of the glassy deposit at 160 °K is ascribed to the decomposition of hydrogen peroxide under the influence of some unidentified species generated in the electric discharge through hydrogen. Experimental evidence for this is presented. In any case the stoichiometry cannot be reconciled with the formation of a metastable intermediate, such as the hypothetical polyoxide H2O4.In the last step beginning around 215 °K more peroxide is decomposed during the eutectic melting of the solid. Qualitatively these phenomena are similar to those shown by the condensate from dissociated water vapor.


1953 ◽  
Vol 31 (3) ◽  
pp. 262-271 ◽  
Author(s):  
J. S. Batzold ◽  
C. Luner ◽  
C. A. Winkler

The products of the electrical discharge through hydrogen peroxide vapor were hydrogen peroxide, water, oxygen, and hydrogen, in amounts which depended upon the arrangement and temperature of the trap, reaction time, and surface to volume ratio of the reaction vessel. Water, hydrogen, and oxygen resulted from the gas phase reactions of the dissociated hydrogen peroxide, with hydrogen peroxide produced only in a trap cooled below −120 °C. Products trapped below −150 °C evolved oxygen on warming to room temperature. The decomposition products of the electrical discharge through hydrogen peroxide correspond closely with products obtainable both from a similar discharge through water vapor and from the interaction of hydrogen atoms with oxygen molecules in a cold trap. A mechanism which accounts for their correspondence is included. Water was the only product when molecular hydrogen peroxide was caused to react with hydrogen atoms, dissociated hydrogen peroxide vapor, or dissociated water vapor in the presence or absence of molecular hydrogen. A chain mechanism is postulated for these reactions.


Author(s):  
B. Dodet ◽  
E. Odic ◽  
A. Goldman ◽  
M. Goldman ◽  
D. Renard

AbstractHydrogen peroxide production was studied in an atmospheric pressure dielectric barrier discharge device. The discharge atmosphere was an argon/oxygen gas mixture of variable ratio with water vapor adjunction; H


From the fact that no carbonic acid gas is given out by venous blood when that fluid is subjected to the action of the air-pump, former experimentalists had inferred that this blood contains no carbonic acid. The author of the present paper contends that this is an erroneous inference; first, by showing that serum, which had been made to absorb a considerable quantity of this gas, does not yield it upon the removal of the atmospheric pressure; and next, by adducing several experiments in proof of the strong attraction exerted on carbonic acid both by hydrogen and by oxygen gases, which were found to absorb it readily through the medium of moistened membrane. By means of a peculiar apparatus, consisting of a double-necked bottle, to which a set of bent tubes were adapted, he ascertained that venous blood, agitated with pure hydrogen gas, and allowed to remain for an hour in contact with it, imparts to that gas a considerable quantity of carbonic acid. The same result had, indeed, been obtained, in a former experiment, by the simple application of heat to venous blood confined under hydrogen gas; but on account of the possible chemical agency of heat, the inference drawn from that experiment is less conclusive than from experiments in which the air-pump alone is employed. The author found that, in like manner, atmospheric air, by remaining, for a sufficient time, in contact with venous blood, on the application of the air-pump, acquires carbonic acid. The hypothesis that the carbon of the blood attracts the oxygen of the air into the fluid, and there combines with it, and that the carbonic acid thus formed is afterwards exhaled, appears to be inconsistent with the fact that all acids, and carbonic acid more especially, impart to the blood a black colour; whereas the immediate effect of exposing venous blood to atmospheric air, or to oxygen gas, is a change of colour from a dark to a bright scarlet, implying its conversion from the venous to the arterial character: hence the author infers that the acid is not formed during the experiment in question, but already exists in the venous blood, and is extracted from it by the atmospheric air. Similar experiments made with oxygen gas, in place of atmospheric air, were attended with the like results, but in a more striking degree and tend therefore to corroborate the views entertained by the author of the theory of respiration. According to these views, it is neither in the lungs, nor generally in the course of the circulation, but only during its passage through the capillary system of vessels, that the blood undergoes the change from arterial to venous; a change consisting in the formation of carbonic acid, by the addition of particles of carbon derived from the solid textures of the body, and which had combined with the oxygen supplied by the arterial blood: and it is by this combination that heat is evolved, as well as a dark colour imparted to the blood. The author ascribes, however, the bright red colour of arterial blood, not to the action of oxygen, which is of itself completely inert as a colouring agent, but to that of the saline ingredients naturally contained in healthy blood. On arriving at the lungs, the first change induced on the blood is effected by the oxygen of the atmospheric air, and consists in the removal of the carbonic acid, which had been the source of the dark colour of the venous blood; and the second consists in the attraction by the blood of a portion of oxygen, which it absorbs from the air, and which takes the place of the carbonic acid. The peculiar texture of the lungs, and the elevation of temperature in warm-blooded animals, concur in promoting the rapid production of these changes.


2011 ◽  
Vol 32 (9) ◽  
pp. 831-836 ◽  
Author(s):  
T. Holmdahl ◽  
P. Lanbeck ◽  
M. Wullt ◽  
M. H. Walder

Objective.New technologies have emerged in recent years for the disinfection of hospital rooms and equipment that may not be disinfected adequately using conventional methods. There are several hydrogen peroxide–based area decontamination technologies on the market, but no head-to-head studies have been performed.Design.We conducted a head-to-head in vitro comparison of a hydrogen peroxide vapor (HPV) system (Bioquell) and an aerosolized hydrogen peroxide (aHP) system (Sterinis).Setting.The tests were conducted in a purpose-built 136-m3test room.Methods.One HPV generator and 2 aHP machines were used, following recommendations of the manufacturers. Three repeated tests were performed for each system. The microbiological efficacy of the 2 systems was tested using 6-log Tyvek-pouchedGeobacillus stearo-thermophilusbiological indicators (BIs). The indicators were placed at 20 locations in the first test and 14 locations in the subsequent 2 tests for each system.Results.All BIs were inactivated for the 3 HPV tests, compared with only 10% in the first aHP test and 79% in the other 2 aHP tests. The peak hydrogen peroxide concentration was 338 ppm for HPV and 160 ppm for aHP. The total cycle time (including aeration) was 3 and 3.5 hours for the 3 HPV tests and the 3 aHP tests, respectively. Monitoring around the perimeter of the enclosure with a handheld sensor during tests of both systems did not identify leakage.Conclusion.One HPV generator was more effective than 2 aHP machines for the inactivation ofG. stearothermophilusBIs, and cycle times were faster for the HPV system.


Sign in / Sign up

Export Citation Format

Share Document