Ion-assisted sputter deposition of CdTe layers

1987 ◽  
Vol 65 (8) ◽  
pp. 864-867 ◽  
Author(s):  
S. R. Das ◽  
K. Rajan ◽  
P. Van der Meer ◽  
J. G. Cook

Epitaxial, single-phase CdTe layers have been deposited on a variety of single-crystal substrates, including freshly cleaved KBr and NaCl and polished BaF2, by ion-assisted, planar, rf magnetron sputtering. The substrate temperature and bias were used as independent, operator-controlled process parameters to greatly enhance the degree of orientation in the films and (or) modify the crystallographic form of the deposited layer. Thus, depending primarily on the substrate temperature and bias, the deposited CdTe films exhibited one of several forms: (i) single-phase, highly oriented cubic, (ii) single-phase, highly oriented hexagonal, (iii) two-phase, highly oriented, hexagonal plus cubic or hexagonal plus tetragonal, and (iv) single-phase, epitaxial tetragonal. Compositional analysis revealed no impurities. However, films of all crystallographic phases contained a large density of planar defects such as twins, stacking faults, and low-angle grain boundaries.

Author(s):  
G. Mackiewicz Ludtka

Historically, metals exhibit superplasticity only while forming in a two-phase field because a two-phase microstructure helps ensure a fine, stable grain size. In the U-5.8 Nb alloy, superplastici ty exists for up to 2 h in the single phase field (γ1) at 670°C. This is above the equilibrium monotectoid temperature of 647°C. Utilizing dilatometry, the superplastic (SP) U-5.8 Nb alloy requires superheating to 658°C to initiate the α+γ2 → γ1 transformation at a heating rate of 1.5°C/s. Hence, the U-5.8 Nb alloy exhibits an anomolous superplastic behavior.


2013 ◽  
Vol 35 (3) ◽  
Author(s):  
Tat Thang Nguyen ◽  
Hiroshige Kikura ◽  
Ngoc Hai Duong ◽  
Hideki Murakawa ◽  
Nobuyoshi Tsuzuki

Ultrasonic Velocity Profile (UVP) method for measurement of single-phase and two-phase flow in a vertical pipe has recently been developed in the Laboratory for industrial and Environmental Fluid Dynamics, Institute of Mechanics, VAST. The signal processings of the UVP method include the ultrasonic pulse Doppler method (UDM)and the ultrasonic time-domain cross-correlation (UTDC) method. For two-phase flow, simultaneous measurements of both liquid and gas are enabled by using a multi-wave ultrasonic transducer (multi-wave TDX). The multi-wave TDX is able to emit and receive ultrasound of two different center frequencies of 2 MHz and 8 MHz at the same time and position. 2 MHz frequency with beam diameter 10 mm is exploited for measurement of gas. 8 MHz one with beam diameter 3 mm is used for liquid. Measurements have been carried out for laminar and turbulent single-phase flows and bubbly counter-current two-phase flows in two flow loops using two vertical pipes of 26 mm inner diameter (I.D.) and 50 mm I.D. respectively. Based on the measured results, assessment of each method is clarified. Applicability of each method for different conditions of pipe flow has been tested. Suggestions for application of the two methods have been recommended.


1991 ◽  
Vol 24 (7) ◽  
pp. 59-64 ◽  
Author(s):  
R. W. Szetela

Steady-state models are presented to describe the wastewater treatment process in two activated sludge systems. One of these makes use of a single complete-mix reactor; the other one involves two complete-mix reactors arranged in series. The in-series system is equivalent to what is known as the “two-phase” activated sludge, a concept which is now being launched throughout Poland in conjunction with the PROMLECZ technology under implementation. Analysis of the mathematical models has revealed the following: (1) treatment efficiency, excess sludge production, energy consumption, and the degree of sludge stabilization are identical in the two systems; (2) there exists a technological equivalence of “two-phase” sludge with “single-phase” sludge; (3) the “two-phase” system has no technological advantage over the “single-phase” system.


2009 ◽  
Vol 16 (03) ◽  
pp. 381-386 ◽  
Author(s):  
J. B. CHU ◽  
H. B. ZHU ◽  
Z. A. WANG ◽  
Z. Q. BIAN ◽  
Z. SUN ◽  
...  

Single-phase CuInSe 2 films were grown by high vapor selenization of CuIn alloy precursors within a partially closed graphite box. The CuIn precursors were prepared using Cu x In y alloy targets with different composition rates under low vacuum level by a homemade sputtering system. The Cu and In composition rates of the used targets are 11:9, 10:10, and 9:11, respectively. The metallic precursor films were selenized using a two-step temperature profile, i.e. at 250°C and 400–500°C, respectively. The influence of the temperature at the second selenization step on the quality of the CIS absorbing layers was investigated. The CIS films were characterized by X-ray diffractometry, scanning electron microscopy, energy dispersive X-ray analysis, and Raman spectroscopy. The deposited CIS absorbers selenized at a high temperature of 500°C for 30 min exhibited a single-phase chalcopyrite structure with a preferential orientation in the (112) direction. These layers display uniform, large, and densely packed crystals with a grain size of about 3–5 μm. Cadmium sulfide buffer layer was manufactured by chemical bath deposition method. Bilayers ZnO / ZnO : Al were prepared by RF magnetron sputtering deposition. CIS solar cells with an efficiency of about 6.5% were produced without antireflective films. The method to fabricate CIS solar cells by a combination of the low vacuum sputtering deposition and the graphite box selenization process has provided a simple control process and shown a promising potential for developing high efficient and low-cost CuInSe 2 solar cells.


1967 ◽  
Vol 89 (4) ◽  
pp. 577-586 ◽  
Author(s):  
P. Cooper

A model is developed for analytically determining pump inducer performance in both the single-phase and cavitating flow regimes. An equation of state for vaporizing flow is used in an approximate, three-dimensional analysis of the flow field. The method accounts for losses and yields internal distributions of fluid pressure, velocity, and density together with the resulting overall efficiency and pressure rise. The results of calculated performance of two sample inducers are presented. Comparison with recent theory for fluid thermal effects on suction head requirements is made with the aid of a resulting dimensionless vaporization parameter.


2010 ◽  
Vol 132 (4) ◽  
Author(s):  
Yoon Jo Kim ◽  
Yogendra K. Joshi ◽  
Andrei G. Fedorov ◽  
Young-Joon Lee ◽  
Sung-Kyu Lim

It is now widely recognized that the three-dimensional (3D) system integration is a key enabling technology to achieve the performance needs of future microprocessor integrated circuits (ICs). To provide modular thermal management in 3D-stacked ICs, the interlayer microfluidic cooling scheme is adopted and analyzed in this study focusing on a single cooling layer performance. The effects of cooling mode (single-phase versus phase-change) and stack/layer geometry on thermal management performance are quantitatively analyzed, and implications on the through-silicon-via scaling and electrical interconnect congestion are discussed. Also, the thermal and hydraulic performance of several two-phase refrigerants is discussed in comparison with single-phase cooling. The results show that the large internal pressure and the pumping pressure drop are significant limiting factors, along with significant mass flow rate maldistribution due to the presence of hot-spots. Nevertheless, two-phase cooling using R123 and R245ca refrigerants yields superior performance to single-phase cooling for the hot-spot fluxes approaching ∼300 W/cm2. In general, a hybrid cooling scheme with a dedicated approach to the hot-spot thermal management should greatly improve the two-phase cooling system performance and reliability by enabling a cooling-load-matched thermal design and by suppressing the mass flow rate maldistribution within the cooling layer.


2014 ◽  
Vol 986-987 ◽  
pp. 330-333
Author(s):  
Ding Jun Wen ◽  
Xiu Bin Zhang ◽  
Hong Gang Chen ◽  
Feng Jiang ◽  
Ya Ming Sun

The overvoltage calculation of 750kV transmission line with series compensation has great significance on the design, insulation coordination and protection of the line. In this paper, a transient model of 750kV power transmission system with series compensation is established. Effects of different capacity on no-load capacitive rise overvoltage, single-phase grounding overvoltage, two-phase grounding overvoltage are calculated. Secondary arc current and recovery voltage of different series compensation capacity in single-phase grounding is also calculated.


Sign in / Sign up

Export Citation Format

Share Document