A new method for the fractionation of human plasma high density lipoprotein
Keyword(s):
We have devised a new method for the fractionation of human plasma high density lipoprotein (HDL). The HDL was chromatographed on DEAE-agarose columns using a continuous gradient of 0.06–0.15 M NaCl. The elution pattern obtained showed three phases, each with differing peptide composition. Examination of the three subfractions showed that each contained both apo A-I and apo A-II, but indifferent proportions. Subfraction 1 contained noapoC-II orC-III-1 and only a trace of apo C-III-2, subfraction 2 contained apo C-II and C-III-1 but no C-III-2, while subfraction 3 contained considerable apo C-III-2 with only traces of apo C-II or C-III-1.
1978 ◽
Vol 253
(22)
◽
pp. 8034-8041
◽
1987 ◽
Vol 28
(6)
◽
pp. 719-732
◽
1981 ◽
Vol 256
(19)
◽
pp. 9849-9854
◽
2016 ◽
Vol 1861
(11)
◽
pp. 1787-1795
1980 ◽
Vol 617
(3)
◽
pp. 480-488
◽
1982 ◽
Vol 712
(3)
◽
pp. 444-452
◽
1977 ◽
Vol 75
(1)
◽
pp. 117-124
◽
1972 ◽
Vol 49
(6)
◽
pp. 1444-1451
◽