NOTES ON THE APPLICATION OF THE HERSCH GALVANIC OXYGEN CELL TO MEASUREMENT OF BLOOD OXYGEN CONTENT AND TENSION

1961 ◽  
Vol 39 (6) ◽  
pp. 991-999 ◽  
Author(s):  
D. V. Bates ◽  
E. V. Harkness

A number of galvanic oxygen cells have been built to the design of Hersch (1). Factors influencing the sensitivity of this type of cell to oxygen have been studied, and the potentialities of the cells in the analysis of small gas samples have been explored. With the cell used in the manner described, analysis of 105 samples of air of an average volume of 0.001 ml showed the standard deviation of the percentage of oxygen to be 0.9%. The mean oxygen percentage of these samples was correct at 20.8%. These cells were found to be suitable for the analysis of the oxygen contained in very small blood samples, and the method described probably offers the most precise technique there is for the determination of the oxygen saturation of 0.002 ml of blood. By bubble equilibration techniques, the cell may also be used to determine the oxygen tension of blood samples in the range 0–200 mm Hg.

1983 ◽  
Vol 104 (1) ◽  
pp. 1-5 ◽  
Author(s):  
J. Leppäluoto ◽  
L. Rönnberg ◽  
P. Ylöstalo

Abstract. Seven patients suffering from severe endometriosis were treated with danazol 200 mg × 3 daily for 6 months. Clinical symptoms were alleviated and menses disappeared in response to the treatment. After cessation of the treatment the menstrual bleedings returned in 1–3 months. Blood samples for determination of gonadotrophins, prolactin (Prl), oestradiol (E2), progesterone, thyroid hormones and thyrotrophin in radioimmunoassays were taken and a combined TRF and LRF test carried out in the follicular phase before treatment, at the 6th month of treatment and after reappearance of the first menses. There were no statistically significant changes in the basal levels of serum FSH, LH or TSH during the danazol treatment. Neither was there any change in episodic secretions of FSH, LH or Prl, as determined by the mean coefficients of variation of the hormone levels in seven consecutive samples taken at 20 min intervals. On the other hand, serum E2, Prl and thyroid hormone levels were significantly decreased in the 6th month of treatment. In the TRF-LRF test the responses of serum FSH and LH were significantly higher and those of serum Prl and TSH significantly lower during danazol treatment than before. Prl responses remained lowered after the treatment. It appears that low serum oestrogen levels, induced by the danazol treatment, sensitize the pituitary gonadotrophs to exogenous LRF, but make the sensitivity of thyrotrophs and lactotrophs lower to exogenous TRF. These results thus indicate that danazol does not make the pituitary gonadotrophs insensitive to LRF, but danazol may rather inhibit the secretion of hypothalamic LRF.


1994 ◽  
Vol 13 (2) ◽  
pp. 131-134 ◽  
Author(s):  
Lars Aabakken ◽  
Kjerstin S. Johansen ◽  
Else-Berit Rydningen ◽  
Jan E. Bredesen ◽  
Steinar Øvrebø ◽  
...  

1 Osmolal and anion gaps are helpful in the diagnosis and evaluation of intoxications with methanol and ethylene glycol. Reported reference values for osmolal gap and anion gap are -1 (± 6) mosm kg-1 H2O and 16 (± 2) mmol I -1, respectively. However, we have repeatedly found unexplained increased gaps in patients admitted to our department, and the relevance of the established reference values has been questioned. 2 Osmolal and anion gaps were determined in an unselected population of patients consecutively admitted to an emergency medical department. In the case of unexplained gaps, the blood samples were analysed with respect to the presence of alcohols and organic acids. 3 We included all accessible patients admitted during 14 days. Appropriate blood samples were obtained in 177 patients (88 male, 89 female), with a mean age of 65 years (range 17-94). 4 The mean and (standard deviation) for osmolal and anion gaps in our material were 5.2 mosm kg-1 H2O (7.0) and 12.9 mmol/l (4.2). Neither methanol nor ethylene-glycol was detected in serum from any patients. Small amounts of ethanol were found in 5 patients, and high lactate levels explained in part the most extensively increased anion gaps. However, the calculated analytical standard deviation accounted entirely for the variation in our material, and we suggest that the present reference values be adjusted.


2015 ◽  
Vol 27 (01) ◽  
pp. 1550004 ◽  
Author(s):  
Audrey K. C. Huong ◽  
Xavier T. I. Ngu

We present the use of Extended Modified Lambert–Beer model for optical monitoring of mean blood oxygen saturation ( S m O 2) via a fitting procedure. This work focuses on the absorption characteristics of hemoglobin derivatives in the wavelength range of 520–600 nm to give the best estimates of S m O 2. The study of the feasibility of applying this analytic method to skin oximetry is via spectroscopy data collected from fingertips of four healthy volunteers both at rest and during arterial blood occlusion condition. The results revealed a decrease in the mean of mean and standard deviation of S m O 2 value of fingertips from 94.5 ± 2.19% when volunteers were at rest to 56.76 ± 5.8% during the arterial blood occlusion measurement. The larger variation in the value estimated for blood occlusion condition could be a result of differences in volunteers' physical fitness and hypertension status. These estimated S m O 2 values agreed reasonably well with the value reported in most of the previous studies. This work concluded that the proposed technique can potentially be used as a complementary technique to clinical assessment of skin grafts and burnt skin.


1985 ◽  
Vol 31 (5) ◽  
pp. 750-753 ◽  
Author(s):  
N Hata ◽  
K Miyai ◽  
M Ito ◽  
Y Endo ◽  
Y Iijimi ◽  
...  

Abstract We describe a double-antibody enzyme immunoassay for determination of free thyroxin (FT4) in dried blood samples on filter paper, with use of a T4-beta-D-galactosidase complex. The measurable range of FT4 concentration in two 3-mm blood discs, each of which contained about 2.7 microL of blood, was 1.9 to 93 ng/L, as determined by comparison with concentrations of FT4 in known serum standards. FT4 in blood samples dried on filter paper was stable for at least four weeks when kept dry at -20 degrees C, room temperature, or 37 degrees C. The mean coefficients of variation were 7.6% (within assay) and 6.4% (between assays). Results for FT4 by this method correlated well with those for serum determined by radioimmunoassay (r = 0.98). The proposed method can be used to differentiate persons with hyper- and hypothyroidism from normal subjects and those with abnormal concentrations of thyroxin-binding globulin. The procedure seems suited for screening studies.


1987 ◽  
Vol 70 (4) ◽  
pp. 664-667
Author(s):  
Tee-Siaw Koh

Abstract Fifty-one laboratories from 14 countries participated in a survey on the determination of selenium (Se) in 8 bovine blood samples with Se concentrations ranging from 0.2 μmol/L (0.016 μg/mL) to 14 μmol/L (1.1 μg/mL). The methods used (and the percentage of participants using each method) were fiuorometry (61), hydride-generation atomic absorption spectrophotometry (AAS) (23), graphitefurnace AAS (6), gas chromatography (4), neutron activation analysis (4), and X-ray fiuorometry (2). There was little difference in the mean Se results obtained by fiuorometry or hydride-generation AAS (P > 0.05). Mean intralaboratory coefficients of variation (CVs) from known replicates ranged from 4 to 14% for all samples. Interlaboratory CVs were related to blood Se concentration and increased to 55% at Se levels below 0.4 μmol/L (0.032 μg/mL). Laboratories that used quality control (QC) schemes had lower interlaboratory CVs than those that did not, but the advantage began to diminish at blood Se concentration below 0.4 μmol/L (0.032 μg/mL). The high interlaboratory CVs, coupled with the false assurance from the low intralaboratory CVs and the ineffectiveness of the QC schemes at blood Se concentrations below 0.4 μmol/L (0.032 μg/mL), are of concern in diagnosis of marginal Se deficiency in livestock where the concentrations of interest are in the range 0.15-0.5 μmol/L (0.012-0.039 μg/mL).


1973 ◽  
Vol 56 (5) ◽  
pp. 1164-1172
Author(s):  
Milan Ihnat ◽  
Robert J Westerby ◽  
Israel Hoffman

Abstract The distillation-spectrophotometric method of Hoffman for determining maleic hydrazide has been modified to include a double distillation and was applied to the determination of 1–30 ppm maleic hydrazide residues in tobacco and vegetables. Recoveries of 1–23 μg added maleic hydrazide were independent of weight of maleic hydrazide, but did depend on sample and sample weight. The following recoveries were obtained from 0.5 g sample: pipe tobacco, 84%; commercially dehydrated potato, 83%; cigar tobacco, 81%; dried potato, 76%; fluecured tobacco, 73%; dried carrot, 71%. In the absence of sample, the recovery was 82%. When appropriate standard curves were used, maleic hydrazide levels determined in tobacco samples were essentially independent of sample weight in the range 0.1–3 g. The mean relative standard deviation for a variety of field-treated and fortified tobacco samples containing 1–28 ppm maleic hydrazide was 3%. The precision and sensitivity of this procedure seem to be substantial improvements over official method 29.111–29.117. It is recommended that the present method be subjected to a collaborative study.


Blood ◽  
1987 ◽  
Vol 69 (1) ◽  
pp. 316-323 ◽  
Author(s):  
MP Sorette ◽  
MG Lavenant ◽  
MR Clark

Abstract In an effort to study the rheologic effects of small amounts of hemoglobin S (HbS) polymer in sickle red cells, we have used the ektacytometer, a laser diffraction couette viscometer, to measure sickle cell deformability as a function of oxygen tension. Sickle cell populations of defined intracellular hemoglobin concentration (MCHC) were isolated using Stractan density gradients and were resuspended in buffered polyvinylpyrrolidone solutions for deformability measurements. Using a gas-porous, hollow fiber gas exchange system to establish a linear gradient in oxygen tension, deformability was measured over a pO2 range of 76 to 0 mm Hg. Parallel spectroscopic determinations of oxygen saturation permitted determination of cell deformability as a function of oxygen saturation for each discrete MCHC population. From these measurements the level of oxygen saturation at which a loss in cell deformability was first detected could be defined. Then, using the data of Noguchi and Schecter, the amount of polymerized HbS in the cells at that defined level of oxygen saturation was estimated. The results of this analysis suggested that the quantity of polymer that caused a detectable loss in cell deformability increased with increasing MCHC. In addition, for MCHC above 30 g/dL, this represented a substantial fraction of the total HbS in the cell.


1974 ◽  
Vol 57 (2) ◽  
pp. 368-372 ◽  
Author(s):  
Milan Ihnat

Abstract A fluorometric method using 2,3-diaminonaphthalene for estimating selenium has been evaluated with regard to its applicability to food samples. Charring of the sample during digestion appeared to result in losses of native and added selenium from some samples, so a modified wet digestion procedure was introduced. Digestion first in nitric acid followed by a mixture of nitric-perchloric-sulfuric acids substantially reduced the incidence of sample charring for a variety of foods. The mean apparent recovery of selenium added as selenite or selenate at 100 and 500 ng levels to 0.1 and 1.0 g corn cereal, skim milk powder, and meat and 0.1 g fish was 101.0%; the actual recovery of the same levels of selenium from standard solutions was 96.6%. For a variety of samples containing 5—750 ng native or added selenium, the standard deviation as 4.7 + 1.95 X 10-2W ng, where W = ng selenium in the sample taken for analysis. The relative standard deviation (RSD) as a function of selenium weight (ng) was 50% (10), 6.7% (100), 4.3% (200), 3.1% (400), 2.7% (600), and 2.5% (800). The detection limit (weight of selenium at which RSD = 50%) was 10 ng at a mean blank level of 25 ng.


1959 ◽  
Vol 32 (3_ts) ◽  
pp. 285-293 ◽  
Author(s):  
S. Raymond Gambino ◽  
Beidatsch Ruth ◽  
Patricia Bethe ◽  
Joan Willard ◽  
Walter Thiede

Sign in / Sign up

Export Citation Format

Share Document