Characterization of Nova Scotia surface waters and treatment options for removal of colour and trihalomethane precursors

1996 ◽  
Vol 23 (6) ◽  
pp. 1316-1325 ◽  
Author(s):  
D. H. Waller ◽  
M. J. MacPhee ◽  
P. W. Prendiville ◽  
R. F. McCurdy ◽  
A. W. Gates ◽  
...  

This paper provides an overview of the results of a study undertaken to provide a basis for predesign evaluation of the effectiveness of options for treatment of municipal surface waters in the province of Nova Scotia. Seasonal samples of raw water were obtained from the fall of 1992 through the fall of 1993 from five sites. Results were compared with a Nova Scotia Department of Health data base of randomly collected samples. For project samples, strong relationships were evident between raw water total organic carbon (TOC) and both colour and trihalomethane formation potential. Laboratory batch tests, supported by plant results, indicated that percentage removals of TOC increase with raw water TOC, and that settling-filtration was more effective than direct filtration for waters with higher raw TOC concentrations. Results of solids settling tests were consistent with TOC results. A treatment optimized for TOC removal also ensured removal of colour. TOC removals by dissolved air flotation followed by filtration exceeded removals by direct filtration or settling-filtration, based on laboratory bench tests, particularly at sites with higher values of raw TOC. Colour removal by dissolved air flotation was consistently higher at all sites. Key words: enhanced coagulation, trihalomethane precursors, total organic carbon, surface water treatment, dissolved air flotation.

2004 ◽  
Vol 50 (12) ◽  
pp. 245-253 ◽  
Author(s):  
S.B. Kwon ◽  
H.W. Ahn ◽  
C.J. Ahn ◽  
C.K. Wang

A DAF (Dissolved-Air-Flotation) process has been designed considering raw water quality characteristics in Korea. Although direct filtration is usually operated, DAF is operated when freshwater algae blooms occur or raw water turbidity becomes high. Pre-sedimentation is operated in case when the raw water turbidity is very high due to rainstorms. A main feature of this plant is that the operation mode can be changed (controlled) based on the characteristics of the raw water to optimize the effluent quality and the operation costs. Treatment capacity (surface loading rate) and efficiency of DAF was found to be better than the conventional sedimentation process. Moreover, low-density particles (algae and alum flocs) are easily separated while the removal of them by sedimentation is more difficult. One of the main concerns for DAF operation is a high raw water turbidity. DAF is not adequate for raw water, which is more turbid than 100 NTU. In order to avoid this problem, pre-sedimentation basins are installed in the DAF plant to decrease the turbidity of the DAF inflow. For simulation of the actual operation, bench and full-scale tests were performed for highly turbid water conditions. Consequently, it is suggested that pre-sedimentation with optimum coagulation prior to DAF is the appropriate treatment scheme.


2001 ◽  
Vol 43 (8) ◽  
pp. 43-49 ◽  
Author(s):  
M. A. P. Raeli ◽  
M. Marchetto

This paper presents the results of an experimental investigation about the performance of a horizontal flow high-rate pilot scale Dissolved Air Flotation (HRDAF) unit containing inclined parallel plates for treating a coloured and low turbidity raw water. Experiments were performed with the DAF unit in order to verify the influence on flotation of : (i) the water velocity (Vh) between the plates, in the range 18 to 96.5 cm.min−1 with corresponding Reynolds numbers between 240 and 1060; (ii) the supplied air (S*) value ranging from 2.2 to 8.5 g of air/m3 of water ; (iii) the angle of the plates (60° or 70°). The best pilot plant operational condition was obtained applying only 4.0 g/m3 (S*) with Vh around 18 cm.min−1 for treatment of water coagulated with a Al2(SO4)3 dosage of 40 mg.l−1. In these conditions, the unit presented very good removal efficiencies of colour (90%, residual of 10 uC), turbidity (88%, residual of 0.8 NTU ) and TSS (94%, residual of 1.8 mg.l−1). Furthermore, the unit could operate at higher Vh values up to 76 cm.min−1 and still present good results. The DAF unit thus behaved as a high rate unit presenting good performance with low air requirement.


2008 ◽  
Vol 3 (3) ◽  
Author(s):  
Mohammad Hassan Mahmoodian ◽  
Mohammad Mehdi Amin ◽  
Mohammad Reza Shahmansouri ◽  
Mohammad Ghasemian

Recovering spent filter backwash water is currently receiving a great deal of attention. EPA published the Filter Backwash-Recycling Rule (FBRR) in 2001. Recycle stream may contain significant concentration of pathogens, such as, cryptosporidium and Giardia. Dissolved Air Flotation (DAF) was investigated as a possible technology alternative to simple or advanced sedimentation technology. In this study with using a pilot of DAF effluent turbidities of >20NTU could be easily obtained, when raw water turbidities were in excess of 800 NTU. Chemical requirements were low with only a single low dose of polyaluminium chloride (PACl) required binding the floc particles to form a solids matrix suitable for flotation. The results showed that the efficiency of continuous flow DAF with using PACl as coagulant for removal of Turbidity, COD, HPC, SS and MPN were 97, 72, 75, 95 and 100 percent, respectively. The statistical analyses indicated that the optimum saturation pressure is 4-5 atm, during recycle rate of 20-25 percent. The removal efficiencies of turbidity and bacteria in coagulation with sedimentation were reported up to 70 and 65 percent, while in this study using DAF with coagulant PACl could remove turbidity, COD, SS and bacterial up to 97,72, 95 and, 72 percent respectively.


2001 ◽  
Author(s):  
◽  
Rachigan Rajagopaul

Historically inorganic coagulants were the coagulants of choice for OAF treatment of potable water. Water treatment practitioners using OAF technology preferred ferric chloride, an inorganic coagulant. Ferric chloride formed light, floatable floes at relatively low flocculation intensities and detention times. The inorganic coagulant was also more forgiving during incidents of overdosing and raw water and pH variability


2004 ◽  
Vol 4 (5-6) ◽  
pp. 35-41
Author(s):  
X. Zhang ◽  
S. Zhang ◽  
Y. Liu

Compact flofilter of dissolved air flotation and GAC deep bed filtration is a good integrated procedure, having the following characteristics: flotation and filtration are integrated in one tank, the flotation unit is above the filtration unit, filtration is GAC deep bed, and conventional and advanced treatments are integrated in one tank. During the treatment of algae-laden raw water with compact flofilter of dissolved air flotation and GAC deep bed filtration, the general performance was good: the outlet algae-count was 1.21×105–1.26×106 cell/l, the average removal of algae was 95.4%, the outlet chl-a was 0.68 μg/l, the removal of chl-a was 92.2%, the outlet turbidity was 0.16–0.20 NTU, the outlet had no odor, the outlet color was 3, the removal of color was 86.4%, the outlet Al-residual was 0.011 mg/l. Good removal of organics can be achieved: the average removal of UV254 was 54.3%, the outlet UV254 was 0.016–0.018 cm−1, the removal of DOC was 29.6%, the outlet DOC was 1.608 mg/l, the removal of BDOC was 42.6%, the outlet BDOC was 0.120 mg/l, the removal of AOC was 72.2%, the outlet AOC was 52 μg/l. Filter run period and UFRV were 36 h and 504 m3/m2. The results show that flofilter is a good alternative process for conventional treatment plus GAC adsorption.


1995 ◽  
Vol 31 (3-4) ◽  
pp. 149-157 ◽  
Author(s):  
Jan van Puffelen ◽  
Paul J. Buijs ◽  
Peter N. A. M. Nuhn ◽  
Wim A. M. Hijnen

This paper reviews the experience the drinking water companies in The Netherlands have gained in the last twenty years in the field of dissolved air flotation. An overview of the Dutch flotation plants with their individual objectives is presented. The efficiency of flotation towards the removal of different parameters, such as turbidity, organic matter and micro-organisms is good, which is illustrated by data from the water companies. Both in the past and at present water companies compare flotation to other floc separation techniques, such as sedimentation or direct filtration. Specially for waters with (relative) low turbidity and high chlorophyll-a content, flotation proved (in combination with rapid sand filtration) to be very effective. The efficiency of the flotation process has been improved by the development of different nozzle-types. Some of these types are described here, each with their advantages and disadvantages. In general dissolved air flotation has proved to be as sturdy and reliable as sedimentation techniques, such as lamellae settling.


1995 ◽  
Vol 31 (3-4) ◽  
pp. 63-71 ◽  
Author(s):  
Donald Q. Bunker ◽  
James K. Edzwald ◽  
Jan Dahlquist ◽  
Lars Gillberg

Pretreatment considerations of coagulant selection, flocculation time and flocculation mixing intensity were studied for two different water supply types, aquatic humic and non-aquatic humic waters of low turbidity. Alum, ferric salts, and various polyaluminium chlorides (PACs) with different chemical properties were all effective in dissolved air flotation (DAF) when used under favorable conditions of dosage, pH, and flocculation time. A stoichiometry was found for the aluminium coagulants between coagulant dose and raw water DOC. Si and sulfate PACs were effective in treating cold waters with short flocculation times of 2.5 to 5 minutes. Flotation performance improved slightly with increasing flocculation mixing intensity. The results suggest that flocculation tanks be designed to produce strong, “pinpoint” size floc particles.


1995 ◽  
Vol 31 (3-4) ◽  
pp. 113-124 ◽  
Author(s):  
C. Ferguson ◽  
G. S. Logsdon ◽  
D. Curley

Direct filtration with and without pre-ozone, and dissolved air flotation and filtration were evaluated for clarification of high quality reservoir water in Greenville, South Carolina, USA. Goals of the study included production of low turbidity filtered water and control of algae, iron and manganese, and disinfection by-product precursors. The dissolved air flotation treatment train gave much longer filter runs than direct filtration, when both processes met the 0.10 NTU goal for filtered water quality. Use of pre-ozone was beneficial for direct filtration. Removal of TOC, DBP precursors, and iron and manganese were similar for both processes.


2001 ◽  
Vol 43 (8) ◽  
pp. 27-34 ◽  
Author(s):  
S. Kempeneers ◽  
F. Van Menxel ◽  
L. Gille

In April 1990 Antwerpse Waterwerken brought a new DAF-plant into operation at the production centre Notmeir-Walem. The flotation unit, which has a capacity of 200,000 m3/d, was integrated in one of the two existing treatment lines. Its main objective was to eliminate the important raw water quality fluctuations caused by increasing algal growths. During the past ten years several optimisation studies were carried out which resulted in a further simplification of operation and mechanical design. This paper will focus mainly on the integration of dissolved air flotation in the entire treatment line, the consequences on the dual layer filtration and the operational experience and information gathered during the past decade.


1995 ◽  
Vol 31 (3-4) ◽  
pp. 83-92 ◽  
Author(s):  
B. A. Johnson ◽  
B. Gong ◽  
W. Bellamy ◽  
T. Tran

The Massachusetts Water Resources Authority (MWRA) supplies water to 2.5 million people in Eastern Massachusetts. Currently, the surface water supply is unfiltered. To determine the best way to comply with the Safe Drinking Water Act Amendments (SDWA), the MWRA initiated watershed protection and pilot treatment studies. This paper summarizes the major findings of the pilot treatment study. In particular, it compares the performance of dissolved air flotation with that of inline filtration, direct filtration, and contact adsorption clarification. Each process was evaluated for turbidity removal, filter production, particle reduction, disinfection byproducts, effect of ozonation, and coagulants. As a result of the piloting, a treatment process train consisting of dissolved air flotation, ozone, biological filtration, and chloramination was recommended.


Sign in / Sign up

Export Citation Format

Share Document