Dynamic analysis of an unsymmetrical high rise building

1976 ◽  
Vol 3 (1) ◽  
pp. 107-118
Author(s):  
W. K. Tso ◽  
R. Bergmann

A complete time history response dynamic analysis is carried out to establish the design seismic loading for the Harbour Centre building in Vancouver. The building has an elevated observation deck and restaurant offset from the centre of the structure. The paper describes the steps and considerations involved in the dynamic analysis such as the dynamic modelling of the structure, the choice of input ground records and the interpretation of the computed results. Whenever possible, the calculated values are compared with the 1975 National Building Code of Canada requirements to provide a proper perspective of the various approaches in establishing design loads for this building.

1998 ◽  
Vol 25 (2) ◽  
pp. 342-352 ◽  
Author(s):  
André Filiatrault ◽  
Éric Lachapelle ◽  
Patrick Lamontagne

This paper is the second of two companion papers on the evaluation of the level of protection offered by ductile and nominally ductile reinforced concrete structures. In the first paper, experimental results obtained from shake table tests of two half-scale reinforced concrete moment resisting frames were reported. The first structure was designed as a ductile frame (force reduction factor R = 4) according to current Canadian standards; and the second structure incorporated only nominally ductile details (R = 2). This second paper deals with the dynamic modelling of the two structures. A simple nonlinear time-history dynamic analysis model is presented and its predictions are compared with the shake table test results. It is shown that inelastic deformations in beam-column joints have a major influence on the seismic response of the structures. Approximate modelling of these joint deformations, based on equivalent rotational springs, can provide a good correlation between numerical and experimental results.Key words: dynamic analysis, moment resisting frames, earthquakes, reinforced concrete, seismic.


In this paper, the optimum or suitable location of shear wall in a high rise irregular shaped building is determined. The criteria of choosing suitable location are well mentioned with suitable examples. We have tested several models in dynamic analysis with the help of ETABS ver. 16. Both Time History and Response Spectrum Methods are performed in the analysis. The paper clearly specifies the causes of torsion in a high rise building as well as it also specifies the ways in which we can control the torsion and storey displacement with the help of shear wall in the high rise buildings.


The response of any building during seismic loading conditions might be affected by several factors, the horizontal torsion effect which generated by the eccentricity between centre of mass and centre of rigidity has conspicuous impact on the total response of building however, in many of the modern codes this influence is introduced by adopting the accidental eccentricity (AE) concept. In this paper analytical evaluation was done to assess the impact of the accidental torsion on high-rise structures with asymmetrical and symmetrical plan configurations in order to estimate the horizontal torsion effects for both regular and irregular structures during a high-intensity earthquake. The linear-static method, linear-dynamic (RS) method and time history method are the followed procedures for analysing the models, whilst the provisions of the considered codes are the Indian standard provisions and uniform building code 97 provisions, three different conditions were applied the first applying the seismic later load without accidentaleccentricity (AE), the second case is assuming %5 of (AE) which is worldwide presupposed value in many of seismic codes, where the third condition is adapting an accidental-eccentricity (AE) calculated according to the selected seismic codes. ETABS 2016 Software was utilized for analysing all models.


2003 ◽  
Vol 30 (2) ◽  
pp. 338-359 ◽  
Author(s):  
Murat Saatcioglu ◽  
JagMohan Humar

The proposed 2005 edition of the National Building Code of Canada specifies dynamic analysis as the preferred method for computing seismic design forces and deflections, while maintaining the equivalent static force method for areas of low seismicity and for buildings with certain height limitations. Dynamic analysis procedures are categorized as either linear (elastic) dynamic analysis, consisting of the elastic modal response spectrum method or the numerical integration linear time history method, or nonlinear (inelastic) response history analysis. While both linear and nonlinear analyses require careful analytical modelling, the latter requires additional considerations for proper simulation of hysteretic response and necessitates a special study that involves detailed review of design and supporting analyses by an independent team of engineers. The paper provides an overview of dynamic analysis procedures for use in seismic design, with discussions on mathematical modelling of structures, structural elements, and hysteretic response. A discussion of the determination of structural period to be used in association with the equivalent static force method is presented.Key words: dynamic analysis, earthquake engineering, elastic analysis, fundamental period, hysteretic modelling, inelastic analysis, National Building Code of Canada, seismic design, structural analysis, structural design.


2013 ◽  
Vol 671-674 ◽  
pp. 1341-1345
Author(s):  
Jing Wei Nie ◽  
Hong Bing Liu ◽  
Zhao Fang

The research on elastic-plastic dynamic response analysis of the high-rise building with transfer storey is carried out under different earthquake record inputs.The displacement time- history response of the top floor and the transfer storey, also the displacement envelope diagram and interlayer drift angle envelope diagram are obtained.Theoretical reference for the design of the weak layer is provided.


1976 ◽  
Vol 3 (1) ◽  
pp. 11-19
Author(s):  
W. K. Tso ◽  
B. P. Guru

A statistical study has been done to investigate (i) the variation of spectral responses of structures due to artificially generated earthquake records with identical statistical properties, (ii) the effect of duration of strong shaking phase of artificial earthquakes on the response of structures, and (iii) the number of earthquake records needed for time-history response analysis of a structure in a seismic region. The results indicate that the flexible structures are more sensitive to the inherent statistical variations among statistically identical earthquake records. Consequently several records must be used for time-history response analysis. A sample of eight or more records appear to provide a good estimate of mean maximum response. The duration of strong shaking can significantly affect the maximum response. Based on the results, it is suggested that for the purpose of estimating peak response, the strong shaking duration of the input earthquake motion should be at least four times the natural period of the structure. The maximum responses due to statistically identical ground motion records are observed to fit approximately the type 1 extreme value distribution. Thus, it is rationally possible to choose a design value based on the mean, standard deviation of the spectral response values and tolerable probability of exceedance.


2013 ◽  
Vol 788 ◽  
pp. 558-561
Author(s):  
Jian Qiang Wang ◽  
Wen Tao Ma ◽  
Min Jing Ma

Steel reinforced concrete composite structure which apply in the high-rise buildings, not only save steel, but also have excellent properties in fire prevention, anti-corrosion, and seismic performance, and improve the speed of construction, economic efficiency.This thesis based on the analyse of a steel reinforced concrete composite structure tower and the domestic and foreign experts study use Finite Element Analysis software SAP2000 analyze the dynamic Performance of the structure to draw the inherent vibration period and frequency of the structure. The structure is analyzed to obtain its deformation with different height of the structural elements under a small earthquake. Structure and component in elastic stage when suffur a small earthquake. Using the mode decomposition response spectrum method and method of linear time history analysis, the maximum horizontal displacements of the structural layer, the maximum inter-story displacement and the maximum inter-story displacement angle is obtained to see if the results within a predetermined range.