Stepped chutes lined with wedge-shaped concrete blocks: hydrodynamic pressures on blocks and stability analysis

2011 ◽  
Vol 38 (3) ◽  
pp. 338-349 ◽  
Author(s):  
António T. Relvas ◽  
António N. Pinheiro

The use of wedge-shaped concrete block overlays to protect embankments subject to flows with relatively high velocities is an idea dating from the late 1960s. Subsequent studies addressed the block stability and design, with or without drainage layer underneath, and the flow characteristics. One aspect still lacking systematic research is the block stability considering the influence of the drainage layer and of the uplift pressure beneath the blocks. The stability of blocks located in the training walls of a trapezoidal cross section has never been investigated, although this type of section is expected when installing a concrete block overlay over embankments. The present study addresses this aspect, using a relatively large facility where the blocks are laid on a drainage layer over an embankment artificially saturated, thus intending to simulate a concrete block spillway installed over a compacted homogeneous earth dam. Data collected both in a trapezoidal flume and in a rectangular flume are is analyzed, together with other authors’ data for this type of stepped overlay. The inherent hydrodynamic stability is verified. Experiments with hydraulic jump formation over the blocks at the end of the flume also showed block stability.

2011 ◽  
Vol 213 ◽  
pp. 409-413
Author(s):  
Xiao Lei Zhang ◽  
Jun Jie Li ◽  
Zun Xin Huang ◽  
Yong Hao Chen

A drainage experiment on chain concrete blocks with ecological function has carried out to study their mechanical properties. This paper presents the stress condition, stability and the effect of infilling gravels, and analyzes the anti-scour capability of the chain concrete block revetment, finally provides some usage suggestions. The results indicate that: The stability and anti-scour capability are good after the blocks are filled with gravels. The infilling gravels are scoured and a certain slope is formed. It is suggested to consider the residual volume of the gravels to save investments. The average thickness of the cushion is suggested to be 15cm to keep the dry stones smooth. The new type chain concrete blocks have such advantages as high anti-shear stress and stability, well permeability, ecological protection, easy construction and low cost.


Author(s):  
D. J. Kwag ◽  
I. H. Cho ◽  
S. Bang ◽  
Y. Cho

A floating breakwater was built in Southern Korea. Four separate floating breakwater units were moored to ten deeply buried embedded suction anchors. The embedded suction anchor is a type of permanent offshore foundation installed by a suction pile. The cross section of the embedded suction anchor is circular, with its diameter being equal to that of the suction pile that is used to drive it into the seafloor. Vertical flanges are typically added along the circumference to increase its resistance. Determination of the loading capacity and the dimensions of embedded suction anchors are described. Details of the construction and installation of embedded suction anchors, as well as the field proof test results are also discussed. A total of ten steel embedded suction anchors were manufactured and installed successfully. Installation of embedded suction anchors was accomplished with a suction pile attached to its top. Subsequent proof tests validated the design loading capacity of embedded suction anchors. A floating breakwater consisted of four separate units was constructed. Initially, embedded deadweight concrete blocks were considered to moor the floating breakwater units. Later, however, embedded suction anchors replaced the concrete block anchors due to numerous environmental constraints. Each floating unit was anchored with four embedded suction anchors. Field proof tests indicate that the embedded suction anchors can provide necessary resistance against the anticipated wind and wave forces.


Author(s):  
Douglas L. Dorset

A variety of linear chain materials exist as polydisperse systems which are difficultly purified. The stability of continuous binary solid solutions assume that the Gibbs free energy of the solution is lower than that of either crystal component, a condition which includes such factors as relative molecular sizes and shapes and perhaps the symmetry of the pure component crystal structures.Although extensive studies of n-alkane miscibility have been carried out via powder X-ray diffraction of bulk samples we have begun to examine binary systems as single crystals, taking advantage of the well-known enhanced scattering cross section of matter for electrons and also the favorable projection of a paraffin crystal structure posited by epitaxial crystallization of such samples on organic substrates such as benzoic acid.


2018 ◽  
Vol 6 (3) ◽  
pp. 20-28
Author(s):  
Faisal Al Tabatabaie ◽  
Dhabia Sabeeh Al Waily

The use of cutoffs underneath the hydraulic structures is considered a safe solution to ensure the stability of hydraulic structure against uplift pressure and piping phenomenon in addition to the sliding and overturning forces of the water. These cutoffs are used at critical sections underneath the floor of hydraulic structure to substitute with their depths the horizontal lengths of the creep line of the hydraulic structure base. In this paper, the experimental method- by using electrical analogue model- was carried out to plot the flow net and study the efficiency of the front and rear faces of the cutoffs for dissipating the potential energy of the percolating water underneath the floor of hydraulic structure. An electrical analogue model which was used in this study consists of twenty five models with different depths of upstream and downstream cutoffs. After plotting the flow net for all models, it is concluded that the efficiency of the inner sides are less than that of the outer sides which were investigated before in this topic of this work that both faces reduction values in the uplift pressure are considered the same, where the efficiency of the outer face of upstream cutoff is (70.35) % and for the inner face is (29.64)%, while for the downstream cutoff the efficiency for the outer face is (76.21)% and for the inner face is (23.79)% .


Materials ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4174
Author(s):  
André M. Santos ◽  
Ângelo J. Costa e Silva ◽  
João M. F. Mota ◽  
João M. P. Q. Delgado ◽  
Fernando A. N. Silva ◽  
...  

The understanding of the mechanical fixation behavior of coatings is crucial for a better comprehension of the bonding systems, especially at the interface between the mortar and the substrate. Physical adherence is related, among other things, to the contents of the materials used in the roughcast and mortar coatings, due to the colloidal water penetration into the pores of the substrate. This work evaluated the influence of different lime solution additions replacing the kneading water in the preparation of roughcast and mortar coatings. Two types of substrates were investigated:ceramic bricks and concrete blocks. Three wall masonry panels were constructed, with dimensions of 220 × 180 cm2, one of concrete block and two of ceramic bricks, followed by the application of roughcast and mortar coating with an average thickness of 5 mm and 20 mm, respectively. Direct tensile bond strength tests were performed and the results, with a 95% confidence level, showed that substrate ceramic and treatment in the roughcast exhibited a better behavior regarding the distribution of the tensile bond strength of the tested specimens. However, no significant differences of the amount of addition used (0%, 5%, 10% and 15%) on the tensile bond strength were observed.


Author(s):  
Oleksandr Ahafonov ◽  
◽  
Daria Chepiga ◽  
Anton Polozhiy ◽  
Iryna Bessarab ◽  
...  

Purpose. Substantiation of expediency and admissibility of use of the simplified calculation models of a coal seam roof for an estimation of its stability under the action of external loadings. Methods. To achieve this purpose, the studies have been performed using the basic principles of the theory of elasticity and bending of plates, in which the coal seam roof is represented as a model of a rectangular plate or a beam with a symmetrical cross-section with different support conditions. Results. To substantiate and select methods for studying the bending deformations of the roof in the coal massif containing the maingates, the three-dimensional base plate model and the beam model are compared, taking into account the kinematic boundary conditions and the influence of external distributed load. Using the theory of plate bending, the equations for determining the deflections of the coal seam roof in three-dimensional basic models under certain assumptions have a large dimension. After the conditional division of the plate into beams of unit width and symmetrical section, when describing the normal deflections of the middle surface of the studied models, the transition from the partial derivative equation to the usual differential equations is carried out. In this case, the studies of bending deformations of roof rocks are reduced to solving a flat problem in the cross-section of the beam. A comparison of solutions obtained by the methods of the three-dimensional theory of elasticity and strength of materials was performed. For a beam with a symmetrical section, the deflection lies in a plane whose angle of inclination coincides with the direction of the applied load. The calculations did not take into account the difference between the intensity of the surface load applied to the beam. Differences in determining the magnitude of the deflections of the roof in the model of the plate concerning the model of the beam reach 5%, which is acceptable for mining problems. Scientific novelty. To study the bending deformations and determine the magnitude of the roof deflection in models under external uniform distributed load, placed within the simulated plate, a strip of unit width was selected, which has a symmetrical cross-section and is a characteristic component of the plate structure and it is considered as a separate load-bearing element with supports, the cross-sections of this element is remained flat when bending. The deflection of such a linear element is described by the differential equations of the bent axis of the beam without taking into account the integral stiffness of the model, and the vector of its complete displacement coincides with the vector of the force line. Practical significance. In the laboratory, to study the bending deformations and their impact on the stability of the coal seam roof under external loads, it is advisable to use a model of a single width beam with a symmetrical section with supports, the type of which is determined by rock pressure control and secondary support of the maingate at the extraction layout of the coal mine.


2021 ◽  
Vol 881 ◽  
pp. 149-156
Author(s):  
Mochamad Teguh ◽  
Novi Rahmayanti ◽  
Zakki Rizal

Building material innovations in various interlocking concrete block masonry from local materials to withstand lateral earthquake forces is an exciting issue in masonry wall research. The block hook has an advantage in the interlocking system's invention to withstand loads in the in-plane and out-of-plane orientations commonly required by the masonry walls against earthquake forces. Reviews of the investigation of in-plane and out-of-plane masonry walls have rarely been found in previous studies. In this paper, the results of a series of experimental tests with different interlocking models in resisting the simultaneous in-plane shear and out-of-plane bending actions on concrete blocks are presented. This paper presents a research investigation of various interlocking concrete blocks' mechanical properties with different hook thicknesses. Discussion of the trends mentioned above and their implications towards interlocking concrete block mechanical properties is provided.


2015 ◽  
Vol 111 ◽  
pp. 42-48
Author(s):  
Vladimir I. Andreev ◽  
Nikita Y. Tsybin

Sign in / Sign up

Export Citation Format

Share Document