Development of an index assignment procedure compatible with the regional seismicity in the province of Quebec for the rapid visual screening of existing buildings

2008 ◽  
Vol 35 (9) ◽  
pp. 925-937 ◽  
Author(s):  
Amin Karbassi ◽  
Marie-José Nollet

In the context of the seismic vulnerability evaluation of buildings, the score assignment method can be used as the first step of a multiphase procedure aimed at identifying hazardous buildings that must then be analysed in greater detail. Because the existing Canadian rapid visual screening procedure has not been updated since 1992, a new procedure is proposed based on a set of vulnerability indices for different cities in the province of Quebec. A seismicity level (low, moderate, or high) is attributed to each city using the spectral acceleration response values included in the 2005 edition of National building code of Canada (NBCC) and the criteria proposed in FEMA 310 Handbook for the seismic evaluation of buildings - a prestandard. The structural vulnerability indices (SVIs) are calculated using the recently improved nonlinear static analysis procedure in FEMA 440, Improvement of nonlinear static seismic analysis procedures for each seismicity level. The NBCC 2005 reference soil class C is considered in the calculation of the SVIs, and index modifiers for the building height, irregularities, and design and construction year. The application of these indices to the estimation of the probable damage distribution in building inventories is discussed at the end.

2017 ◽  
Vol 4 ◽  
pp. 24-30
Author(s):  
Shyam Sundar Basukala ◽  
Prem Nath Maskey

Historic buildings of Nepal are mainly constructed from masonry structure. Since masonry structures are weak in tension which leads to the failure of structure. So, to avoid possible damage in environment lives and property it is urgent to conduct vulnerability assessments. Seismic vulnerability of historic masonry buildings constructed in Bhaktapur at Byasi area is carried out for the case study. Five load bearing masonry buildings were selected out of 147 buildings considering opening percentage, storey and type of floor for modeling in SAP 2000 V10 Various methods of rapid visual screening (FEMA 154, EMS 98) are used to determine the vulnerability of the selected building. The Selected Building response is carried out by linear time history analysis. The seismic vulnerability of masonry structures is determined in terms of fragility curves which represent the probability of failure or damage due to various levels of strong ground motions for different damage state slight, moderate, extensive and collapse. From the result of Rapid Visual Screening (RVS) and Fragility curves of the buildings it is found that whole, buildings are found vulnerable from future earthquake.


Author(s):  
Md. Shaharier Alam ◽  
Shamim Mahabubul Haque

Purpose Seismic vulnerability evaluation of various public structures, especially school buildings, is very crucial for designing hazard mitigation initiatives in seismic prone areas. The city of Mymensingh is at great risk of earthquake because of its geographical location, geological structure and proximity to active faults. The city is famous for its ancient and renowned educational institutes that need to be evaluated for understanding the seismic performance of the building during an earthquake. This study aims to evaluate the seismic vulnerability of educational buildings of Mymensingh city using rapid visual screening (RVS) and index based approach. Design/methodology/approach RVS procedure includes field survey and secondary source assessment for evaluating structural vulnerability attributes. Analytical hierarchy process is applied to develop an index focusing on systematic attributes of vulnerability based on expert opinions. Then, a composite vulnerability map is developed combining both structural and systematic vulnerability score providing an equal weight. Findings This study evaluates the seismic vulnerability of 458 educational buildings of Mymensingh city and the result shows that 23.14% educational building has high, 46.29% has moderate and 26.86% has moderately low and only 3.71% buildings has the low seismic vulnerability. This study expected to be helpful in resource targeting and prioritizing seismic hazard mitigation activities for education buildings of Mymensingh city. Originality/value This study endeavors to present a comprehensive vulnerability assessment method by integrating RVS and index based approach that incorporates both structural and systematic dimensions of vulnerability. The result is expected to be helpful in the formulation of disaster prevention policy for vulnerable educational buildings and development of the earthquake-resistant building codes for the new building construction in Mymensingh city.


Author(s):  
Moe Myat Myat Aung ◽  
Mya Nan Aye

Mandalay, the second largest city in Myanmar, is situated near the Sagaing Fault (the major fault in Myanmar) and so it’s a seismic prone area. In Mandalay region, the number of low-rise buildings is much more than that of high-rise buildings. And hence, the seismic safety assessment of low-rise building takes an important role to survive and develop Mandalay as smart city. Detailed seismic evaluation can determine the seismic performance level of the buildings and can give strategies to technically retrofit the structures. First of all, rapid visual screening and preliminary evaluation must be carried out to identify the buildings which need the detailed assessment. Thus, in this study, the rapid visual screening (RVS) and preliminary evaluation will be executed for 26 number of three to eight story RC buildings are investigated for the requirements of detailed assessment with three different RVS and preliminary evaluation methods. The methods used are FEMA P-154, Indian standards and Bangladesh methods. According to the investigation, the results given by FEMA P-154 level 1 and level 2 are more vulnerable than that of other methods. Seismic elevation using seismic index method by Bangladesh can give a reliable data for detail seismic evaluation and retrofit method.     


Author(s):  
S.J.C. Clemente ◽  
J.S.B. Arreza ◽  
M.A.M. Cortez ◽  
J.R.C. Imperial ◽  
M.J.F. Malabanan

2021 ◽  
Vol 24 (1) ◽  
pp. 52-75
Author(s):  
Haider Ali Abass ◽  
Husain Khalaf Jarallah

In this study, previous researches were reviewed in relation to the seismic evaluation and retrofitting of an existing building. In recent years, a considerable number of researches has been undertaken to determine the performance of buildings during the seismic events. Performance based seismic design is a modern approach to earthquake resistant design of reinforcement concrete buildings. Performance based design of building structures requires rigorous non-linear static analysis. In general, nonlinear static analysis or pushover analysis was conducted as an efficient instrument for performance-based design. Pushover analysis came into practice after 1970 year.  During the seismic event, a nonlinear static analysis or pushover analysis is used to analyze building under gravity loads and monotonically increasing lateral forces. These building were evaluated until a target displacement reached. Pushover analysis provides a better understanding of buildings seismic performance, also it traces the progression of damage and failure of structural components of buildings. 


Structures ◽  
2015 ◽  
Vol 3 ◽  
pp. 57-70 ◽  
Author(s):  
Daniele Perrone ◽  
Maria Antonietta Aiello ◽  
Marisa Pecce ◽  
Fernando Rossi