Site fidelity of slimy sculpin (Cottus cognatus): insights from stable carbon and nitrogen analysis

2004 ◽  
Vol 61 (9) ◽  
pp. 1717-1722 ◽  
Author(s):  
M A Gray ◽  
R A Cunjak ◽  
K R Munkittrick

Concerns regarding sentinel species for assessing environmental impacts include residency, abundance, and suitability for measuring responses, if effects are to be attributable to local conditions. Stable isotope analysis was used as a tool to investigate site fidelity of slimy sculpin (Cottus cognatus) to establish residency and exposure for the sculpin. We predicted that sculpin collected from sites adjacent to agricultural activity would show higher δ15N values than those collected from sites in forested areas because of isotopic enrichment by fertilizers in the former. The predominant use of chemical fertilizer applications in the region, however, resulted in no specific enrichment of 15N in sculpin collected in the agricultural region. However, there was an incremental enrichment in the fish muscle tissue of approximately 5‰ in δ13C values in a downstream direction, irrespective of surrounding land use. As a result, the dual-isotope comparison was successful at demonstrating site-specific isotopic signatures across sites for 30 km of the river system. The site-specific signatures suggest that slimy sculpin are not moving considerable distances among sites and are incorporating their isotopic signatures over a narrow spatial scale. The results support the use of the slimy sculpin as a sentinel species for investigating site-specific environmental impacts.

Author(s):  
Francesco Mancini ◽  
Raffaele De Giorgi ◽  
Alessandro Ludovisi ◽  
Salvatrice Vizzini ◽  
Giorgio Mancinelli

AbstractThe introduction of the amphipod Dikerogammarus villosus in European fresh waters is to date recognized as a threat to the integrity of invaded communities. Predation by D. villosus on native benthic invertebrates is assumed as the key determinant of its ecological impact, yet available information describe the species as a primary consumer as well as a carnivore depending on local conditions. Here, we assessed the trophic position (TP) of D. villosus in Lake Trasimeno, a recently invaded lentic system in central Italy, using the CN isotopic signatures of individuals captured in winter spanning two orders of magnitude in body size. TP estimations were compared with those characterizing the native amphipod Echinogammarus veneris and other representative invertebrate predators. On average, D. villosus showed a trophic position higher than E. veneris, and comparable with that of odonate nymphs. An in-depth analysis revealed that large-sized individuals had a trophic position of 3.07, higher than odonates and close to that of the hirudinean predator Erpobdella octoculata, while small-sized specimens had a trophic position of 2.57, similar to that of E. veneris (2.41). These findings indicate that size-related ontogenetic shifts in dietary habits may per se vary the nature of the interaction between Dikerogammarus villosus and native invertebrates from competition to predation. Information collated from published isotopic studies corroborated the generality of our results. We conclude that intra-specific trophic flexibility may potentially amplify and make more multifaceted the impact of the species on other invertebrate species in invaded food webs.


Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1415
Author(s):  
Václav Voltr ◽  
Martin Hruška ◽  
Luboš Nobilis

This paper provides values of economic, energy and environmental assessments of 20 crops and assesses the relationships of soil-climatic conditions in the example of the Czech Republic. The comparison of main soil quality indicators according to the configuration of land and climate regions is performed on the basis of energy and economic efficiency as well as a comparison of the level of environmental impacts. The environmental impacts are identified based on the assessment of emissions from production and also in the form of soil compaction as an indicator of the relationship to soil quality. As concerns soil properties, of major importance is soil skeleton, slope of land and the depth of soil, which cause an increase in emissions from the energy produced. Substantially better emission parameters per 1 MJ through energy crops, the cultivation of perennial crops and silage maize has been supported. Among energy crops, a positive relationship with the quality of soil is seen in alfalfa, with a significant reduction in soil penetrometric resistance; energy crops are also politically justifiable in competition with other crops intended for nutrition of population. The main advantage of energy crops for the low-carbon economy is their CO2 production to MJ, which is almost half, especially in marginal areas with lower soil depths, slopes and stoniness, which can be included in the new agricultural policy.


2021 ◽  
Author(s):  
András Polgár ◽  
Karolina Horváth ◽  
Imre Mészáros ◽  
Adrienn Horváth ◽  
András Bidló ◽  
...  

<p>Crop production is applied on about half of Hungary’s land area, which amounts to approximately 4.5 million hectares. The agricultural activity has significant environmental impacts.</p><p>Our work aims the time series investigation of the impacts of large-scale agricultural cultivation<strong> </strong>on environment and primarily on climate change in<strong> </strong>the test area by applying environmental life cycle assessment (LCA) method.</p><p>The investigated area of Lajta Project can be found in the triangle formed by the settlements Mosonszolnok, Jánossomorja and Várbalog, in the north-western corner of Hungary, in Győr-Moson-Sopron county. The area has intense agri-environment characteristics, almost entirely lacking of grasslands and meadows.</p><p>We were looking for the answer to the question “To what extent does agricultural activity on this area impact the environment and how can it contribute to climate change during a given period?” The selection of the plants included in the analysis was justified by their significant growing area. We analysed the cultivation data of 5 crops: canola, winter barley, winter wheat, green maize and maize. Material flows of arable crop production technologies were defined in time series by the agricultural parcel register data. These covered the size of the area actually cultivated, the operational processes, records on seeds, fertilizer and pesticide use and harvest data by parcels. The examined environmental inventory database contained also the fuel consumption and lubricating oil usage of machine operations, and the water usage of chemical utilization.</p><p>In the life cycle modelling of cultivation, we examined 13 years of maize, 20 years of green maize, 20 years of winter barley, 18 years of winter wheat and 15 years of canola data calculated on 1 ha unit using GaBi life cycle analysis software.</p><p>In addition, we also calculated by an average cultivation model for all cultivated plants with reference data to 1 ha and 1 year period.</p><p>We applied methods and models in our life cycle impact assessment. According to the values of the impact categories, we set up the following increasing environmental ranking of plant cultivation: (1) canola has minimum environmental impacts followed by (2) green maize and (3) maize with slightly higher values, (4) winter barley has 6 times higher values preceded by (5) winter wheat with a slight difference. The previous environmental ranking of the specific cultivated plants’ contribution was also confirmed as regards the overall environmental impact: canola (1.0%) – green maize (4.9%) – maize (7.1%) – winter barley (43.1%) – winter wheat (44.0%).</p><p>Environmental impact category indicator results cumulated to total cultivation periods and total crop growing areas (quantitative approach) display the specific environmental footprints by crops. Increasing environmental ranking of environmental impacts resulted from cultivating the sample area is the following: (1) canola – (2) maize – (3) green maize – (4) winter barley – (5) winter wheat. The slight difference resulted in the rankings in quantitative approach according to the rankings of territorial approach on the investigated area is due to the diversity of cultivation time factor and the crop-growing parameter of the specific crops.</p><p>Acknowledgement: Our research was supported by the „Lajta-Project”.</p>


Author(s):  
J. M. Burns ◽  
D. C. Burns ◽  
J. S. Burns

Section 316(b) of the Clean Water Act regulates the potential environmental impacts of cooling water intakes in order to mitigate the adverse entrainment and impingement effects on aquatic organisms. The recently proposed EPA regulations require that power plants currently using once-through cooling systems at the very minimum, evaluate the cost and environmental benefits of retrofitting to wet or dry cooling towers for their next permit application. However, a sound cooling tower retrofit assessment cannot be confined to cooling tower issues alone. Cooling tower backfits significantly affect the entire cooling system and generating capacity. Though the industry still awaits the EPA’s February 2004 final action ruling to clarify the regulations for existing plants, it is clear that acceptable methods of plant compliance with 316(b) regulations will be decided based upon the costs of new technology available, including cooling tower retrofits. A plant not able to meet the tight impingement and entrainment reduction percentages required under 316(b) will be required to consider the cost of retrofitting technologies versus the expected environmental benefit. The EPA has complied standard costs for retrofitting cooling towers that are extremely optimistic and limited in their scope, and thus tend to be far lower than a plant would actually accrue during a retrofit. These EPA costs of compliance are accepted by default in the cost-benefit analysis unless a plant can make a compelling case that their site-specific costs are much higher than EPA’s estimate or are wholly disproportionate to the environmental benefits accrued by such a retrofit. In either case, an overly simplistic and non-comprehensive tower retrofit cost estimate will increase the chances of a plant being required to implement a closed-cooling system retrofit, which in nearly all cases is the most costly and difficult alternative. In addition to constructing a tower, a cooling tower retrofit also alters many parts of the existing cooling system. Typically, a once-through condenser is designed to operate in a siphon circuit using low pressure buried piping under the turbine building. The condenser, along with its piping, would likely have to be modified to be compatible for a conversion to a higher pressure closed-loop system. The retrofit would require installation of new circulating water pumps to provide the additional required head. Portions of the plant’s large diameter circulating water piping systems and intakes must be decommissioned or redesigned to accommodate the retrofit. The critical parts of any retrofit evaluation will be to identify the site-specific modifications required for a conversion with a reasonably accurate estimate of capital costs. An accurate retrofit evaluation must reflect the impacts on all of the circulating water system components along with the adjusted overall performance. Obtaining accurate cost data on the full scope of a retrofit project is difficult due to many factors. There have been only a handful of cooling tower retrofits in the U.S. The experiences from these are mostly inapplicable due to either their small size or unique factors that facilitated the cooling system conversion. The site-specific nature of each retrofit, including the interpretation of a matrix of environmental siting issues, makes cooling system retrofit estimates very complex. Developing an accurate estimate requires a thorough review the existing cooling system design equipment, features & layout. These data are best obtained from a site visit and interviews with key system and operations personnel. Retrofit budgets for this evaluation should not be based on very “generic” cases prepared without regard to site-specific design & operating limitations. Instead, a realistic turnkey retrofit budget is based on a well planned project that confronts the broad scope of a retrofit including the range of site-specific factors. This paper will summarize the art of the retrofit and provide considerations to develop more reliable and meaningful closedcycle retrofit cooling system cost estimates. It will describe the critical characteristics of cooling towers, pumps, circulating water piping, and condenser modifications. It will provide recommendations to produce reasonably accurate evaluations of the seasonal and peak period (energy penalty) effects of the retrofitted cooling system on plant generation. In fact, those conversion costs and the negative effects on plant generation are the key to determining the realistic effects of a proposed retrofit. Finally, it will present the major consequences of trading-off the adverse aquatic environmental impacts with airborne ones from a retrofitted wet cooling tower.


2005 ◽  
Vol 24 (9) ◽  
pp. 2291 ◽  
Author(s):  
Michelle A. Gray ◽  
R. Allen Curry ◽  
Kelly R. Munkittrick

Ibis ◽  
2013 ◽  
Vol 156 (1) ◽  
pp. 165-175 ◽  
Author(s):  
Anne Charmantier ◽  
Jacques Blondel ◽  
Philippe Perret ◽  
Mireille Harmelin-Vivien

Copeia ◽  
1976 ◽  
Vol 1976 (4) ◽  
pp. 802 ◽  
Author(s):  
Jeffrey W. Foltz

Sign in / Sign up

Export Citation Format

Share Document