Carbon dot doped silica nanoparticles as fluorescent probe for determination of bromate in drinking water samples

2018 ◽  
Vol 96 (1) ◽  
pp. 24-29 ◽  
Author(s):  
Guoqiang Xiang ◽  
Huanhuan Fan ◽  
Heng Zhang ◽  
Lijun He ◽  
Xiuming Jiang ◽  
...  

A simple and effective strategy for designing a fluorescent probe for bromate was described in this work. Organosilane modified carbon dots were prepared by pyrolysis of citric acid in N-(β-aminoethyl)-γ-aminopropyl methyldimethoxysilane solvent at 230 °C and further doped onto silica nanoparticles by a silylation reaction. The fluorescence of carbon dot doped silica nanoparticles was quenched by bromate in acidic medium. By utilizing this property, the nanoparticle could be used as a sensor to detect bromate. The parameters affecting the performance of the sensor probe such as types of acid medium, acid concentration, reaction temperature, and time were investigated and optimized. The detection limit of the sensor was found to be 1.1 ng mL−1, with a linear range from 8 to 400 ng mL−1 and relative standard deviation of 2.0% (150 ng mL−1, n = 9). The method was successfully applied to the determination of bromate in drinking water samples, and the recoveries were in the range of 96.3%–103.7%.

2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
Mohsen Shahlaei ◽  
Alireza Pourhossein

A simple, fast, and sensitive method for determination of total arsenic in drinking water sample by ETAAS after solid phase preconcentration has been developed. The dead biomass ofA. nigerloaded on activated charcoal has been applied as bioadsorbent for preconcentration step. The effects of parameters such as pH, type and concentration of eluent, biosorption time, sample volume, and effect of interfering ions have also been studied. Under the optimum condition, the enrichment factor of 10 for the analyte has been obtained. The accuracy of the method has been investigated by the recovery of spiked standards and the recovery percents between 99 and 102% have been achieved. Total amount of arsenic was determined by reducing As (V) to As (III) with potassium iodide (KI) and ascorbic acid in HCl solution. Under the optimum conditions, for 400 mL of drinking water samples, the detection limit (3σ) and linear range were achieved 1 ng/mL and 5–100 ng/mL, respectively. The relative standard deviation for ten determinations of a spiked sample with concentration of 10 ng/mL As was 3.2%.


2007 ◽  
Vol 42 (8) ◽  
pp. 1392-1396
Author(s):  
R. Idoeta ◽  
M. Herranz ◽  
A. Abelairas ◽  
F. Legarda

2020 ◽  
Vol 5 (1) ◽  
pp. 88
Author(s):  
Sri Royani ◽  
Adita Silvia Fitriana

<p><em>Refill drinking water production is now rapidly increasing in several regions in Indonesia, including Purwokerto. According to the Regulation of Health Minister of the Republic of Indonesia (Permenkes) Number 492/Menkes/Per/IV/2010, heavy metal is one of the parameters of drinking water quality which has adverse impacts on human health. In this study, Arsenic (As) and Cadmium (Cd) would be studied. Atomic Absorption Spectrometry (AAS) Method was used to find As and Cd concentration in refill drinking water samples. The results showed that only one sample containing As from five samples was collected, but there is being safe for drinking according to Regulation of Health Minister of the Republic of Indonesia (Permenkes) Number 492/Menkes/Per/IV/2010. Meanwhile, Cd was not detected in samples. It can be concluded that refill drinking water samples that were taken from several depots in Purwokerto City are being safe for drinking.</em></p>


Sign in / Sign up

Export Citation Format

Share Document