The Stability of Front‐Tracking Scheme for Two Spatial Dimensional Miscible Two Phase Flow

2007 ◽  
Vol 45 (3) ◽  
pp. 1045-1063
Author(s):  
Kou‐Kung Alex Chang
2003 ◽  
Vol 3 ◽  
pp. 266-270
Author(s):  
B.H. Khudjuyerov ◽  
I.A. Chuliev

The problem of the stability of a two-phase flow is considered. The solution of the stability equations is performed by the spectral method using polynomials of Chebyshev. A decrease in the stability region gas flow with the addition of particles of the solid phase. The analysis influence on the stability characteristic of Stokes and Archimedes forces.


Sensors ◽  
2020 ◽  
Vol 20 (7) ◽  
pp. 2088
Author(s):  
Wael Ahmed ◽  
Adib Fatayerji ◽  
Ahmed Elsaftawy ◽  
Marwan Hassan ◽  
David Weaver ◽  
...  

Evaluating the two-phase flow parameters across tube bundles is crucial to the analysis of vibration excitation mechanisms. These parameters include the temporal and local variation of void fraction and phase redistribution. Understanding these two-phase parameters is essential to evaluating the stability threshold of tube bundle configurations. In this work, capacitance sensor probes were designed using finite element analysis to ensure high sensor sensitivity and optimum response. A simulation-based approach was used to calibrate and increase the accuracy of the void fraction measurement. The simulation results were used to scale the normalized capacitance and minimize the sensor uncertainty to ±5%. The sensor and required conditioning circuits were fabricated and tested for measuring the instantaneous void fraction in a horizontal triangular tube bundle array under both static and dynamic two-phase flow conditions. The static calibration of the sensor was able to reduce the uncertainty to ±3% while the sensor conditioning circuit was able to capture instantaneous void fraction signals with frequencies up to 2.5 kHz.


Author(s):  
Omar Sadek ◽  
Atef Mohany ◽  
Marwan A. Hassan

Abstract For decades, fluidelastic instability (FEI) has been known to cause dramatic mechanical failures in tube bundles. Therefore, it has been extensively studied to mitigate its catastrophic consequences. Most of these studies were conducted in controlled experiments where significant simplifications to the geometry and flow conditions were utilized. One of these simplifications is the assumption that all tubes have the same dynamic characteristics. However, in steam generators with U-bend tube configuration, the natural frequencies of tubes are nonuniform due to manufacturing tolerances and tubes' curvature in the U-bend region. Thus, this investigation aims to understand the rule of frequency variation (detuning) on FEI in two-phase flow. This includes investigating the effect of detuning on transverse and streamwise FEI for air-water mixture flow. The role of FEI damping and stiffness couplings was investigated over the entire range of air void fraction, or equivalently, the mass-damping parameter. It was found that frequency detuning could elevate the stability threshold caused by either coupling at high air void fraction in the case of transverse FEI. Furthermore, the frequency detuning had a marginal effect on the stability threshold for water flow. It was observed that the mass-damping parameter has a critical impact on FEI under detuning conditions.


2012 ◽  
Vol 21 (12) ◽  
pp. 124703 ◽  
Author(s):  
Hai-Qiong Xie ◽  
Zhong Zeng ◽  
Liang-Qi Zhang ◽  
Gong-You Liang ◽  
Hiroshi Mizuseki ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document