Gold-Plated Carbon Paste Electrodes for Anodic Stripping Determination of Arsenic

2000 ◽  
Vol 65 (6) ◽  
pp. 1035-1046 ◽  
Author(s):  
Petr Chadim ◽  
Ivan Švancara ◽  
Boris Pihlar ◽  
Karel Vytřas

The applications of gold-plated carbon paste electrodes in anodic stripping voltammetry have been studied in an effort to develop a simple and effective method for the determination of arsenic in water samples. The investigations performed included the choice of supporting electrolyte composition, the optimisation of important experimental parameters, search for appropriate procedure to reduce As(V) to As(III), and some tests of practical applicability of the method, including interference studies. Under optimised conditions, the signal of As was linear within 5-50 μg l-1 with a detection limit of about 1 μg l-1 As (deposition time 10 min). Common elements or ions did not interfere except for Cu(II). The analytical performance of the method has been tested in recovery measurements with model solutions.

2017 ◽  
Vol 13 (1) ◽  
pp. 1
Author(s):  
Irdhawati Irdhawati ◽  
Hery Suyanto ◽  
Putu Yani Andani

<p>In this research, the unmodified and modified carbon paste electrode with zeolite has been prepared, for determination of Cu(II) using anodic stripping voltammetry method. The parameters observed involved deposition time, scan rates, zeolite composition in carbon paste, and validation of working electrode. The optimum performance of carbon paste electrode modified with zeolite was applied for determination of Cu(II) in wastewater of the gong fabrication. The results of this research showed the optimum of deposition time and scan rates obtained at 410 s and 7.5 mV/s for unmodified carbon paste electrode, respectively. The optimum composition of zeolite-modifier is 20% from total graphite, with deposition time 380 s and scan rates 10 mV/s. The detection limit of the measurement of Cu(II) standard solution using unmodified carbon paste electrode is 46.13 ppb, is lower than unmodified carbon paste electrode, 99.93 ppb. Zeolite-modified carbon paste electrode has good precision and accuration. The concentration of Cu(II) in waste water of gong fabrication , using carbon paste electrode modified with zeolite is 93.54 ± 0.87 ppb.</p>


2017 ◽  
Vol 13 (1) ◽  
pp. 1
Author(s):  
Irdhawati Irdhawati ◽  
Hery Suyanto ◽  
Putu Yani Andani

<p>In this research, the unmodified and modified carbon paste electrode with zeolite has been prepared, for determination of Cu(II) using anodic stripping voltammetry method. The parameters observed involved deposition time, scan rates, zeolite composition in carbon paste, and validation of working electrode. The optimum performance of carbon paste electrode modified with zeolite was applied for determination of Cu(II) in wastewater of the gong fabrication. The results of this research showed the optimum of deposition time and scan rates obtained at 410 s and 7.5 mV/s for unmodified carbon paste electrode, respectively. The optimum composition of zeolite-modifier is 20% from total graphite, with deposition time 380 s and scan rates 10 mV/s. The detection limit of the measurement of Cu(II) standard solution using unmodified carbon paste electrode is 46.13 ppb, is lower than unmodified carbon paste electrode, 99.93 ppb. Zeolite-modified carbon paste electrode has good precision and accuration. The concentration of Cu(II) in waste water of gong fabrication , using carbon paste electrode modified with zeolite is 93.54 ± 0.87 ppb.</p>


Sign in / Sign up

Export Citation Format

Share Document