The Polarographic and Voltammetric Determination of 1(4'-Carbamoylphenyl)-3,3-dimethyltriazene

1992 ◽  
Vol 57 (6) ◽  
pp. 1230-1236
Author(s):  
Jiří Barek ◽  
Viktor Mejstřík ◽  
Saafa Toubar ◽  
Jiří Zima

A study was made of the polarographic behaviour of 1-(4'-carbamoylphenyl)-3,3-dimethyltriazene and optimum conditions were found for its determination by tast polarography and differential pulse polarography at a static mercury drop electrode and by fast scan differential pulse voltammetry at a hanging mercury drop electrode in the concentration range 1 . 10-4 to 2 . 10-7 mol l-1. A further increase in the sensitivity can be achieved through adsorptive accumulation of the test substance on the surface of a hanging mercury drop, permitting the determination to be extended to the concentration range 1 . 10-7 - 2 . 10-9 mol l-1.

1991 ◽  
Vol 56 (10) ◽  
pp. 2073-2081 ◽  
Author(s):  
Jiří Barek ◽  
Safa Toubar ◽  
Jiří Zima

A study was carried out of the polarographic behaviour of the genotoxic substance 1-(2’-carbamoylphenyl)-3,3-dimethyltriazene and optimum conditions were found for its determination by tast polarography or differential pulse polarography at a static mercury drop electrode and by fast scan differential pulse voltammetry at a hanging mercury drop electrode in the concentration range 1 . 10-4 -2 . 10-7 mol 1-1. The sensivity of the determination can be further improved through adsorptive accumulation of the test substance on the surface of the hanging mercury drop electrode; five-minute accumulation in unstirred solution permits determination in the concentration range (2-10 . 10-8 mol 1-1 and two-minute accumulation in stirred solution allows determination in the range (2-10) . 10-9 mol 1-1.


1993 ◽  
Vol 58 (9) ◽  
pp. 2021-2038 ◽  
Author(s):  
Jiří Barek ◽  
Dana Dřevínková ◽  
Jiří Zima

The polarographic behaviour of 1-(2'-nitrophenyl)-3,3-dimethyltriazene in mixed aqueous-methanolic solvent was investigated by tast polarography, differential pulse polarography, and fast scan differential pulse voltammetry at a hanging mercury drop electrode. A mechanism is suggested for the reduction of the compound investigated. The optimum conditions were found for the determination of this analyte by tast polarography over the concentration region of 100 to 2 μmol l-1 and by differential pulse polarography or fast scan differential pulse voltammetry at a hanging mercury drop electrode over the region of 100 to 0.2 μmol l-1. Additional sensitivity increase in the last-mentioned technique was achieved by adsorptive accumulation of analyte on the hanging mercury drop surface, owing to which the concentration region was depressed to 0.1 - 0.02 μmol l-1.


1992 ◽  
Vol 57 (11) ◽  
pp. 2263-2271
Author(s):  
Jiří Barek ◽  
Jana Kubíčková ◽  
Viktor Mejstřík ◽  
Jiří Zima

A study was made of the polarographic reduction of the title triazene, a mechanism was proposed for this process and optimal conditions were found for its analytical application using tast polarography in the range 1 . 10-4 - 2 . 10-6 mol l-1, differential pulse polarography in the range 1 . 10-4 - 2 . 10-7 mol l-1 and fast scan differential pulse voltammetry at a hanging mercury drop electrode in the range 1 . 10-4 - 2 . 10-7 mol l-1. The sensitivity of the latter technique was increased through adsorptive accumulation of the test substance on the surface of the working electrode, permitting determination in the concentration range 1 . 10-7 - 2 . 10-9 mol l-1.


1993 ◽  
Vol 58 (2) ◽  
pp. 295-309 ◽  
Author(s):  
Jiří Barek ◽  
Dana Dřevínková ◽  
Viktor Mejstřík ◽  
Jiří Zima

The polarographic reduction of N,N-dimethyl-4-amino-3'-nitroazobenzene was studied by tast polarography and differential pulse polarography, constant potential coulometry and cyclic voltammetry and mechanism was proposed for the reduction. Optimal conditions were found for the determination of the test substance using tast polarography in concentration range 1 . 10-4 - 2 . 10-6 mol l-1, differential pulse polarography at classical dropping mercury electrode and fast scan differential pulse voltammetry at a hanging mercury drop electrode in range 1 . 10-4 - 2 . 10-7 mol l-1 and linear scan voltammetry at a hanging mercury drop electrode in range 1 . 10-5 - 2 . 10-8 mol l-1. A further increase in the sensitivity was achieved through adsorptive accumulation of the test substance on the surface of the working electrode, permitting the determination to be carried out in the concentration range 1 . 10-7 - 2 . 10-9 mol l-1.


1988 ◽  
Vol 53 (5) ◽  
pp. 921-928
Author(s):  
Jiří Barek ◽  
Janina Balsiene ◽  
Barbara Tietzová ◽  
Jiří Zima

The reduction of mutagenic bisazodye trypane blue has been studied at a mercury electrode, a mechanism has been proposed and optimal conditions found for its analytical application. The use of a dropping mercury electrode with a renewable surface yielded a detection limit of 8 . 10-7 mol l-1 for TAST polarography, and 8 . 10-8 mol l-1 for differential pulse polarography; the use of a hanging mercury drop electrode with an unrenewed surface during the measurement yielded detection limit of 6 . 10-8 mol l-1 for fast scan differential pulse voltammetry and 4 . 10-8 mol l-1 for linear scan voltammetry. Preliminary adsorptive accumulation of the determined substance on the surface of the hanging mercury drop electrode led to a decrease in the detection limit to 5 . 10-9 mol l-1 for linear scan voltammetry.


1986 ◽  
Vol 51 (11) ◽  
pp. 2466-2472 ◽  
Author(s):  
Jiří Barek ◽  
Antonín Berka ◽  
Ludmila Dempírová ◽  
Jiří Zima

Conditions were found for the determination of 6-mercaptopurine (I) and 6-thioguanine (II) by TAST polarography, differential pulse polarography and fast-scan differential pulse voltammetry at a hanging mercury drop electrode. The detection limits were 10-6, 8 . 10-8, and 6 . 10-8 mol l-1, respectively. A further lowering of the detection limit to 2 . 10-8 mol l-1 was attained by preliminary accumulation of the determined substances at the surface of a hanging mercury drop.


1990 ◽  
Vol 55 (6) ◽  
pp. 1508-1517 ◽  
Author(s):  
Jiří Barek ◽  
Dagmar Civišová ◽  
Ashutosh Ghosh ◽  
Jiří Zima

The polarographic reduction of the title azo dye was studied and optimal conditions were found for its analytical utilization in the concentration range 1 . 10-6 - 1 . 10-7 mol l-1 using differential pulse polarography and 1 . 10-6 - 1 . 10-8 mol l-1 using fast scan differential pulse voltammetry or linear scan voltammetry at a hanging mercury drop electrode. When the latter technique is combined with adsorptive accumulation of the studied substance on the surface of the hanging mercury drop, the determination limit can be further decreased to 3 . 10-9 mol l-1.


1991 ◽  
Vol 56 (3) ◽  
pp. 595-601 ◽  
Author(s):  
Jiří Barek ◽  
Gulamustafa Malik ◽  
Jiří Zima

Optimum conditions were found for the determination of 4-nitrobiphenyl by fast scan differential pulse voltammetry at a hanging mercury drop electrode in the concentration range 1 . 10-5 to 2 . 10-7 mol l-1. A further increase in sensitivity was attained by adsorptive accumulation of this substance on the surface of the working electrode, permitting determination in the concentration range (2 – 10) . 10-8 mol l-1 with one minute accumulation of the substance in unstirred solution or (2 – 10) . 10-9 mol l-1 with three-minute accumulation in stirred solution. Linear scan voltammetry can be used to determine 4-nitrobiphenyl in the concentration range (2 – 10) . 10-9 mol l-1 with five-minute accumulation in stirred solution, with the advantage of a smoother baseline and smaller interference from substances that yield only tensametric peaks.


1997 ◽  
Vol 62 (4) ◽  
pp. 597-608 ◽  
Author(s):  
Jiří Barek ◽  
Pham Tuan Hai ◽  
Viktor Mejstřík ◽  
Josino C. Moreira ◽  
Jiří Zima

The polarographic behaviour of N,N-dimethyl-4-amino-4'-sulfoazobenzene was investigated by tast polarography and differential pulse polarography at a dropping mercury electrode, constant-potential coulometry at a large area mercury electrode and cyclic voltammetry at a hanging mercury drop electrode. Optimum conditions have been found for its determination by tast polarography in the concentration range of 2-100 μmol l-1, differential pulse polarography at a dropping mercury electrode in the concentration range of 0.2-100 μmol l-1 and by differential pulse voltammetry at a hanging mercury drop electrode in the concentration range of 0.02-10 μmol l-1. The sensitivity of the determination can be further improved by adsorptive accumulation of the test substance on the hanging mercury drop electrode. Three-minute accumulation in stirred solution allows determination in the range of 0.2-100 nmol l-1.


1986 ◽  
Vol 51 (10) ◽  
pp. 2083-2090 ◽  
Author(s):  
Jiří Barek ◽  
Roman Hrnčíř

Conditions were found for the determination of chemical carcinogen N,N-dimethyl-4-aminoazobenzene by TAST and differential pulse polarography, fast scan differential pulse voltammetry and linear sweep voltammetry at a hanging mercury drop electrode in a mixed aqueous-methanolic medium. The detection limit of the last two methods, approximately 10-8 mol l-1, can be further lowered by preliminary accumulation of the substance to be determined by adsorption at a working electrode. The applicability of these methods to the analysis of biological materials, directly or combined with an extraction, was demonstrated.


Sign in / Sign up

Export Citation Format

Share Document