The flow rate and the hold-up of solids under the counter-current flow of liquid phase in a vibrating plate column

1983 ◽  
Vol 48 (2) ◽  
pp. 439-448
Author(s):  
Eva Klašková ◽  
Vladimír Rod

Flow rates and mean hold-ups of solids have been measured under the counter-current flow of water in a 50 mm in diameter vibrating perforated plate column. Experimental data have been described by a mathematical model expressing the specific flow rate of solids in dependence on the hold-up, terminal velocity of the particles, porosity of the plate, specific flow rate of the continuous phase and the frequency and amplitude of plate vibrations. It has been found that for systems exhibiting low particle terminal velocity the pumping effect of the plates may increase the flow rate of the dispersed phase to a value corresponding to the flow in the empty column.

1979 ◽  
Vol 34 (9) ◽  
pp. 1141-1149 ◽  
Author(s):  
V. Jiřičný ◽  
M. Krátký ◽  
J. Procházka

Author(s):  
Noritoshi Minami ◽  
Michio Murase ◽  
Akio Tomiyama

In this paper, results of experiments and numerical simulations for counter-current flow in a pressurized water reactor hot leg under reflux cooling are summarized. In the experiments, we used two types of small scale PWR hot legs. One was a 1/5th scale rectangular duct, and the other was a 1/15th scale circular pipe. Air and water were used for gas and liquid phases. The air flow rate and the supplied water flow rate were varied to observe flow pattern and measure the counter-current flow limitation (CCFL) characteristics. Flow patterns in the elbow and the inclined section were strongly affected by those in the horizontal section. In the 1/15th scale circular pipe experiments, CCFL characteristics obtained by increasing the air flow rate differed from those obtained by decreasing it. CCFL characteristics corresponded to the flow pattern transition. In the numerical simulations, we used a three-dimensional two-fluid model to evaluate the capability of predicting counter-current flow in the hot leg. Good agreements between measured and predicted flow patterns and CCFL characteristics were obtained by using an appropriate set of correlations for interfacial friction coefficient. We also carried out simulations of actual hot leg conditions to examine the effects of fluid properties and size. Predicted flow patterns and CCFL characteristics were close to those of scale model calculations. We concluded the combination of calculation model and interfacial friction coefficients used in this study can predict the counter-current flow in a hot leg.


Author(s):  
Christophe Valle´e ◽  
Tobias Seidel ◽  
Dirk Lucas ◽  
Akio Tomiyama ◽  
Michio Murase

In order to investigate the two-phase flow behaviour during counter-current flow limitation in the hot leg of a pressurised water reactor, two test models were built: one at the Kobe University and the other at the TOPFLOW test facility of Forschungszentrum Dresden-Rossendorf (FZD). Both test facilities are devoted to optical measurement techniques, therefore, a flat hot leg test section design was chosen. Counter-current flow limitation (CCFL) experiments were performed, simulating the reflux condenser cooling mode appearing in some accident scenarios. The fluids used were air and water, both at room temperature. The pressure conditions were varied from atmospheric at Kobe to 3.0 bar absolute at TOPFLOW. According to the presented review of the literature, very few data is available on flooding in channels with rectangular cross-section, and no experiments were performed in the past in such rectangular models of a hot leg. Usually, the macroscopic effects of CCFL are represented in a flooding diagram, where the gas flow rate is plotted versus the discharge water flow rate. Commonly, the non-dimensional superficial velocity (also known as the Wallis parameter) is used to plot the flooding diagram. However, the classical definition of the Wallis parameter contains the pipe diameter as characteristic length, which was originally defined by Wallis (1969) for counter-current flow limitation in vertical pipes and not in near horizontal channels with rectangular cross-section. In order to be able to perform comparisons with pipe experiments and to extrapolate to the power plant scale, the appropriate characteristic length should be determined. Because the experimental projects on this subject at the Kobe University and at FZD were launched independently, a detailed comparison of both test facilities is presented. With respect to the CCFL behaviour, it is shown that the essential parts of the two hot leg test sections are very similar. This geometrical analogy allows to perform meaningful comparisons. However, clear differences in the dimensions of the cross-section (H × W = 150 × 10 mm2 in Kobe, 250 × 50 mm2 at FZD) make it possible to point out the right characteristic length for hot leg models with rectangular cross-sections. The hydraulic diameter, the channel height and the Laplace critical wavelength (leading to the Kutateladze number) were tested. The experimental results obtained in the two test facilities clearly show that the channel height is the suited characteristic length. Finally, the experimental results are compared with similar experiments and empirical correlations for pipes available in the literature. In spite of the scatter of the data and of the different correlations, it was noticed that flooding is reached at slightly lower gas fluxes in the hot leg models with rectangular cross-section compared to pipes.


1979 ◽  
Vol 34 (9) ◽  
pp. 1151-1158 ◽  
Author(s):  
V. Jiřičný ◽  
M. Krátký ◽  
J. Procházka

Sign in / Sign up

Export Citation Format

Share Document