Application of semiconductor sensors to gas analysis

1979 ◽  
Vol 44 (9) ◽  
pp. 2598-2602 ◽  
Author(s):  
Jan Michal

A device was set up based on semiconductor sensors, which made it possible to study the conditions of the sensor response to a change of the concentration of combustible gases and vapours in the atmosphere monitored. The conditions were established under which the method can be applied in atmosphere analysis to the determination of the concentration of a combustible gas or vapour.

1996 ◽  
Vol 33 (1) ◽  
pp. 311-323 ◽  
Author(s):  
A. Witteborg ◽  
A. van der Last ◽  
R. Hamming ◽  
I. Hemmers

A method is presented for determining influent readily biodegradable substrate concentration (SS). The method is based on three different respiration rates, which can be measured with a continuous respiration meter which is operated in a cyclic way. Within the respiration meter nitrification is inhibited through the addition of ATU. Simulations were used to develop the respirometry set-up and decide upon the experimental design. The method was tested as part of a large measurement programme executed at a full-scale plant. The proposed respirometry set-up has been shown to be suitable for a semi-on-line determination of an influent SS which is fully based on the IAWQ #1 vision of the activated sludge process. The YH and the KS play a major role in the principle, and should be measured directly from the process.


1989 ◽  
Vol 54 (7) ◽  
pp. 1785-1794 ◽  
Author(s):  
Vlastimil Kubáň ◽  
Josef Komárek ◽  
Zbyněk Zdráhal

A FIA-FAAS apparatus containing a six-channel sorption equipment with five 3 x 26 mm microcolumns packed with Spheron Oxin 1 000, Ostsorb Oxin and Ostsorb DTTA was set up. Combined with sorption from 0.002M acetate buffer at pH 4.2 and desorption with 2M-HCl, copper can be determined at concentrations up to 100, 150 and 200 μg l-1, respectively. For sample and eluent flow rates of 5.0 and 4.0 ml min-1, respectively, and a sample injection time of 5 min, the limit of copper determination is LQ = 0.3 μg l-1, repeatability sr is better than 2% and recovery is R = 100 ± 2%. The enrichment factor is on the order of 102 and is a linear function of time (volume) of sample injection up to 5 min and of the sample injection flow rate up to 11 ml min-1 for Spheron Oxin 1 000 and Ostsorb DTTA. For times of sorption of 60 and 300 s, the sampling frequency is 70 and 35 samples/h, respectively. The parameters of the FIA-FAAS determination (acetylene-air flame) are comparable to or better than those achieved by ETA AAS. The method was applied to the determination of traces of copper in high-purity water.


1996 ◽  
Vol 61 (6) ◽  
pp. 844-855 ◽  
Author(s):  
Olga Šolcová ◽  
Petr Schneider

It was shown that the sampling loop, detector and connecting elements in the chromatographic set-up for determination of transport parameters by the dynamic method significantly influence the response peaks from columns packed with porous or nonporous particles. A method, based on the use of convolution theorem, was developed which can take these effects into account. The applicability of this method was demonstrated on the case of axial dispersion in a single-pellet-string column (SPSR) packed with nonporous particles. It is possible to handle also responses from columns packed with porous particles by a similar procedure.


1980 ◽  
Vol 53 (3) ◽  
pp. 437-511 ◽  
Author(s):  
D. W. Brazier

Abstract An attempt has been made to review the development of thermoanalytical procedures as they have been applied to elastomers and elastomer systems over the past 10 years. For all rubber industry products, temperature and its effects, either alone or in conjunction with the chemical environment, play an important role from the production stage through to the final failure of the product in the field. It is thus not surprising that thermal analysis, in which temperature is the prime variable, has found such diverse applications in elastomer studies. The identification and quantitative analysis of rubber formulations have received most attention. Such formulations produce characteristic “fingerprints” when studied in DTA, DSC, TG, or TMA. In DSC, the determination of the glass transition characteristics, the observation and determination of crystallinity, the detection of cyclization reactions, and the monitoring of thermal and oxidative degradation characteristics can all be observed in a single experiment covering the temperature range from −150 to +600°C. At normal heating rates, e.g., 20°C/min, such information is available in 40 min. TG/DTG analysis can yield the elastomer or elastomers content, oil and plasticizer, carbon black (level and often type), and inorganic ash in less than 60 min. Processing and curing can also be studied. Blend compatibility can be assessed on the basis of both Tg and crystallinity measurements and the data used to determine optimum mixing times. Sulfur vulcanization and peroxide curing of elastomers is readily monitored by DSC and can be used for confirmation analysis of the presence of curatives. Limitations in such analysis exist, but as understanding and ability to interpret cure exotherms increase, valuable information about the mechanism and the nature of the cured network will be obtained. The testing of rubber compounds involves many hours of labor by current procedures. The rapidity of thermal analysis promises to offer some relief. In addition to DSC and TG, TMA, a relatively new technique, offers a rapid approach to low-temperature testing. Dynamic mechanical analysis (DMA) offers a rapid route to determining dynamic properties, but as yet, relatively little has been published on the application of this new technique to elastomers. As environmental concern increases, techniques such as evolved gas analysis (EGA) and combined techniques such as TG/gas chromatography are predicted to play an important role. As for the future, it is readily apparent that the principles of the methods have been established and, in several cases, it now remains to reduce them to a practical level. In some areas, such as vulcanization studies, much remains to be undertaken to improve our interpretive skills. Although there is some indication that certain industries have produced “in-house” standards for the analysis of rubber compounds by DSC and TG/DTG, it will only be when national and international standards organizations study and produce standard procedures, that the techniques will be generally adopted. Maurer's prediction in 1969 of increased applications of DTA and TG in elastomer studies has undoubtedly proved correct, and with the proliferation of reliable commercial instrumentation, significant developments can be anticipated in the next decade.


Sign in / Sign up