Process of magnetic field penetration into the high-temperature superconductor YBa2Cu3O7−δ

2000 ◽  
Vol 42 (8) ◽  
pp. 1398-1402 ◽  
Author(s):  
V. M. Arzhavitin ◽  
N. N. Efimova ◽  
M. B. Ustimenkova ◽  
V. A. Finkel’
1989 ◽  
Vol 156-157 ◽  
pp. 867-870 ◽  
Author(s):  
A. Mansour ◽  
R.O. Hilleke ◽  
G.P. Felcher ◽  
R.B. Laibowitz ◽  
P. Chaudhari ◽  
...  

2020 ◽  
Vol 92 (2) ◽  
pp. 20601
Author(s):  
Abdelaziz Labrag ◽  
Mustapha Bghour ◽  
Ahmed Abou El Hassan ◽  
Habiba El Hamidi ◽  
Ahmed Taoufik ◽  
...  

It is reported in this paper on the thermally assisted flux flow in epitaxial YBa2Cu3O7-δ deposited by Laser ablation method on the SrTiO3 substrate. The resistivity measurements ρ (T, B) of the sample under various values of the magnetic field up to 14T in directions B∥ab-plane and B∥c-axis with a dc weak transport current density were investigated in order to determine the activation energy and then understand the vortex dynamic phenomena and therefore deduce the vortex phase diagram of this material. The apparent activation energy U0 (B) calculated using an Arrhenius relation. The measured results of the resistivity were then adjusted to the modified thermally assisted flux flow model in order to account for the temperature-field dependence of the activation energy U (T, B). The obtained values from the thermally assisted activation energy, exhibit a behavior similar to the one showed with the Arrhenius model, albeit larger than the apparent activation energy with ∼1.5 order on magnitude for both cases of the magnetic field directions. The vortex glass model was also used to obtain the vortex-glass transition temperature from the linear fitting of [d ln ρ/dT ] −1 plots. In the course of this work thanks to the resistivity measurements the upper critical magnetic field Hc2 (T), the irreversibility line Hirr (T) and the crossover field HCrossOver (T) were located. These three parameters allowed us to establish a phase diagram of the studied material where limits of each vortex phase are sketched in order to optimize its applicability as a practical high temperature superconductor used for diverse purposes.


2021 ◽  
Vol 11 (6) ◽  
pp. 2741
Author(s):  
Sergey Zanegin ◽  
Nikolay Ivanov ◽  
Vasily Zubko ◽  
Konstantin Kovalev ◽  
Ivan Shishov ◽  
...  

The article is devoted to the study of losses in devices based on high-temperature superconductors of the 2nd generation. The complexity of the devices under study increases from a single rack coil to a winding assembled from several coils, and finally to an electric machine operating in generator mode. This is the way to experimentally study the behavior of 2nd generation high temperature superconductor (2G HTS) carrying a transport current in various conditions: self-field, external DC, and AC magnetic field. Attention is also paid to the losses in the winding during its operation from the inverter, which simulates the operating conditions in the motor mode of a propulsion system.


1989 ◽  
Vol 39 (4) ◽  
pp. 2748-2751 ◽  
Author(s):  
D. W. Cooke ◽  
R. L. Hutson ◽  
R. S. Kwok ◽  
M. Maez ◽  
H. Rempp ◽  
...  

2009 ◽  
Vol 289-292 ◽  
pp. 303-309
Author(s):  
N.M. Nemes ◽  
C. Visani ◽  
J. Garcia-Barriocanal ◽  
F.Y. Bruno ◽  
Z. Sefrioui ◽  
...  

We report on the interplay between ferromagnetism and superconductivity in trilayers La0.7Ca0.3MnO3/YBa2Cu3O7/La0.7Ca0.3MnO3 made of half metallic manganite and high temperature superconductor cuprate. Samples with a fully oxygenated cuprate show a magnetic field interval where the magnetizations of the manganite are aligned antiparallel. A considerable magnetoresistance accompanies the switching between magnetization configurations (parallel vs. antiparallel) of the manganite moments. Suppression of the free carrier density of the cuprate which occurs upon oxygen depletion, results in deep modifications in the shape of the normal state hysteresis loops indicating that there may be a magnetic coupling mediated by free carrier density of the cuprate. This result outlines the importance of quasiparticle transmission in the interplay between ferromagnetism and superconductivity in this kind of samples.


Author(s):  
Zulkarnay Zakaria ◽  
Mohd Fahajumi Jumaah ◽  
Mohd Saiful Badri Mansor ◽  
Khairi Mat Daud ◽  
Mohd Hafiz Fazalul Rahiman ◽  
...  

Terapi merupakan antara teknik perubatan tertua dalam mengekalkan kesihatan badan terutama daripada aliran darah yang tidak baik, strok dan beberapa penyakit yang lain. Teknik ini termasuklah akupuntur, guasa dan juga urutan. Terdapat juga teknik terapi moden seperti terapi warna, terapi ozon, terapi dadah dan banyak lagi. Kertas kajian ini akan mengetengahkan penjana terapi elektromagnet, satu alat yang mempunyai potensi aplikasi terapi dalam bidang perubatan. Alat ini menghasilkan medan magnet berfrekuensi sederhana sebagai sumber terapi. Perkakasan yang berskala kecil berfrekuensi sederhana dan berkos rendah ini telah dibangunkan dan telah diuji pada tisu biologi bagi mengukur tahap ketembusan medan magnet. Ujian ini telah membuktikan bahawa medan magnet yang telah dihasilkan mampu menembusi tisu lembut bersaiz sehingga 2 cm dengan jarak 7 cm daripada sumber. Kebolehan penembusan sistem ini terhadap tisu lembut memberikan peluang yang cerah kepada kajian ini memandangkan medan magnet telah menunjukkan potensi sebagai sebahagian daripada terapi untuk memulihkan migraine, strok, kekejangan dan beberapa yang lain selain boleh diaplikasikan dalam pengimejan tomografi induksi magnet. Kata kunci: Terapi elektromagnet, medan magnet, penembusan, tisu lembut, aplikasi perubatan Therapy is among the oldest medication technique in maintaining the health of the body especially from bad blood circulation, stroke and several others. This technique includes acupuncture, guasa and also massage. There are also modern therapy techniques like colour therapy, water therapy, ozone therapy, drug therapy and others. This paper will highlight electromagnetic therapy generator, a device which has the potential of therapy application in medical field. This device produce medium frequency magnetic field as a therapy source. This small scale medium frequency and low cost hardware that has been developed was tested on the biological tissue for the purpose of measuring the magnetic field penetration. The testing has proven that the generated magnetic field is able to penetrate the soft tissue up to 2 cm with distance from the source up to 7 cm. The capability of the system penetrations through the soft tissues provide the bright future of this research since magnetic field have shown the potential as being part of the therapy for curing migraine, stroke, cramp and several others besides the application in the magnetic induction tomography imaging. Key words: Electromagnetic therapy, magnetic field, penetration, soft tissue; medical applications


Sign in / Sign up

Export Citation Format

Share Document