Diverse rock types detected in the lunar South Pole–Aitken Basin by the Chang’E-4 lunar mission

Geology ◽  
2020 ◽  
Vol 48 (7) ◽  
pp. 723-727 ◽  
Author(s):  
Jun Huang (黄俊) ◽  
Zhiyong Xiao (肖智勇) ◽  
Long Xiao (肖龙) ◽  
Briony Horgan ◽  
Xiaoyi Hu (胡晓依) ◽  
...  

Abstract The South Pole–Aitken (SPA) basin, located between the South Pole and Aitken crater on the far side of the Moon, is the largest confirmed lunar impact structure. The pre-Nectarian SPA basin is a 2400 × 2050 km elliptical structure centered at 53°S, 191°E, which should have exposed lower crust and upper mantle due to the enormous excavation depth. Olivine, the dominant mineral in Earth’s mantle, has only been identified in small and localized exposures in the margins of the SPA basin, and the dominant mafic component is, instead, pyroxene. These mineralogical characteristics could be explained by the recent hypothesis that the lunar upper mantle is dominated by low-calcium pyroxene, not olivine. Here, we present observations from imaging and spectral data from China’s Chang’E-4 (CE-4) lunar mission in the first 4 synodic days, especially the first in situ visible/near-infrared spectrometer observations of an exposed boulder. We identified a variety of rock types, but not the recently reported olivine-rich materials in the landing region. The results are consistent with orbital observations. The obtained mineralogical information provides a better understanding of the nature and origin of SPA materials.

Micromachines ◽  
2019 ◽  
Vol 10 (2) ◽  
pp. 149 ◽  
Author(s):  
Zifeng Lu ◽  
Jinghang Zhang ◽  
Hua Liu ◽  
Jialin Xu ◽  
Jinhuan Li

In the Hadamard transform (HT) near-infrared (NIR) spectrometer, there are defects that can create a nonuniform distribution of spectral energy, significantly influencing the absorbance of the whole spectrum, generating stray light, and making the signal-to-noise ratio (SNR) of the spectrum inconsistent. To address this issue and improve the performance of the digital micromirror device (DMD) Hadamard transform near-infrared spectrometer, a split waveband scan mode is proposed to mitigate the impact of the stray light, and a new Hadamard mask of variable-width stripes is put forward to improve the SNR of the spectrometer. The results of the simulations and experiments indicate that by the new scan mode and Hadamard mask, the influence of stray light is restrained and reduced. In addition, the SNR of the spectrometer also is increased.


NIR news ◽  
2019 ◽  
Vol 30 (5-6) ◽  
pp. 35-38
Author(s):  
Verena Wiedemair ◽  
Christian Wolfgang Huck

The use of ever smaller near-infrared instruments is becoming more and more prevalent, since they are cheaper, more versatile and often advertised as high-performance spectrometer. The last claim is rarely verified by independent researchers, which is why the presented work evaluates the performance of three hand-held spectrometers in comparison to a benchtop instrument. Seventy-seven samples comprising buckwheat, millet and oat were investigated for their total antioxidant capacity using Folin–Ciocalteu and near-infrared spectroscopy. Partial least squares regression models were established using cross- and test set validation. Results showed that all instruments were able to predict total antioxidant capacity to some extent. The coefficients of determinations ranged from 0.823 to 0.951 for cross-validated and from 0.849 to 0.952 for test set validated models. Errors for cross-validated models ranged from 1.11 to 2.08 mgGAE/g and for test set validated models from 1.02 to 1.86 mgGAE/g.


2021 ◽  
Author(s):  
Russell Farrugia ◽  
Barnaby Portelli ◽  
Ivan Grech ◽  
Joseph Micallef ◽  
Owen Casha ◽  
...  

2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Nima Khavanin ◽  
Halley Darrach ◽  
Franca Kraenzlin ◽  
Pooja S. Yesantharao ◽  
Justin M. Sacks

Sign in / Sign up

Export Citation Format

Share Document