scholarly journals Effects of Ionic Strength on Bacteriophage MS2 Behavior and Their Implications for the Assessment of Virus Retention by Ultrafiltration Membranes

2010 ◽  
Vol 77 (1) ◽  
pp. 229-236 ◽  
Author(s):  
Aurelie Furiga ◽  
Gwenaelle Pierre ◽  
Marie Glories ◽  
Pierre Aimar ◽  
Christine Roques ◽  
...  

ABSTRACTBacteriophage MS2 is widely used as a surrogate to estimate pathogenic virus elimination by membrane filtration processes used in water treatment. Given that this water technology may be conducted with different types of waters, we focused on investigating the effects of ionic strength on MS2 behavior. For this, MS2 was analyzed while suspended in solutions of various ionic strengths, first in a batch experiment and second during membrane ultrafiltration, and quantified using (i) quantitative reverse transcriptase PCR (qRT-PCR), which detects the total number of viral genomes, (ii) qRT-PCR without the RNA extraction step, which reflects only particles with a broken capsid (free RNA), and (iii) the PFU method, which detects only infectious viruses. At the beginning of the batch experiments using solutions containing small amounts of salts, losses of MS2 infectivity (90%) and broken particles (20%) were observed; these proportions did not change during filtration. In contrast, in high-ionic-strength solutions, bacteriophage kept its biological activity under static conditions, but it quickly lost its infectivity during the filtration process. Increasing the ionic strength decreased both the inactivation and the capsid breakup in the feed suspension and increased the loss of infectivity in the filtration retentate, while the numbers of MS2 genomes were identical in both experiments. In conclusion, the effects of ionic strength on MS2 behavior may significantly distort the results of membrane filtration processes, and therefore, the combination of classical and molecular methods used here is useful for an effective validation of the retention efficiency of ultrafiltration membranes.

2010 ◽  
Author(s):  
Aurelie Furiga ◽  
Gwenaelle Pierre ◽  
Marie Glories ◽  
Pierre Aimar ◽  
Christine Roques ◽  
...  

2002 ◽  
Vol 2 (5-6) ◽  
pp. 307-311
Author(s):  
P. Côté ◽  
J. Cadera ◽  
N. Adams ◽  
G. Best

Membrane filtration has become the preferred alternative to conventional technology to remove water-borne pathogens in the preparation of drinking water. This paper presents the integrity monitoring and maintenance options for the ZeeWeed® immersed membrane. Results from two versions of air-based tests, a pressure decay test and a vacuum decay test are presented and shown to be conservative when compared to challenge results from independent studies.


Foods ◽  
2021 ◽  
Vol 10 (8) ◽  
pp. 1804
Author(s):  
Daniel Plante ◽  
Julio Alexander Bran Barrera ◽  
Maude Lord ◽  
Irène Iugovaz ◽  
Neda Nasheri

Foodborne viruses such as norovirus and hepatitis A virus cause frequent outbreaks associated with the consumption of raw or undercooked oysters. Viral particles are bioaccumulated in the oyster’s digestive glands, making RNA extraction and RT-PCR detection difficult due to the complex nature of the food matrix and the presence of RT-PCR inhibitors. Herein, we have developed a viral RNA extraction protocol from raw oysters using murine norovirus (MNV) as a surrogate for human noroviruses. The method combines lysis in Tri-Reagent reagent, followed by RNA extraction using Direct-Zol purification columns and lithium chloride precipitation. Viral load quantification was performed by both qRT-PCR and droplet-digital RT-PCR. We have demonstrated that this method can efficiently remove RT-PCR inhibitors, and is sensitive enough to reliably detect viral contamination at 25 PFU/0.2 g. We have also compared the efficiency of this method with the ISO 15216-1:2017 method and Method E developed by Quang and colleagues, and observed significantly higher efficiency compared with the ISO 15216-1 method and comparable efficiency with Method E, with less steps, and shorter hands-on time.


PeerJ ◽  
2017 ◽  
Vol 5 ◽  
pp. e3840 ◽  
Author(s):  
Ming-An Tsai ◽  
I-Hua Chen ◽  
Jiann-Hsiung Wang ◽  
Shih-Jen Chou ◽  
Tsung-Hsien Li ◽  
...  

Cytokines are fundamental for a functioning immune system, and thus potentially serve as important indicators of animal health. Quantitation of mRNA using quantitative reverse transcription polymerase chain reaction (qRT-PCR) is an established immunological technique. It is particularly suitable for detecting the expression of proteins against which monoclonal antibodies are not available. In this study, we developed a probe-based quantitative gene expression assay for immunological assessment of captive beluga whales (Delphinapterus leucas) that is one of the most common cetacean species on display in aquariums worldwide. Six immunologically relevant genes (IL-2Rα, -4, -10, -12, TNFα, and IFNγ) were selected for analysis, and two validated housekeeping genes (PGK1 and RPL4) with stable expression were used as reference genes. Sixteen blood samples were obtained from four animals with different health conditions and stored in RNAlater™ solution. These samples were used for RNA extraction followed by qRT-PCR analysis. Analysis of gene transcripts was performed by relative quantitation using the comparative Cq method with the integration of amplification efficiency and two reference genes. The expression levels of each gene in the samples from clinically healthy animals were normally distributed. Transcript outliers for IL-2Rα, IL-4, IL-12, TNFα, and IFNγ were noticed in four samples collected from two clinically unhealthy animals. This assay has the potential to identify immune system deviation from normal state, which is caused by health problems. Furthermore, knowing the immune status of captive cetaceans could help both trainers and veterinarians in implementing preventive approaches prior to disease onset.


2003 ◽  
Vol 3 (5-6) ◽  
pp. 1-7
Author(s):  
S. Oxtoby

The Clay Lane Water treatment works of Three Valleys Water, in the south east of England, is currently the world’s largest ultrafiltration works with a capacity of 160 Ml/d. It utilises ultrafiltration membranes constructed as hollow fibres with a number of membrane elements in a pressure housing. The plant has been operating since spring 2001. The decision to install the system was made in anticipation of the introduction of tighter regulations on Cryptosporidium in water supplies in the UK. Once a decision was made to proceed with a membrane system the ability to monitor the integrity of the system and to repair problems became a crucial design parameter that was a critical part of membrane selection. The need to include a system affected the design of the filtration units offered by manufacturers. The available systems for integrity testing are reviewed and the reasons for selecting the system adopted are discussed. These include particle counting and the dosing of test particulate loads. The different forms of air passage integrity tests are discussed and the displaced air flow system used is described. Once a failure has been detected it must be traced so that the fault can be repaired. This procedure is described together with the techniques of pin repair of damaged fibres. At Clay Lane and other membrane filtration sites the backwash water from membrane cleaning is recovered using a secondary membrane system. Currently the secondary system operates in the same integrity testing regime as the primary system and the secondary filtrate is returned ahead of the primary membrane system. The relative merits of this system, or the alternative of adding the recovered water to the filtrate are discussed.


Membranes ◽  
2019 ◽  
Vol 10 (1) ◽  
pp. 5 ◽  
Author(s):  
Mikael Sjölin ◽  
Johan Thuvander ◽  
Ola Wallberg ◽  
Frank Lipnizki

Molasses is a sugar mill by-product with low value that today is used primarily for animal feed. However, molasses contains large amounts of sucrose which, if purified, could be used for other purposes. In this study, purification by membrane filtration using ceramic tubular ultrafiltration (UF) and nanofiltration (NF) was examined. NF purifies sucrose by removing small compounds, whereas UF removes larger compounds. Based on our results, high filtration fluxes could be obtained, and it was possible to clean the membranes sufficiently from fouling compounds. Sucrose was separated from other compounds, but the separation efficiency was generally higher with diluted molasses compared with concentrated molasses. This could be explained by more severe fouling when filtering dilute molasses or potentially due to aggregate formations in the molasses as our analysis showed. Overall, this study shows the potential of ceramic UF and NF membranes for sucrose purification from molasses.


Cerâmica ◽  
2019 ◽  
Vol 65 (373) ◽  
pp. 28-34
Author(s):  
K. C. Nóbrega ◽  
S. S. S. Silva ◽  
L. V. Amorim ◽  
H. L. Lira ◽  
W. R. P. Costa

Abstract The aim of this work was to evaluate the influence of the chemical structure of carboxymethylcellulose (CMC) on the rheological performance and fluid loss of clay dispersions. The dispersions were prepared with a fixed content of bentonite clay (15 g/350 mL of water) and different concentrations of CMCs (0.5, 1.0, 2.0 g/350 mL of water). After aging for 24 h in ambient and static conditions, the dispersions were tested in a viscometer. Apparent and plastic viscosities, yield point and gel strength were obtained using the viscometer, according to Petrobras’ standard (EP-1EP-00011-A). The filtrate volume was determined using the API filter press. The results showed that the addition of long chain, low degree of substitution and lower substitution uniformity of CMC contribute to the flocculation phenomenon. In addition, the different chemical characteristics of CMC only influence fluid loss when the ionic strength of the dispersion is set to any other value than zero.


Desalination ◽  
2008 ◽  
Vol 227 (1-3) ◽  
pp. 111-119 ◽  
Author(s):  
E. Arkhangelsky ◽  
B. Steubing ◽  
E. Ben-Dov ◽  
A. Kushmaro ◽  
V. Gitis

Blood ◽  
2014 ◽  
Vol 124 (21) ◽  
pp. 4566-4566
Author(s):  
Olga Sala Torra ◽  
Lan Beppu ◽  
Susan Branford ◽  
Linda Fletcher ◽  
Gooley Ted ◽  
...  

Abstract In many parts of the world, diagnosis and monitoring of CML patients is limited by the availability and cost of molecular testing. In countries without molecular diagnostic capabilities, blood samples can be shipped to central labs, but this is both hampered by sample degradation, and the high costs of shipping. This study explores the method of directly spotting peripheral blood onto a paper template (dried blood spots), with subsequent shipping, RNA extraction, and BCR-ABL testing. Methods: Blood Spots and Shipment. We received dried blood spots from Australia and African countries by mail or courier, and blood from CML patients from our institution were also used for these experiments. 200μL of blood (PB) was pipetted onto Whatman 503 Protein Saver Cards (PSC; Sigma-Aldrich), where each card contains four 50μL spots. Cards were allowed to dry for at least 24 hours at room temperature. For mailing, PSCs were sealed into glassine envelopes with a packet of desiccant, and then placed inside a mailing envelope following DOT and IATA regulation for shipping non-regulated, exempt human specimens. RNA Extraction from Cards and %BCR-ABL determination. Blood spots were incubated with proteinase K followed by RNA isolation using RNeasy Mini Kits (Qiagen). Extracted RNA was quantified using a NanoDrop spectrometer (Thermo Scientific). %BCR-ABL was determined using the automated Cepheid GeneXpert platform or manual two-step quantitative RT-PCR on the 7900HT Fast Real-Time PCR System (Applied Biosystems). Results: Bench top time course: To test for effects of long transit times on RNA quality, we performed a time course study of cards at room temperature (RT) with 5 samples. For each sample, multiple cards were spotted with PB. The cards were then allowed to sit at RT for predetermined amounts of time, up to 42 days, before extracting RNA. We measured RNA integrity for one of the specimens (CML # 5) and found rapid degradation with the RIN number going from 8.7 for the fresh blood to 2.8 after 28 days on the card. However the amplification for both BCR-ABL and ABL differed less than one cycle between the fresh blood and the last time point by manual qRT-PCR (BCR-ABL Ct = 23.63 for fresh blood and 24.06 for day 28 PSC; ABL Ct = 26.69 for fresh blood and 27.64 for day 28 PSC). Figure 1 shows the results of the time course experiment for the 5 samples as a plot of ΔCt versus time in days. BCR-ABL qRT-PCR concordance studies: We compared the %BCR-ABL results obtained in fresh specimen at the institution sending the sample with the %BCR-ABL results we obtained from RNA extracted from PSC using the Cepheid GeneXpert. Paired evaluable results were available for 9 samples with a median WBC = 9.8 x 109/L (range: 3.37x109/L – 85.5x109/L). Samples were 8 to 49 days old at the time of extraction. The amount of RNA input into the GeneXpert reaction ranged from 38.75ng to 1μg. The %BCR-ABL detected ranged from 0.37% to 27% (see Table). The mean absolute difference between fresh blood and PSC BCR-ABL% is 2%; the relative mean percent change for BCR-ABL, using fresh blood as the reference is 13.1% (S.D., 31.2), P = 0.24. Conclusions and future directions: Dried blood spots are relatively inexpensive method to transport blood that preserves enough RNA stability to allow highly accurate BCR-ABL detection, when compared to results performed on an identical platform using fresh peripheral blood samples. Further studies are undergoing to accurately determine the sensitivity of this method and the feasibility of using regular mail for inexpensive transport of specimens. Table 1IDWBC (1000/μL)Sample Age at Spotting (Days)Sample Age at RNA extraction (Days)RNA ng/μlVolume GeneXPert (μL)Paper %BCR-ABL (IS)GeneXpertFresh Blood % BCR-ABL (IS) GeneXpertI1na010426349naI224.101311092745I38009181544naI47.4285102.4*3.1I55.50495241.92I63.61307.4225912I785.5130102102439I812.212912.415128.8I9na1281.5250.37*0.71I103.370273257.85.7I1115.912731102325I126.612714.415na2.3 *%BCR-ABL was manually calculated due to late ABL Cts because of low starting material. Figure 1 Figure 1. Disclosures No relevant conflicts of interest to declare.


Sign in / Sign up

Export Citation Format

Share Document