scholarly journals Real-Time Monitoring of Human Enterovirus (HEV)-Infected Cells and Anti-HEV 3C Protease Potency by Fluorescence Resonance Energy Transfer

2008 ◽  
Vol 53 (2) ◽  
pp. 748-755 ◽  
Author(s):  
Meng-Tian Tsai ◽  
Yun-Hsiang Cheng ◽  
Yu-Ning Liu ◽  
Nien-Chien Liao ◽  
Wen-Wen Lu ◽  
...  

ABSTRACT A real-time assay system that allows monitoring of intracellular human enterovirus (HEV) protease activity was established using the principle of fluorescence resonance energy transfer (FRET). It was accomplished by engineering cells to constitutively express a genetically encoded FRET probe. The FRET-based probe was designed to contain an enterovirus 71 3C protease (3Cpro) cleavage motif flanked by the FRET pair composed of green fluorescent protein 2 and red fluorescent protein 2 (DsRed2). Efficient FRET from the stable line was detected in a real-time manner by fluorescence microscopy, and the disruption of FRET was readily monitored upon HEV infection. The level of the repressed FRET was proportional to the input virus titer and the infection duration as measured by the fluorometric method. The FRET biosensor cell line was also responsive to other related HEV serotypes, but not to the phylogenetically distant herpes simplex virus, which was confirmed by Western blot analysis. The FRET biosensor was then utilized to develop a format for the determination of antiviral susceptibility, as the reduced FRET appeared to reflect viral replication. Evaluations of the FRET biosensor system with representative HEV serotypes demonstrated that their susceptibilities to a 3Cpro inhibitor, rupintrivir, were all accurately determined. In summary, this novel FRET-based system is a means for rapid detection, quantification, and drug susceptibility testing for HEVs, with potential for the development of a high-throughput screening assay.

2004 ◽  
Vol 279 (50) ◽  
pp. 52399-52405 ◽  
Author(s):  
Anne J. Smith ◽  
Mark A. Sanders ◽  
Brian R. Thompson ◽  
Constantine Londos ◽  
Fredric B. Kraemer ◽  
...  

Previousin vitrostudies have established that hormone sensitive lipase (HSL) and adipocyte fatty acid-binding protein (AFABP) form a physical complex that presumably positions the FABP to accept a product fatty acid generated during catalysis. To assess AFABP-HSL interaction within a cellular context, we have used lipocytes derived from 293 cells (C8PA cells) and examined physical association using fluorescence resonance energy transfer. Transfection of C8PA cells with cyan fluorescent protein (CFP)-HSL, yellow fluorescent protein (YFP)-adipocyte FABP, or YFP-liver FABP revealed that under basal conditions each protein was cytoplasmic. In the presence of 20 μmforskolin, CFP-HSL translocated to the triacylglycerol droplet, coincident with BODIPY-FA labeled depots. Fluorescence resonance energy transfer analysis demonstrated that CFP-HSL associated with YFP-adipocyte FABP in both basal and forskolin-treated cells. In contrast, little if any fluorescence resonance energy transfer could be detected between CFP-HSL and YFP-liver FABP. These results suggest that a pre-lipolysis complex containing at least AFABP and HSL exists and that the complex translocates to the surface of the lipid droplet.


2020 ◽  
Vol 10 (10) ◽  
pp. 3508
Author(s):  
Haijun Yu ◽  
Haoxiang Li ◽  
Yao Zhou ◽  
Shengmin Zhou ◽  
Ping Wang

In this paper, a fluorescence resonance energy transfer (FRET)-based sensor for ultra-sensitive detection of H2O2 was developed by utilizing the unique enzymatic properties of peroxiredoxin (Prx) to H2O2. Cyan and yellow fluorescent protein (CFP and YFP) were fused to Prx and mutant thioredoxin (mTrx), respectively. In the presence of H2O2, Prx was oxidized into covalent homodimer through disulfide bonds, which were further reduced by mTrx to form a stable mixed disulfide bond intermediate between CFP-Prx and mTrx-YFP, inducing FRET. A linear quantification range of 10–320 nM was obtained according to the applied protein concentrations and the detection limit (LOD) was determined to be as low as 4 nM. By the assistance of glucose oxidase to transform glucose into H2O2, the CFP-Prx/mTrx-YFP system (CPmTY) was further exploited for the detection of glucose in real sample with good performance, suggesting this CPmTY protein sensor is highly practical.


Sign in / Sign up

Export Citation Format

Share Document