Micrometer-sized electrically programmable shape-memory actuators for low-power microrobotics

2021 ◽  
Vol 6 (52) ◽  
pp. eabe6663 ◽  
Author(s):  
Qingkun Liu ◽  
Wei Wang ◽  
Michael F. Reynolds ◽  
Michael C. Cao ◽  
Marc Z. Miskin ◽  
...  

Shape-memory actuators allow machines ranging from robots to medical implants to hold their form without continuous power, a feature especially advantageous for situations where these devices are untethered and power is limited. Although previous work has demonstrated shape-memory actuators using polymers, alloys, and ceramics, the need for micrometer-scale electro–shape-memory actuators remains largely unmet, especially ones that can be driven by standard electronics (~1 volt). Here, we report on a new class of fast, high-curvature, low-voltage, reconfigurable, micrometer-scale shape-memory actuators. They function by the electrochemical oxidation/reduction of a platinum surface, creating a strain in the oxidized layer that causes bending. They bend to the smallest radius of curvature of any electrically controlled microactuator (~500 nanometers), are fast (<100-millisecond operation), and operate inside the electrochemical window of water, avoiding bubble generation associated with oxygen evolution. We demonstrate that these shape-memory actuators can be used to create basic electrically reconfigurable microscale robot elements including actuating surfaces, origami-based three-dimensional shapes, morphing metamaterials, and mechanical memory elements. Our shape-memory actuators have the potential to enable the realization of adaptive microscale structures, bio-implantable devices, and microscopic robots.

2013 ◽  
Vol 135 (11) ◽  
Author(s):  
Edwin Peraza-Hernandez ◽  
Darren Hartl ◽  
Edgar Galvan ◽  
Richard Malak

Origami engineering—the practice of creating useful three-dimensional structures through folding and fold-like operations on two-dimensional building-blocks—has the potential to impact several areas of design and manufacturing. In this article, we study a new concept for a self-folding system. It consists of an active, self-morphing laminate that includes two meshes of thermally-actuated shape memory alloy (SMA) wire separated by a compliant passive layer. The goal of this article is to analyze the folding behavior and examine key engineering tradeoffs associated with the proposed system. We consider the impact of several design variables including mesh wire thickness, mesh wire spacing, thickness of the insulating elastomer layer, and heating power. Response parameters of interest include effective folding angle, maximum von Mises stress in the SMA, maximum temperature in the SMA, maximum temperature in the elastomer, and radius of curvature at the fold line. We identify an optimized physical realization for maximizing folding capability under mechanical and thermal failure constraints. Furthermore, we conclude that the proposed self-folding system is capable of achieving folds of significant magnitude (as measured by the effective folding angle) as required to create useful 3D structures.


2003 ◽  
Vol 112 ◽  
pp. 1181-1184 ◽  
Author(s):  
I. Vahhi ◽  
S. Pulnev ◽  
A. Priadko

Author(s):  
Tianjiao Wang ◽  
Jun Zhao ◽  
Chuanxin Weng ◽  
Tong Wang ◽  
Yayun Liu ◽  
...  

Shape memory polymers (SMPs) that change shapes as designed by external stimuli have become one of the most promising materials as actuators, sensors, and deployable devices. However, their practical applications...


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Rino Saiga ◽  
Masayuki Uesugi ◽  
Akihisa Takeuchi ◽  
Kentaro Uesugi ◽  
Yoshio Suzuki ◽  
...  

AbstractBrain blood vessels constitute a micrometer-scale vascular network responsible for supply of oxygen and nutrition. In this study, we analyzed cerebral tissues of the anterior cingulate cortex and superior temporal gyrus of schizophrenia cases and age/gender-matched controls by using synchrotron radiation microtomography or micro-CT in order to examine the three-dimensional structure of cerebral vessels. Over 1 m of cerebral blood vessels was traced to build Cartesian-coordinate models, which were then used for calculating structural parameters including the diameter and curvature of the vessels. The distribution of vessel outer diameters showed a peak at 7–9 μm, corresponding to the diameter of the capillaries. Mean curvatures of the capillary vessels showed a significant correlation to the mean curvatures of neurites, while the mean capillary diameter was almost constant, independent of the cases. Our previous studies indicated that the neurites of schizophrenia cases are thin and tortuous compared to controls. The curved capillaries with a constant diameter should occupy a nearly constant volume, while neurons suffering from neurite thinning should have reduced volumes, resulting in a volumetric imbalance between the neurons and the vessels. We suggest that the observed structural correlation between neurons and blood vessels is related to neurovascular abnormalities in schizophrenia.


2020 ◽  
Vol 7 (4) ◽  
pp. 170-180
Author(s):  
Hongjie Bi ◽  
Xin Jia ◽  
Gaoyuan Ye ◽  
Zechun Ren ◽  
Haiying Yang ◽  
...  

Processes ◽  
2021 ◽  
Vol 9 (8) ◽  
pp. 1314
Author(s):  
Cunxiang Yang ◽  
Yiwei Ding ◽  
Hongbo Qiu ◽  
Bin Xiong

The turn-to-turn faults (TTF) are also inevitable in split-winding transformers. The distorted leakage field generated by the TTF current results in large axial forces and end thrusts in the fault windings as well as affecting other branch windings normal operation, so it is of significance to study TTF of split-winding transformers. In this paper, the characteristics analysis of the split-winding transformer under the TTFs of the low voltage winding at different positions are presented. A 3600 KVA four split-windings transformer is taken as an example. Then, a simplified three-dimensional simplified model is established, taking into account the forces of the per-turn coil. The nonlinear-transient field-circuit coupled finite element method is used for the model. The leakage field distribution under the TTFs of the low voltage winding at different positions is studied. The resultant force of the short-circuit winding and the force of the per-turn coil are obtained. Subsequently, the force and current relationship between the branch windings are analyzed. The results show that the TTF at the specific location has a great influence on the axial windings on the same core, and the distorted leakage magnetic field will cause excessive axial force and end thrust of the normal and short-circuit windings. These results can provide a basis for the short-circuit design of split-winding transformer.


1995 ◽  
Vol 48 (11S) ◽  
pp. S61-S67 ◽  
Author(s):  
Carlos E. S. Cesnik ◽  
Dewey H. Hodges

An asymptotically exact methodology, based on geometrically nonlinear, three-dimensional elasticity, is presented for cross-sectional analysis of initially curved and twisted, nonhomogeneous, anisotropic beams. Through accounting for all possible deformation in the three-dimensional representation, the analysis correctly accounts for the complex elastic coupling phenomena in anisotropic beams associated with shear deformation. The analysis is subject only to the restrictions that the strain is small relative to unity and that the maximum dimension of the cross section is small relative to the wave length of the deformation and to the minimum radius of curvature and/or twist. The resulting cross-sectional elastic constants exhibit second-order dependence on the initial curvature and twist. As is well known, the associated geometrically-exact, one-dimensional equilibrium and kinematical equations also depend on initial twist and curvature. The corrections to the stiffness model derived herein are also necessary in general for proper representation of initially curved and twisted beams.


1993 ◽  
Author(s):  
Robert W. Lashlee ◽  
Rajendra R. Damle ◽  
Vittal S. Rao ◽  
Frank J. Kern

Sign in / Sign up

Export Citation Format

Share Document