Direct electrosynthesis of pure aqueous H2O2 solutions up to 20% by weight using a solid electrolyte

Science ◽  
2019 ◽  
Vol 366 (6462) ◽  
pp. 226-231 ◽  
Author(s):  
Chuan Xia ◽  
Yang Xia ◽  
Peng Zhu ◽  
Lei Fan ◽  
Haotian Wang

Hydrogen peroxide (H2O2) synthesis generally requires substantial postreaction purification. Here, we report a direct electrosynthesis strategy that delivers separate hydrogen (H2) and oxygen (O2) streams to an anode and cathode separated by a porous solid electrolyte, wherein the electrochemically generated H+ and HO2– recombine to form pure aqueous H2O2 solutions. By optimizing a functionalized carbon black catalyst for two-electron oxygen reduction, we achieved >90% selectivity for pure H2O2 at current densities up to 200 milliamperes per square centimeter, which represents an H2O2 productivity of 3.4 millimoles per square centimeter per hour (3660 moles per kilogram of catalyst per hour). A wide range of concentrations of pure H2O2 solutions up to 20 weight % could be obtained by tuning the water flow rate through the solid electrolyte, and the catalyst retained activity and selectivity for 100 hours.

Author(s):  
D. A. Kamble ◽  
B. S. Gawali

Micro-convection is a strategic area in transport phenomena, since it is the basis for a wide range of miniaturized high-performance heat transfer applications. Surface area is one of the important parameter for high flux heat transfer in microchannel performance. This experimental study deals with heat transfer using triangular microchannel having hydraulic diameters of 321μm and 289μm. Experimentation is carried out for triangular microchannel set for different heat input and flow rate condition. Triangular microchannel are manufactured with EDM technology. Testing of microchannel under laminar flow is considered with different tip angle, spacing, and length of microchannels. The different microchannels made up of copper material with 29 microchannel each having three different sets of length of 50 mm, 70 mm and 90 mm respectively. Tip angles for triangular microchannel is varied 50 ° and 60 ° with width of 30 mm each respectively are analyzed numerically. Spacing between triangular microchannels is also varied and 300μm and 400μm are considered for the analysis. Water flow rate is considered laminar flow. The flow rate of water is varied from 0.0167 kg/sec to 0.167 kg/sce to carry away heat. It is observed that as hydraulic diameters increase the heat transfer coefficient decreases. As the heat input to microchannel increases from 10 Watt to 100 Watt the temperature drop across varies from 2° C to 22°C as water flow rate increases. The numerical analysis is done using computer C programming. Experimental result differ from theoretical for temperature drop with variation of 2°C to 5°C. It is also observed that in all triangular microchannels its geometry i.e. tip angle and hydraulic diameter are dominant parameters which influences on rate of heat transfer. With increasing channel depth, increases flow passage area therefore enhances heat transfer sufficiently. From experimentation a Nu number correlation is proposed with considering tip angle, length, spacing of microchannel and other related parameters.


2014 ◽  
Vol 6 ◽  
pp. 659051 ◽  
Author(s):  
Cem Onat

This paper addresses the water temperature PI control in condensing domestic boilers. The main challenge of this process under the controller design perspective is the fact that the dynamics of condensing boilers are strongly affected by the demanded water flow rate. First, a robust PI controller based on weighted geometrical center method is designed that stabilizes and achieves good performance for closed-loop system for a wide range of the water flow rate. Then, it is shown that if the water flow rate information is used to update the controller gains, through a technique known as gain scheduled control, the performance can be significantly improved. Important characteristics of these PI design approaches are that the resulting parameters are calculated numerically without using any graphical method or iterative optimization process and that it guarantees the stability of the closed-loop. Significantly, simulation results have demonstrated that the proposed tuning techniques can perform better for set point changes and load disturbance than other available methods in the literature.


Metals ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 682
Author(s):  
Eko Surojo ◽  
Aziz Harya Gumilang ◽  
Triyono Triyono ◽  
Aditya Rio Prabowo ◽  
Eko Prasetya Budiana ◽  
...  

Underwater wet welding (UWW) combined with the shielded metal arc welding (SMAW) method has proven to be an effective way of permanently joining metals that can be performed in water. This research was conducted to determine the effect of water flow rate on the physical and mechanical properties (tensile, hardness, toughness, and bending effect) of underwater welded bead on A36 steel plate. The control variables used were a welding speed of 4 mm/s, a current of 120 A, electrode E7018 with a diameter of 4 mm, and freshwater. The results show that variations in water flow affected defects, microstructure, and mechanical properties of underwater welds. These defects include spatter, porosity, and undercut, which occur in all underwater welding results. The presence of flow and an increased flow rate causes differences in the microstructure, increased porosity on the weld metal, and undercut on the UWW specimen. An increase in water flow rate causes the acicular ferrite microstructure to appear greater, and the heat-affected zone (HAZ) will form finer grains. The best mechanical properties are achieved by welding with the highest flow rate, with a tensile strength of 534.1 MPa, 3.6% elongation, a Vickers microhardness in the HAZ area of 424 HV, and an impact strength of 1.47 J/mm2.


Author(s):  
Afshin Goharzadeh ◽  
Keegan Fernandes

This paper presents an experimental investigation on a modified airlift pump. Experiments were undertaken as a function of air-water flow rate for two submergence ratios (ε=0.58 and 0.74), and two different riser geometries (i) straight pipe with a constant inner diameter of 19 mm and (ii) enlarged pipe with a sudden expanded diameter of 19 to 32 mm. These transparent vertical pipes, of 1 m length, were submerged in a transparent rectangular tank (0.45×0.45×1.1 m3). The compressed air was injected into the vertical pipe to lift the water from the reservoir. The flow map regime is established for both configurations and compared with previous studies. The two phase air-water flow structure at the expansion region is experimentally characterized. Pipeline geometry is found to have a significant influence on the output water flow rate. Using high speed photography and electrical conductivity probes, new flow regimes, such as “slug to churn” and “annular to churn” flow, are observed and their influence on the output water flow rate and efficiency are discussed. These experimental results provide fundamental insights into the physics of modified airlift pump.


Energies ◽  
2018 ◽  
Vol 11 (1) ◽  
pp. 112 ◽  
Author(s):  
Yonghong Guo ◽  
Huimin Wei ◽  
Xiaoru Yang ◽  
Weijia Wang ◽  
Xiaoze Du ◽  
...  

Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 167
Author(s):  
Hasan Alimoradi ◽  
Madjid Soltani ◽  
Pooriya Shahali ◽  
Farshad Moradi Kashkooli ◽  
Razieh Larizadeh ◽  
...  

In this study, a numerical and empirical scheme for increasing cooling tower performance is developed by combining the particle swarm optimization (PSO) algorithm with a neural network and considering the packing’s compaction as an effective factor for higher accuracies. An experimental setup is used to analyze the effects of packing compaction on the performance. The neural network is optimized by the PSO algorithm in order to predict the precise temperature difference, efficiency, and outlet temperature, which are functions of air flow rate, water flow rate, inlet water temperature, inlet air temperature, inlet air relative humidity, and packing compaction. The effects of water flow rate, air flow rate, inlet water temperature, and packing compaction on the performance are examined. A new empirical model for the cooling tower performance and efficiency is also developed. Finally, the optimized performance conditions of the cooling tower are obtained by the presented correlations. The results reveal that cooling tower efficiency is increased by increasing the air flow rate, water flow rate, and packing compaction.


Sign in / Sign up

Export Citation Format

Share Document