Assessment of Scapular Position

1993 ◽  
Vol 2 (1) ◽  
pp. 20-25 ◽  
Author(s):  
Lynne Neiers ◽  
Teddy W. Worrell

Assessment of posture is an integral component of the evaluation of patients with neck and shoulder dysfunctions. Protraction of the scapulae has been postulated to produce weakness of the shoulder musculature. Therefore, an accurate method is needed to assess scapular position in order to determine the effect of therapeutic intervention and classify dysfunction. The purpose of this study was to determine if an experienced clinician would accurately determine scapular position. Fifty subjects (age = 26 ±5.7 years, weight = 69.2 ±14.09 kg; height = 173.9 ±13.91 cm) participated in this study. The results revealed the following reliability coefficients: scapular distance (SD) intraclass correlation coefficient (ICC) = .80, scapular size (SS) ICC = .96, and normalized scapular abduction (NSA) (SD/SS) ICC = .34. These data demonstrate that NSA was not reproducible in this study. The authors hypothesize that NSA contains more measurement error because NSA is a ratio value in which both the numerator and denominator contain measurement error. Further study is needed before NSA values are used to determine scapular position or correlated NSA is used to force development of shoulder musculature.

Ultrasound ◽  
2019 ◽  
Vol 27 (3) ◽  
pp. 156-166 ◽  
Author(s):  
Vanessa L Kennedy ◽  
Carol A Flavell ◽  
Kenji Doma

A “free hand” real-time-ultrasound method is commonly applied to measure transversus abdominis. Potentially, this increases transversus abdominis measurement error due to uncontrolled variability in probe to skin force, inclination, and roll, particularly for novice examiners. This single-group repeated-measures reliability study compared the intra-rater reliability of transversus abdominis thickness and activation measurement by a novice examiner between free hand and a standardized probe force device method. The examiner captured ultrasound videos of transversus abdominis in a single session in healthy participants ( n =  33). Free hand ultrasound featured uncontrolled probe force, inclination, and roll, while probe force device method ultrasound standardized these parameters. Images of transversus abdominis at rest and contracted were measured and transversus abdominis activation calculated. Intraclass correlation coefficient, coefficient of variation, standard error of measurement, and worthwhile differences were calculated. The probe force device method resulted in greater reliability (intraclass correlation coefficient = 0.75–0.96) and lower measurement error (coefficient of variation = 8.89–28.7%) compared to free hand (intraclass correlation coefficient = 0.63–0.93; coefficient of variation = 6.52–29.4%). Reliability was good for all measurements except free hand TrA-C, which was moderate. TrA-C had the lowest reliability, followed by contracted thickness of the transverse abdominis, with resting thickness of the transverse abdominis being highest. Worthwhile differences were lower using a probe force device method versus free hand for resting thickness of the transverse abdominis and contracted thickness of the transverse abdominis and similar for TrA-C. Standardization using probe force device method ultrasound to measure transversus abdominis improved intra-rater reliability in a novice examiner. Use of a probe force device method is recommended to improve reliability through reduced sources of measurement error. Probe force device method intra- and inter-rater reliability in examiners of varying experience, in clinical populations, and to visualize other structures merits exploration.


2013 ◽  
Vol 93 (7) ◽  
pp. 935-941 ◽  
Author(s):  
Lydia Willemse ◽  
Merel A. Brehm ◽  
Vanessa A. Scholtes ◽  
Laura Jansen ◽  
Hester Woudenberg-Vos ◽  
...  

Background Children with cerebral palsy (CP) typically show muscle weakness of the lower extremities, which can be measured with the use of handheld dynamometry (HHD). Objective The purposes of this study were: (1) to determine test-retest reliability and measurement error of isometric lower-extremity strength measurements in children with CP with the use of HHD and (2) to assess implications for measurement design. Design A test-retest design was used. Methods Fourteen children with hemiplegic (n=6) or diplegic (n=8) spastic CP (Gross Motor Function Classification System levels I–III), ages 7 to 13 years, were assessed for isometric strength on 2 separate days (occasions) with the use of HHD, with 3 trials per muscle group. The intraclass correlation coefficient, standard error of measurement, and smallest detectable difference (SDD) were calculated for different measurement designs. Results Intraclass correlation coefficient values of single measurements for all muscle groups ranged from .70 to .90, and the SDD was large (>30%). Regarding measurement error, the largest source of variability was found for occasion. A 2-occasion mean decreased the SDD by 9% to 14%. For trials, a greater improvement in SDD was found when 2 trials were averaged instead of 3. A measurement design of 2 trials–2 occasions was superior to the often-used approach of 3 trials–1 occasion. Limitations The small sample size was the major study limitation. Conclusions Handheld dynamometry is reliable and can be used to detect changes in isometric muscle strength in children with CP when using the mean of at least 2 trials. To further improve reliability, taking the average of 2 occasions on separate days is recommended, depending on group size and muscle group.


2016 ◽  
Vol 2016 ◽  
pp. 1-6
Author(s):  
Bo Zhang ◽  
Jianjun Gu ◽  
Xiaoxiao Zhang ◽  
Bin Yang ◽  
Zheng Wang ◽  
...  

Purpose. To explore the probability and variation in biomechanical measurements of rabbit cornea by a modified Scheimpflug device.Methods. A modified Scheimpflug device was developed by imaging anterior segment of the model imitating the intact eye at various posterior pressures. The eight isolated rabbit corneas were mounted on the Barron artificial chamber and images of the anterior segment were taken at posterior pressures of 15, 30, 45, 60, and 75 mmHg by the device. The repeatability and reliability of the parameters including CCT, ACD, ACV, and CV were evaluated at each posterior pressure. All the variations of the parameters at the different posterior pressures were calculated.Results. All parameters showed good intraobserver reliability (Cronbach’s alpha; intraclass correlation coefficient,α, ICC > 0.96) and repeatability in the modified Scheimpflug device. With the increase of posterior pressures, the ratio of CCT decreased linearly and the bulk modulus gradually reduced to a platform. The increase of ACD was almost linear with the posterior pressures elevated.Conclusions. The modified Scheimpflug device was a valuable tool to investigate the biomechanics of the cornea. The posterior pressure 15–75 mmHg range produced small viscoelastic deformations and nearly linear pressure-deformation response in the rabbit cornea.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Lloyd Roberts ◽  
Tom Rozen ◽  
Deirdre Murphy ◽  
Adam Lawler ◽  
Mark Fitzgerald ◽  
...  

Abstract Background Multiple screening Duplex ultrasound scans (DUS) are performed in trauma patients at high risk of deep vein thrombosis (DVT) in the intensive care unit (ICU). Intensive care physician performed compression ultrasound (IP-CUS) has shown promise as a diagnostic test for DVT in a non-trauma setting. Whether IP-CUS can be used as a screening test in trauma patients is unknown. Our study aimed to assess the agreement between IP-CUS and vascular sonographer performed DUS for proximal lower extremity deep vein thrombosis (PLEDVT) screening in high-risk trauma patients in ICU. Methods A prospective observational study was conducted at the ICU of Alfred Hospital, a major trauma center in Melbourne, Australia, between Feb and Nov 2015. All adult major trauma patients admitted with high risk for DVT were eligible for inclusion. IP-CUS was performed immediately before or after DUS for PLEDVT screening. The paired studies were repeated twice weekly until the DVT diagnosis, death or ICU discharge. Written informed consent from the patient, or person responsible, or procedural authorisation, was obtained. The individuals performing the scans were blinded to the others’ results. The agreement analysis was performed using Cohen’s Kappa statistics and intraclass correlation coefficient for repeated binary measurements. Results During the study period, 117 patients had 193 pairs of scans, and 45 (39%) patients had more than one pair of scans. The median age (IQR) was 47 (28–68) years with 77% males, mean (SD) injury severity score 27.5 (9.53), and a median (IQR) ICU length of stay 7 (3.2–11.6) days. There were 16 cases (13.6%) of PLEDVT with an incidence rate of 2.6 (1.6–4.2) cases per 100 patient-days in ICU. The overall agreement was 96.7% (95% CI 94.15–99.33). The Cohen’s Kappa between the IP-CUS and DUS was 0.77 (95% CI 0.59–0.95), and the intraclass correlation coefficient for repeated binary measures was 0.75 (95% CI 0.67–0.81). Conclusions There is a substantial agreement between IP-CUS and DUS for PLEDVT screening in trauma patients in ICU with high risk for DVT. Large multicentre studies are needed to confirm this finding.


Author(s):  
Daniela Claessens ◽  
Alexander K. Schuster ◽  
Ronald V. Krüger ◽  
Marian Liegl ◽  
Laila Singh ◽  
...  

AbstractIn this study, the test-retest-reliability as one aspect of reliability of metamorphopsia measurements using a computer-based measuring method was determined in patients with macular diseases. Metamorphopsia amplitude, position, and area were quantified using AMD – A Metamorphopsia Detector software (app4eyes GmbH & Co. KG, Germany) in patients with diabetic, myopic, or uveitic macular edema, intermediate or neovascular age-associated macular degeneration, epiretinal membrane, vitelliform maculopathy, Irvine-Gass syndrome, or macular edema due to venous retinal occlusion. The intraclass correlation coefficient (ICC) was calculated in order to determine the repeatability of two repeated measurements and was used as an indicator of the reliability of the measurements. In this study, metamorphopsia measurements were conducted on 36 eyes with macular diseases. Metamorphopsia measurements made using AMD – A Metamorphopsia Detector software were highly reliable and repeatable in patients with maculopathies. The intraclass correlation coefficient of all indices was excellent (0.95 – 0.97). For diseases of the vitreoretinal interface or macular diseases with intra- or subretinal edema, this metamorphopsia measurement represents a supplement for visual function testing in the clinic, as well as in clinical studies.