The contribution of high-frequency information to fine-grained speech perception in cochlear-implant-simulated speech

2012 ◽  
Vol 132 (3) ◽  
pp. 1966-1966
Author(s):  
Ashley Farris-Trimble ◽  
Bob McMurray
2019 ◽  
Vol 30 (4) ◽  
pp. 751-784 ◽  
Author(s):  
David Lorenz ◽  
David Tizón-Couto

Abstract Frequently used linguistic structures become entrenched in memory; this is often assumed to make their consecutive parts more predictable, as well as fuse them into a single unit (chunking). High frequency moreover leads to a propensity for phonetic reduction. We present a word recognition experiment which tests how frequency information (string frequency, transitional probability) interacts with reduction in speech perception. Detection of the element to is tested in V-to-Vinf sequences in English (e.g., need to Vinf), where to can undergo reduction (“needa”). Results show that reduction impedes recognition, but this can be mitigated by the predictability of the item. Recognition generally benefits from surface frequency, while a modest chunking effect is found in delayed responses to reduced forms of high-frequency items. Transitional probability shows a facilitating effect on reduced but not on full forms. Reduced forms also pose more difficulty when the phonological context obscures the onset of to. We conclude that listeners draw on frequency information in a predictive manner to cope with reduction. High-frequency structures are not inevitably perceived as chunks, but depend on cues in the phonetic form – reduction leads to perceptual prominence of the whole over the parts and thus promotes a holistic access.


2016 ◽  
Vol 59 (1) ◽  
pp. 99-109 ◽  
Author(s):  
Jennifer R. Fowler ◽  
Jessica L. Eggleston ◽  
Kelly M. Reavis ◽  
Garnett P. McMillan ◽  
Lina A. J. Reiss

PurposeThe objective was to determine whether speech perception could be improved for bimodal listeners (those using a cochlear implant [CI] in one ear and hearing aid in the contralateral ear) by removing low-frequency information provided by the CI, thereby reducing acoustic–electric overlap.MethodSubjects were adult CI subjects with at least 1 year of CI experience. Nine subjects were evaluated in the CI-only condition (control condition), and 26 subjects were evaluated in the bimodal condition. CIs were programmed with 4 experimental programs in which the low cutoff frequency (LCF) was progressively raised. Speech perception was evaluated using Consonant-Nucleus-Consonant words in quiet, AzBio sentences in background babble, and spondee words in background babble.ResultsThe CI-only group showed decreased speech perception in both quiet and noise as the LCF was raised. Bimodal subjects with better hearing in the hearing aid ear (< 60 dB HL at 250 and 500 Hz) performed best for words in quiet as the LCF was raised. In contrast, bimodal subjects with worse hearing (> 60 dB HL at 250 and 500 Hz) performed similarly to the CI-only group.ConclusionsThese findings suggest that reducing low-frequency overlap of the CI and contralateral hearing aid may improve performance in quiet for some bimodal listeners with better hearing.


2003 ◽  
Vol 14 (10) ◽  
pp. 582-591 ◽  
Author(s):  
Alexandra Weatherby ◽  
Katherine R. Henshall ◽  
Colette M. McKay

The aim of this study was to investigate the effects on speech perception of manipulating filter gains in a cochlear implant speech processor. Five implantees, who use the CI22 implant and Spectra processor manufactured by Cochlear Ltd, participated. Four experimental maps were created that were identical to their clinical map except for the profile of gains across the filters. Experimental gain profiles had rising or falling gains across the frequency range, or emphasized or de-emphasized the middle frequencies, relative to the clinical map. Perception of CNC (consonant-vowel-consonant) words at 70 dB SPL was significantly better with the clinical map than with all experimental maps, whereas at the lower level (60 dB SPL) there was minimal difference between the maps, with the low-frequency emphasis map giving significantly better scores than the high-frequency emphasis map. Perception of sentences at 70 dB SPL with a signal-to-noise ratio of +10 dB was better with the high-frequency emphasis map than with the low-frequency emphasis map. None of these best-conditions, however, were statistically better than the clinical map. The results highlighted the importance of signal audibility for speech perception with cochlear implants.


2018 ◽  
Vol 39 (04) ◽  
pp. 414-427 ◽  
Author(s):  
Christopher Welch ◽  
Margaret Dillon ◽  
Harold Pillsbury

AbstractHearing loss affects 30 million people in the United States, and a subset of these patients have normal low-frequency hearing and ski-sloped high-frequency hearing loss. For these patients, hearing aids alone may not provide adequate benefit. Cochlear implantation alone has been utilized to improve speech perception. The addition of high-frequency electric hearing to low-frequency acoustic hearing in these patients is beneficial. Technical improvements have allowed preservation of low-frequency hearing in cochlear implant recipients, allowing for electric and acoustic stimulation in the same ear with significant improvements in speech perception, sound localization, music appreciation, and quality of life.


2010 ◽  
Vol 10 ◽  
pp. 329-339 ◽  
Author(s):  
Torsten Rahne ◽  
Michael Ziese ◽  
Dorothea Rostalski ◽  
Roland Mühler

This paper describes a logatome discrimination test for the assessment of speech perception in cochlear implant users (CI users), based on a multilingual speech database, the Oldenburg Logatome Corpus, which was originally recorded for the comparison of human and automated speech recognition. The logatome discrimination task is based on the presentation of 100 logatome pairs (i.e., nonsense syllables) with balanced representations of alternating “vowel-replacement” and “consonant-replacement” paradigms in order to assess phoneme confusions. Thirteen adult normal hearing listeners and eight adult CI users, including both good and poor performers, were included in the study and completed the test after their speech intelligibility abilities were evaluated with an established sentence test in noise. Furthermore, the discrimination abilities were measured electrophysiologically by recording the mismatch negativity (MMN) as a component of auditory event-related potentials. The results show a clear MMN response only for normal hearing listeners and CI users with good performance, correlating with their logatome discrimination abilities. Higher discrimination scores for vowel-replacement paradigms than for the consonant-replacement paradigms were found. We conclude that the logatome discrimination test is well suited to monitor the speech perception skills of CI users. Due to the large number of available spoken logatome items, the Oldenburg Logatome Corpus appears to provide a useful and powerful basis for further development of speech perception tests for CI users.


2021 ◽  
Vol 37 (1) ◽  
Author(s):  
Mai M. El Ghazaly ◽  
Mona I. Mourad ◽  
Nesrine H. Hamouda ◽  
Mohamed A. Talaat

Abstract Background Speech perception in cochlear implants (CI) is affected by frequency resolution, exposure time, and working memory. Frequency discrimination is especially difficult in CI. Working memory is important for speech and language development and is expected to contribute to the vast variability in CI speech reception and expression outcome. The aim of this study is to evaluate CI patients’ consonants discrimination that varies in voicing, manner, and place of articulation imparting differences in pitch, time, and intensity, and also to evaluate working memory status and its possible effect on consonant discrimination. Results Fifty-five CI patients were included in this study. Their aided thresholds were less than 40 dBHL. Consonant speech discrimination was assessed using Arabic consonant discrimination words. Working memory was assessed using Test of Memory and Learning-2 (TOMAL-2). Subjects were divided according to the onset of hearing loss into prelingual children and postlingual adults and teenagers. Consonant classes studied were fricatives, stops, nasals, and laterals. Performance on the high frequency CVC words was 64.23% ± 17.41 for prelinguals and 61.70% ± 14.47 for postlinguals. These scores were significantly lower than scores on phonetically balanced word list (PBWL) of 79.94% ± 12.69 for prelinguals and 80.80% ± 11.36 for postlinguals. The lowest scores were for the fricatives. Working memory scores were strongly and positively correlated with speech discrimination scores. Conclusions Consonant discrimination using high frequency weighted words can provide a realistic tool for assessment of CI speech perception. Working memory skills showed a strong positive relationship with speech discrimination abilities in CI.


2021 ◽  
Vol 11 (2) ◽  
pp. 220-226
Author(s):  
Yew-Song Cheng ◽  
Mario A. Svirsky

The presence of spiral ganglion cells (SGCs) is widely accepted to be a prerequisite for successful speech perception with a cochlear implant (CI), because SGCs provide the only known conduit between the implant electrode and the central auditory system. By extension, it has been hypothesized that the number of SGCs might be an important factor in CI outcomes. An impressive body of work has been published on findings from the laborious process of collecting temporal bones from CI users and counting the number of SGCs to correlate those numbers with speech perception scores, but the findings thus far have been conflicting. We performed a meta-analysis of all published studies with the hope that combining existing data may help us reach a more definitive conclusion about the relationship between SGC count and speech perception scores in adults.


1993 ◽  
Vol 94 (6) ◽  
pp. 3178-3189 ◽  
Author(s):  
R. J. M. van Hoesel ◽  
Y. C. Tong ◽  
R. D. Hollow ◽  
G. M. Clark

2015 ◽  
Vol 24 (4) ◽  
pp. 462-468 ◽  
Author(s):  
Jessica J. Messersmith ◽  
Lindsey E. Jorgensen ◽  
Jessica A. Hagg

Purpose The purpose of this study was to determine whether an alternate fitting strategy, specifically adjustment to gains in a hearing aid (HA), would improve performance in patients who experienced poorer performance in the bimodal condition when the HA was fit to traditional targets. Method This study was a retrospective chart review from a local clinic population seen during a 6-month period. Participants included 6 users of bimodal stimulation. Two performed poorer in the cochlear implant (CI) + HA condition than in the CI-only condition. One individual performed higher in the bimodal condition, but the overall performance was low. Three age range–matched users whose performance increased when the HA was used in conjunction with a CI were also included. The HA gain was reduced beyond 2000 Hz. Speech perception scores were obtained pre- and postmodification to the HA fitting. Results All listeners whose HA was programmed using the modified approach demonstrated improved speech perception scores with the modified HA fit in the bimodal condition when compared with the traditional HA fit in the bimodal condition. Conclusion Modifications to gains above 2000 Hz in the HA may improve performance for bimodal listeners who perform more poorly in the bimodal condition when the HA is fit to traditional targets.


Sign in / Sign up

Export Citation Format

Share Document