Perceptually optimized gain function for cochlear implant signal-to-noise ratio based noise reduction

2012 ◽  
Vol 131 (1) ◽  
pp. 327-336 ◽  
Author(s):  
Stefan J. Mauger ◽  
Pam W. Dawson ◽  
Adam A. Hersbach
2015 ◽  
Vol 23 (5) ◽  
pp. 6976 ◽  
Author(s):  
Keigo Kamada ◽  
Yosuke Ito ◽  
Sunao Ichihara ◽  
Natsuhiko Mizutani ◽  
Tetsuo Kobayashi

2020 ◽  
Vol 24 ◽  
pp. 233121652097034
Author(s):  
Florian Langner ◽  
Andreas Büchner ◽  
Waldo Nogueira

Cochlear implant (CI) sound processing typically uses a front-end automatic gain control (AGC), reducing the acoustic dynamic range (DR) to control the output level and protect the signal processing against large amplitude changes. It can also introduce distortions into the signal and does not allow a direct mapping between acoustic input and electric output. For speech in noise, a reduction in DR can result in lower speech intelligibility due to compressed modulations of speech. This study proposes to implement a CI signal processing scheme consisting of a full acoustic DR with adaptive properties to improve the signal-to-noise ratio and overall speech intelligibility. Measurements based on the Short-Time Objective Intelligibility measure and an electrodogram analysis, as well as behavioral tests in up to 10 CI users, were used to compare performance with a single-channel, dual-loop, front-end AGC and with an adaptive back-end multiband dynamic compensation system (Voice Guard [VG]). Speech intelligibility in quiet and at a +10 dB signal-to-noise ratio was assessed with the Hochmair–Schulz–Moser sentence test. A logatome discrimination task with different consonants was performed in quiet. Speech intelligibility was significantly higher in quiet for VG than for AGC, but intelligibility was similar in noise. Participants obtained significantly better scores with VG than AGC in the logatome discrimination task. The objective measurements predicted significantly better performance estimates for VG. Overall, a dynamic compensation system can outperform a single-stage compression (AGC + linear compression) for speech perception in quiet.


2012 ◽  
Vol 226-228 ◽  
pp. 237-240 ◽  
Author(s):  
Mei Jun Zhang ◽  
Hao Chen ◽  
Chuang Wang ◽  
Qing Cao

In order to extract effectively detection signals in the noise background for non-stationary signal.On the basis of EEMD, improved EEMD is put forward, the improve EEMD threshold noise reduction is researched in this paper.The simulation signal compared the noise reduction effect of the wavelet,EMD,EEMD,and the improved EEMD. The improved EEMD threshold noise reduction have the best noise reduction result , the highest signal-to-noise ratio, the smallest standard deviation error.After the improved EEMD threshold noise reduction , the measurement signal time domain waveform smooth. More high frequency noise was obviously reduced in Hilbert time- frequency spectrum. Signal-to-noise ratio significantly improve, and signal characteristics are very clear.


2021 ◽  
pp. 019459982110492
Author(s):  
Allan M. Henslee ◽  
Christopher R. Kaufmann ◽  
Matt D. Andrick ◽  
Parker T. Reineke ◽  
Viral D. Tejani ◽  
...  

Objective Electrocochleography (ECochG) is increasingly being used during cochlear implant (CI) surgery to detect and mitigate insertion-related intracochlear trauma, where a drop in ECochG signal has been shown to correlate with a decline in hearing outcomes. In this study, an ECochG-guided robotics-assisted CI insertion system was developed and characterized that provides controlled and consistent electrode array insertions while monitoring and adapting to real-time ECochG signals. Study Design Experimental research. Setting A research laboratory and animal testing facility. Methods A proof-of-concept benchtop study evaluated the ability of the system to detect simulated ECochG signal changes and robotically adapt the insertion. Additionally, the ECochG-guided insertion system was evaluated in a pilot in vivo sheep study to characterize the signal-to-noise ratio and amplitude of ECochG recordings during robotics-assisted insertions. The system comprises an electrode array insertion drive unit, an extracochlear recording electrode module, and a control console that interfaces with both components and the surgeon. Results The system exhibited a microvolt signal resolution and a response time <100 milliseconds after signal change detection, indicating that the system can detect changes and respond faster than a human. Additionally, animal results demonstrated that the system was capable of recording ECochG signals with a high signal-to-noise ratio and sufficient amplitude. Conclusion An ECochG-guided robotics-assisted CI insertion system can detect real-time drops in ECochG signals during electrode array insertions and immediately alter the insertion motion. The system may provide a surgeon the means to monitor and reduce CI insertion–related trauma beyond manual insertion techniques for improved CI hearing outcomes.


Geophysics ◽  
2020 ◽  
Vol 85 (3) ◽  
pp. V249-V256
Author(s):  
Kai Lu ◽  
Zhaolun Liu ◽  
Sherif Hanafy ◽  
Gerard Schuster

To image deeper portions of the earth, geophysicists must record reflection data with much greater source-receiver offsets. The problem with these data is that the signal-to-noise ratio (S/N) significantly diminishes with greater offset. In many cases, the poor S/N makes the far-offset reflections imperceptible on the shot records. To mitigate this problem, we have developed supervirtual reflection interferometry (SVI), which can be applied to far-offset reflections to significantly increase their S/N. The key idea is to select the common pair gathers where the phases of the correlated reflection arrivals differ from one another by no more than a quarter of a period so that the traces can be coherently stacked. The traces are correlated and summed together to create traces with virtual reflections, which in turn are convolved with one another and stacked to give the reflection traces with much stronger S/Ns. This is similar to refraction SVI except far-offset reflections are used instead of refractions. The theory is validated with synthetic tests where SVI is applied to far-offset reflection arrivals to significantly improve their S/N. Reflection SVI is also applied to a field data set where the reflections are too noisy to be clearly visible in the traces. After the implementation of reflection SVI, the normal moveout velocity can be accurately picked from the SVI-improved data, leading to a successful poststack migration for this data set.


Sign in / Sign up

Export Citation Format

Share Document