Pure‐Tone Masking in the Cochlear Nerve of the Golden Hamster

1965 ◽  
Vol 37 (6) ◽  
pp. 1200-1200
Author(s):  
Alfred Finck
1977 ◽  
Vol 45 (1) ◽  
pp. 35-38
Author(s):  
James R. Nevitt ◽  
Wib Truby ◽  
Arthur E. Harriman

The purpose of the study was to investigate the effect of ultrasonic pure tone on Mesocricetus auratus, a Murine rodent that does not organize rigidly into colonies as do some cricetid rodents. Subjects were 4 male and 4 female adult golden hamsters. All animals were trained to bar-press in a modified operant chamber to escape 24-v D.C. footshock. An experimental group was exposed to a 30-kHz tone at 60 dB during testing in the operant chamber with footshock absent. Similar testing trials were also given to assess the effect of ultrasonic sound on anal body temperature. It was noted that the experimental group demonstrated both behavioral arousal by bar-pressing significantly more often than controls ( F = 6.95, df = 1/6, p > .05) and physiological arousal by increased body temperature ( F = 6.88, df = 1/6, p > .05).


2016 ◽  
Vol 21 (5) ◽  
pp. 286-295 ◽  
Author(s):  
Mario Sanna ◽  
María del Mar Medina ◽  
Aldin Macak ◽  
Gianluca Rossi ◽  
Valerio Sozzi ◽  
...  

Objective: To report the hearing results of cochlear implantation simultaneous to vestibular schwannoma (VS) resection by means of a translabyrinthine approach in patients with normal contralateral hearing. Methods: This was a prospective study including adults with sporadic VS. Tumors were resected by means of a modified translabyrinthine approach with preservation of the cochlear nerve. Results: A total of 13 patients underwent cochlear implantation. At 14 months, the mean pure-tone audiogram was 56 dB. The mean speech recognition was 80%. Cochlear implantation provides monaural and binaural benefits in all the conditions tested, including sound localization. Conclusions: Cochlear implantation can be safely performed simultaneously to VS resection with satisfactory hearing results provided that the cochlear nerve is anatomically intact.


1984 ◽  
Vol 15 (4) ◽  
pp. 289-294
Author(s):  
Martin S. Robinette ◽  
Robert H. Brey

A transformer mixing network is described which allows the calibration of broad-band masking for portable audiometers that lack a built-in mixing network. For many instruments the transformer network is preferable to the resistive network previously published.


2020 ◽  
Vol 29 (4) ◽  
pp. 685-690
Author(s):  
C. S. Vanaja ◽  
Miriam Soni Abigail

Purpose Misophonia is a sound tolerance disorder condition in certain sounds that trigger intense emotional or physiological responses. While some persons may experience misophonia, a few patients suffer from misophonia. However, there is a dearth of literature on audiological assessment and management of persons with misophonia. The purpose of this report is to discuss the assessment of misophonia and highlight the management option that helped a patient with misophonia. Method A case study of a 26-year-old woman with the complaint of decreased tolerance to specific sounds affecting quality of life is reported. Audiological assessment differentiated misophonia from hyperacusis. Management included retraining counseling as well as desensitization and habituation therapy based on the principles described by P. J. Jastreboff and Jastreboff (2014). A misophonia questionnaire was administered at regular intervals to monitor the effectiveness of therapy. Results A detailed case history and audiological evaluations including pure-tone audiogram and Johnson Hyperacusis Index revealed the presence of misophonia. The patient benefitted from intervention, and the scores of the misophonia questionnaire indicated a decrease in the severity of the problem. Conclusions It is important to differentially diagnose misophonia and hyperacusis in persons with sound tolerance disorders. Retraining counseling as well as desensitization and habituation therapy can help patients who suffer from misophonia.


Author(s):  
Nuriye Yıldırım Gökay ◽  
Bülent Gündüz ◽  
Fatih Söke ◽  
Recep Karamert

Purpose The effects of neurological diseases on the auditory system have been a notable issue for investigators because the auditory pathway is closely associated with neural systems. The purposes of this study are to evaluate the efferent auditory system function and hearing quality in Parkinson's disease (PD) and to compare the findings with age-matched individuals without PD to present a perspective on aging. Method The study included 35 individuals with PD (mean age of 48.50 ± 8.00 years) and 35 normal-hearing peers (mean age of 49 ± 10 years). The following tests were administered for all participants: the first section of the Speech, Spatial and Qualities of Hearing Scale; pure-tone audiometry, speech audiometry, tympanometry, and acoustic reflexes; and distortion product otoacoustic emissions (DPOAEs) and contralateral suppression of DPOAEs. SPSS Version 25 was used for statistical analyses, and values of p < .05 were considered statistically significant. Results There were no statistically significant differences in the pure-tone audiometry thresholds and DPOAE responses between the individuals with PD and their normal-hearing peers ( p = .732). However, statistically significant differences were found between the groups in suppression levels of DPOAEs and hearing quality ( p < .05). In addition, a statistically significant and positive correlation was found between the amount of suppression at some frequencies and the Speech, Spatial and Qualities of Hearing Scale scores. Conclusions This study indicates that medial olivocochlear efferent system function and the hearing quality of individuals with PD were affected adversely due to the results of PD pathophysiology on the hearing system. For optimal intervention and follow-up, tasks related to hearing quality in daily life can also be added to therapies for PD.


1965 ◽  
Vol 8 (4) ◽  
pp. 323-347
Author(s):  
Robert Goldstein ◽  
Benjamin RosenblÜt

Electrodermal and electroencephalic responsivity to sound and to light was studied in 96 normal-hearing adults in three separate sessions. The subjects were subdivided into equal groups of white men, white women, colored men, and colored women. A 1 000 cps pure tone was the conditioned stimulus in two sessions and white light was used in a third session. Heat was the unconditioned stimulus in all sessions. Previously, an inverse relation had been found in white men between the prominence of alpha rhythm in the EEG and the ease with which electrodermal responses could be elicited. This relation did not hold true for white women. The main purpose of the present study was to answer the following questions: (1) are the previous findings on white subjects applicable to colored subjects? (2) are subjects who are most (or least) responsive electrophysiologically on one day equally responsive (or unresponsive) on another day? and (3) are subjects who are most (or least) responsive to sound equally responsive (or unresponsive) to light? In general, each question was answered affirmatively. Other factors influencing responsivity were also studied.


1999 ◽  
Vol 24 (4) ◽  
pp. 377-383
Author(s):  
G. A. van zanten ◽  
A. van de sande ◽  
M. P. brocaar

2020 ◽  
Vol 31 (2) ◽  
pp. 81-86
Author(s):  
Wido Nager ◽  
Tilla Franke ◽  
Tobias Wagner-Altendorf ◽  
Eckart Altenmüller ◽  
Thomas F. Münte

Abstract. Playing a musical instrument professionally has been shown to lead to structural and functional neural adaptations, making musicians valuable subjects for neuroplasticity research. Here, we follow the hypothesis that specific musical demands further shape neural processing. To test this assumption, we subjected groups of professional drummers, professional woodwind players, and nonmusicians to pure tone sequences and drum sequences in which infrequent anticipations of tones or drum beats had been inserted. Passively listening to these sequences elicited a mismatch negativity to the temporally deviant stimuli which was greater in the musicians for tone series and particularly large for drummers for drum sequences. In active listening conditions drummers more accurately and more quickly detected temporally deviant stimuli.