Speech recognition in noise as a function of the number of spectral channels: Comparison of acoustic hearing and cochlear implants

2001 ◽  
Vol 110 (2) ◽  
pp. 1150-1163 ◽  
Author(s):  
Lendra M. Friesen ◽  
Robert V. Shannon ◽  
Deniz Baskent ◽  
Xiaosong Wang
2004 ◽  
Vol 115 (4) ◽  
pp. 1729-1735 ◽  
Author(s):  
Christopher W. Turner ◽  
Bruce J. Gantz ◽  
Corina Vidal ◽  
Amy Behrens ◽  
Belinda A. Henry

2009 ◽  
Vol 20 (07) ◽  
pp. 409-421 ◽  
Author(s):  
Jace Wolfe ◽  
Erin C. Schafer ◽  
Benjamin Heldner ◽  
Hans Mülder ◽  
Emily Ward ◽  
...  

Background: Use of personal frequency-modulated (FM) systems significantly improves speech recognition in noise for users of cochlear implants (CIs). Previous studies have shown that the most appropriate gain setting on the FM receiver may vary based on the listening situation and the manufacturer of the CI system. Unlike traditional FM systems with fixed-gain settings, Dynamic FM automatically varies the gain of the FM receiver with changes in the ambient noise level. There are no published reports describing the benefits of Dynamic FM use for CI recipients or how Dynamic FM performance varies as a function of CI manufacturer. Purpose: To evaluate speech recognition of Advanced Bionics Corporation or Cochlear Corporation CI recipients using Dynamic FM vs. a traditional FM system and to examine the effects of Autosensitivity on the FM performance of Cochlear Corporation recipients. Research Design: A two-group repeated-measures design. Participants were assigned to a group according to their type of CI. Study Sample: Twenty-five subjects, ranging in age from 8 to 82 years, met the inclusion criteria for one or more of the experiments. Thirteen subjects used Advanced Bionics Corporation, and 12 used Cochlear Corporation implants. Intervention: Speech recognition was assessed while subjects used traditional, fixed-gain FM systems and Dynamic FM systems. Data Collection and Analysis: In Experiments 1 and 2, speech recognition was evaluated with a traditional, fixed-gain FM system and a Dynamic FM system using the Hearing in Noise Test sentences in quiet and in classroom noise. A repeated-measures analysis of variance (ANOVA) was used to evaluate effects of CI manufacturer (Advanced Bionics and Cochlear Corporation), type of FM system (traditional and dynamic), noise level, and use of Autosensitivity for users of Cochlear Corporation implants. Experiment 3 determined the effects of Autosensitivity on speech recognition of Cochlear Corporation implant recipients when listening through the speech processor microphone with the FM system muted. A repeated-measures ANOVA was used to examine the effects of signal-to-noise ratio and Autosensitivity. Results: In Experiment 1, use of Dynamic FM resulted in better speech recognition in noise for Advanced Bionics recipients relative to traditional FM at noise levels of 65, 70, and 75 dB SPL. Advanced Bionics recipients obtained better speech recognition in noise with FM use when compared to Cochlear Corporation recipients. When Autosensitivity was enabled in Experiment 2, the performance of Cochlear Corporation recipients was equivalent to that of Advanced Bionics recipients, and Dynamic FM was significantly better than traditional FM. Results of Experiment 3 indicate that use of Autosensitivity improves speech recognition in noise of signals directed to the speech processor relative to no Autosensitivity. Conclusions: Dynamic FM should be considered for use with persons with CIs to improve speech recognition in noise. At default CI settings, FM performance is better for Advanced Bionics recipients when compared to Cochlear Corporation recipients, but use of Autosensitivity by Cochlear Corporation users results in equivalent group performance.


2012 ◽  
Vol 23 (07) ◽  
pp. 501-509 ◽  
Author(s):  
Erin C. Schafer ◽  
Jody Pogue ◽  
Tyler Milrany

Background: Speech recognition abilities of adults and children using cochlear implants (CIs) are significantly degraded in the presence of background noise, making this an important area of study and assessment by CI manufacturers, researchers, and audiologists. However, at this time there are a limited number of fixed-intensity sentence recognition tests available that also have multiple, equally intelligible lists in noise. One measure of speech recognition, the AzBio Sentence Test, provides 10-talker babble on the commercially available compact disc; however, there is no published evidence to support equivalency of the 15-sentence lists in noise for listeners with normal hearing (NH) or CIs. Furthermore, there is limited or no published data on the reliability, validity, and normative data for this test in noise for listeners with CIs or NH. Purpose: The primary goals of this study were to examine the equivalency of the AzBio Sentence Test lists at two signal-to-noise ratios (SNRs) in participants with NH and at one SNR for participants with CIs. Analyses were also conducted to establish the reliability, validity, and preliminary normative data for the AzBio Sentence Test for listeners with NH and CIs. Research Design: A cross-sectional, repeated measures design was used to assess speech recognition in noise for participants with NH or CIs. Study Sample: The sample included 14 adults with NH and 12 adults or adolescents with Cochlear Freedom CI sound processors. Participants were recruited from the University of North Texas clinic population or from local CI centers. Data Collection and Analysis: Speech recognition was assessed using the 15 lists of the AzBio Sentence Test and the 10-talker babble. With the intensity of the sentences fixed at 73 dB SPL, listeners with NH were tested at 0 and −3 dB SNRs, and participants with CIs were tested at a +10 dB SNR. Repeated measures analysis of variance (ANOVA) was used to analyze the data. Results: The primary analyses revealed significant differences in performance across the 15 lists on the AzBio Sentence Test for listeners with NH and CIs. However, a follow-up analysis revealed no significant differences in performance across 10 of the 15 lists. Using the 10, equally-intelligible lists, a comparison of speech recognition performance across the two groups suggested similar performance between NH participants at a −3 dB SNR and the CI users at a +10 SNR. Several additional analyses were conducted to support the reliability and validity of the 10 equally intelligible AzBio sentence lists in noise, and preliminary normative data were provided. Conclusions: Ten lists of the commercial version of the AzBio Sentence Test may be used as a reliable and valid measure of speech recognition in noise in listeners with NH or CIs. The equivalent lists may be used for a variety of purposes including audiological evaluations, determination of CI candidacy, hearing aid and CI programming considerations, research, and recommendations for hearing assistive technology. In addition, the preliminary normative data provided in this study establishes a starting point for the creation of comprehensive normative data for the AzBio Sentence Test.


2013 ◽  
Vol 22 (1) ◽  
pp. 53-64 ◽  
Author(s):  
Erin C. Schafer ◽  
Christy Huynh ◽  
Denise Romine ◽  
Rebecca Jimenez

Purpose The goal of this investigation was to determine the potential benefit of using electromagnetically coupled frequency modulation (FM) neck-loop receivers to address common communication difficulties of adults and adolescents with cochlear implants (CIs). Method Fourteen participants with CIs used the neck-loop FM receiver for a trial period and participated in pre- and posttrial sessions consisting of speech-recognition-in-noise measures with and without the FM system and a subjective rating scale. Most participants also recorded their experiences during the FM-system trial period in a journal. Results The results suggested significantly improved speech recognition in noise with the neck-loop FM system before and after the trial period, with no changes in performance between test sessions. On average, the rating scale and journals revealed improvements with the FM system, relative to the CI alone, in noisy environments or situations at a distance from the primary talker or sound source. Conclusion The results of the study suggest that neck-loop FM receivers significantly improved speech recognition in noise and everyday listening challenges of people using the CIs in 2 separate test sessions. Additional research is warranted for other types of neck-loop receivers and CI sound processors.


2004 ◽  
Vol 15 (10) ◽  
pp. 678-691 ◽  
Author(s):  
Erin C. Schafer ◽  
Linda M. Thibodeau

Speech recognition was evaluated for ten adults with normal hearing and eight adults with Nucleus cochlear implants (CIs) at several different signal-to-noise ratios (SNRs) and with three frequency modulated (FM) system arrangements: desktop, body worn, and miniature direct connect. Participants were asked to repeat Hearing in Noise Test (HINT) sentences presented with speech noise in a classroom setting and percent correct word repetition was determined. Performance was evaluated for both normal-hearing and CI participants with the desktop soundfield system. In addition, speech recognition for the CI participants was evaluated using two FM systems electrically coupled to their speech processors. When comparing the desktop sound field and the No-FM condition, only the listeners with normal hearing made significant improvements in speech recognition in noise. When comparing the performance across the three FM conditions for the CI listeners, the two electrically coupled FM systems resulted in significantly greater improvements in speech recognition in noise relative to the desktop soundfield system.


2008 ◽  
Vol 18 (1) ◽  
pp. 19-24
Author(s):  
Erin C. Schafer

Children who use cochlear implants experience significant difficulty hearing speech in the presence of background noise, such as in the classroom. To address these difficulties, audiologists often recommend frequency-modulated (FM) systems for children with cochlear implants. The purpose of this article is to examine current empirical research in the area of FM systems and cochlear implants. Discussion topics will include selecting the optimal type of FM receiver, benefits of binaural FM-system input, importance of DAI receiver-gain settings, and effects of speech-processor programming on speech recognition. FM systems significantly improve the signal-to-noise ratio at the child's ear through the use of three types of FM receivers: mounted speakers, desktop speakers, or direct-audio input (DAI). This discussion will aid audiologists in making evidence-based recommendations for children using cochlear implants and FM systems.