Dosimetric aspects of the therapeutic photon beams from a dual-energy linear accelerator

1988 ◽  
Vol 15 (2) ◽  
pp. 250-257 ◽  
Author(s):  
M. S. A. L. Al-Ghazi ◽  
B. Arjune ◽  
J. A. Fiedler ◽  
P. D. Sharma
1995 ◽  
Vol 20 (1) ◽  
pp. 55-66 ◽  
Author(s):  
Anil K. Sharma ◽  
Sanjay S. Supe ◽  
N. Anantha ◽  
K. Subbarangaiah

2004 ◽  
Vol 31 (7) ◽  
pp. 1980-1986 ◽  
Author(s):  
Fujio Araki ◽  
Nobuyuki Moribe ◽  
Toshiaki Shimonobou ◽  
Yasuyuki Yamashita

Author(s):  
C. Varatharaj ◽  
M. Ravikumar ◽  
Sanjay Supe ◽  
S. Sathiyan ◽  
K. Ganesh ◽  
...  

2017 ◽  
Vol 3 (2) ◽  
pp. 287-290
Author(s):  
Michael Schaks ◽  
Johannes Zähle ◽  
Martin Janich ◽  
Patrick Hübsch ◽  
Nico Homonnay ◽  
...  

AbstractAn Elekta Synergy LINAC was used to investigate the beam quality index Q and the beam quality correction factor kQ, which is used for absolute dosimetry, in off-axis photon fields. It was found that the beam quality index Q of the photon energies with flattening filter decreases with increasing distance to the central axis, at 6 MV by 4.27% and at 15 MV by 3.98% inside a range of 15 cm off-axis. The beam quality index for flattening filter free photon fields also decreases with increasing distance to the central axis. In this case Q changed only by 1.01% inside the above range.


1989 ◽  
Vol 16 (6) ◽  
pp. 896-901 ◽  
Author(s):  
Komanduri Ayyangar ◽  
Inder Daftari ◽  
Jatinder Palta ◽  
Nagalingam Suntharalingam

2018 ◽  
Vol 18 (1) ◽  
pp. 55-62
Author(s):  
Muhammad Isa Khan ◽  
Muhammad Bilal Tahir ◽  
Muhammad Rafique ◽  
Tahir Iqbal ◽  
Sabiha Zulfiqar ◽  
...  

AbstractPurposeThis work reports our study to commission a radiochromic film dosimetry system using the timely EBT3 film. We carried out dosimetric evaluations on different characteristics of photon beams (e.g., flatness, symmetry and penumbra) in radiation dose delivery.Materials and MethodsA Varian linear accelerator producing 6 and 15 MV photon beams with 120 multi-leaf collimator was used in this study. PTW ionisation chamber was used to measure the beam characteristics such as symmetry, flatness and penumbra and these measurements were used to commission the radiochormic EBT3 film dosimetry system. The results of irradiated films were analysed using the radiochromic film QA Pro software 2016.ResultsThe measured film doses were analysed at two different colour channels (green and red) using two scanning geometries (i.e., upper or lower side of film facing the scanner light source) at two dose levels (10 and 40 Gy). The difference between the ionisation chamber and film results was found insignificant and within the acceptable range as per the World Health Organisation standard.ConclusionResults of the comparison between the ionisation chamber and film measurements show that our radiochormic EBT3 film dosimetry system is reliable and cost-effective in the output measurement of a linear accelerator. Our measurements confirm that our EBT3 film dosimetry agreed well with the ionisation chamber, and can be used as a re-validation tool for linear accelerator quality control.


Sign in / Sign up

Export Citation Format

Share Document