Sci-Thur AM: YIS - 07: Optimizing dual-energy x-ray parameters using a single filter for both high and low-energy images to enhance soft-tissue imaging

2016 ◽  
Vol 43 (8Part2) ◽  
pp. 4929-4930
Author(s):  
Wesley Bowman ◽  
Mike Sattarivand
2021 ◽  
Vol 11 (10) ◽  
pp. 4349
Author(s):  
Tianzhong Xiong ◽  
Wenhua Ye ◽  
Xiang Xu

As an important part of pretreatment before recycling, sorting has a great impact on the quality, efficiency, cost and difficulty of recycling. In this paper, dual-energy X-ray transmission (DE-XRT) combined with variable gas-ejection is used to improve the quality and efficiency of in-line automatic sorting of waste non-ferrous metals. A method was proposed to judge the sorting ability, identify the types, and calculate the mass and center-of-gravity coordinates according to the shading of low-energy, the line scan direction coordinate and transparency natural logarithm ratio of low energy to high energy (R_value). The material identification was satisfied by the nearest neighbor algorithm of effective points in the material range to the R_value calibration surface. The flow-process of identification was also presented. Based on the thickness of the calibration surface, the material mass and center-of-gravity coordinates were calculated. The feasibility of controlling material falling points by variable gas-ejection was analyzed. The experimental verification of self-made materials showed that identification accuracy by count basis was 85%, mass and center-of-gravity coordinates calculation errors were both below 5%. The method proposed features high accuracy, high efficiency, and low operation cost and is of great application value even to other solid waste sorting, such as plastics, glass and ceramics.


2004 ◽  
Vol 287 (5) ◽  
pp. E842-E847 ◽  
Author(s):  
Marie-Pierre St-Onge ◽  
ZiMian Wang ◽  
Mary Horlick ◽  
Jack Wang ◽  
Steven B. Heymsfield

Dual-energy X-ray absorptiometry (DEXA) provides a measure of lean soft tissue (LST). LST hydration, often assumed to be constant, is relevant to several aspects of DEXA body composition estimates. The aims of this study were to develop a theoretical model of LST total body water (TBW) content and to examine hydration effects with empirically derived model coefficients and then to experimentally test the model's prediction that, in healthy adults, LST hydration is not constant but varies as a function of extra- and intracellular water distribution (E/I). The initial phase involved TBW/LST model development and application with empirically derived model coefficients. Model predictions were then tested in a cross-sectional study of 215 healthy adults. LST was measured by DEXA, extracellular water (ECW) by NaBr dilution, intracellular water (ICW) by whole body 40K counting, and TBW by 2H2O dilution. TBW estimates, calculated as ECW + ICW, were highly correlated with ( r = 0.97, SEE = 2.1 kg, P < 0.001) and showed no significant bias compared with TBW measured by 2H2O. Model-predicted TBW/LST was almost identical to experimentally derived values (means ± SD) in the total group (0.767 vs. 0.764 ± 0.028). LST hydration was significantly correlated with E/I (total group, r = 0.30, SEE = 0.027, P < 0.001). Although E/I increased with age (men, r = 0.48; women, r = 0.37; both P < 0.001), the association between TBW/LST and age was nonsignificant. Hydration of the DEXA-derived LST compartment is thus not constant but varies predictably with ECW and ICW distribution. This observation has implications for the accuracy of body fat measurements by DEXA and the use of TBW as a means of checking DEXA system calibration.


1997 ◽  
Vol 51 (5) ◽  
pp. 312-317 ◽  
Author(s):  
CD Economos ◽  
ME Nelson ◽  
MA Fiatarone ◽  
GE Dallal ◽  
SB Heymsfield ◽  
...  
Keyword(s):  

2019 ◽  
Vol 67 ◽  
pp. 205
Author(s):  
Matthew Donoghue ◽  
Brendan Tuohy ◽  
Christoph Kleefeld

2005 ◽  
Author(s):  
S. A. Graham ◽  
J. H. Siewerdsen ◽  
D. J. Moseley ◽  
H. Keller ◽  
N. A. Shkumat ◽  
...  