WE-AB-207A-08: BEST IN PHYSICS (IMAGING): Advanced Scatter Correction and Iterative Reconstruction for Improved Cone-Beam CT Imaging On the TrueBeam Radiotherapy Machine

2016 ◽  
Vol 43 (6Part39) ◽  
pp. 3799-3799 ◽  
Author(s):  
A Wang ◽  
P Paysan ◽  
M Brehm ◽  
A Maslowski ◽  
M Lehmann ◽  
...  
2004 ◽  
Vol 31 (5) ◽  
pp. 1195-1202 ◽  
Author(s):  
Ruola Ning ◽  
Xiangyang Tang ◽  
David Conover

2012 ◽  
Vol 103 ◽  
pp. S91
Author(s):  
C.J. Boylan ◽  
T.E. Marchant ◽  
J. Stratford ◽  
J. Rodgers ◽  
J. Malik ◽  
...  

2015 ◽  
Vol 60 (3) ◽  
pp. 1339-1365 ◽  
Author(s):  
Wei Zhao ◽  
Stephen Brunner ◽  
Kai Niu ◽  
Sebastian Schafer ◽  
Kevin Royalty ◽  
...  

2019 ◽  
Vol 27 (5) ◽  
pp. 805-819 ◽  
Author(s):  
Dmitri Matenine ◽  
Matthieu Schmittbuhl ◽  
Stéphane Bedwani ◽  
Philippe Després ◽  
Jacques A. de Guise

2020 ◽  
Vol 62 (11) ◽  
pp. 1511-1514
Author(s):  
Dmitri Matenine ◽  
Marc Kachelriess ◽  
Philippe Després ◽  
Jacques A. de Guise ◽  
Matthieu Schmittbuhl

2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
Xue Dong ◽  
Michael Petrongolo ◽  
Tianye Niu ◽  
Lei Zhu

Excessive imaging dose from repeated scans and poor image quality mainly due to scatter contamination are the two bottlenecks of cone-beam CT (CBCT) imaging. Compressed sensing (CS) reconstruction algorithms show promises in recovering faithful signals from low-dose projection data but do not serve well the needs of accurate CBCT imaging if effective scatter correction is not in place. Scatter can be accurately measured and removed using measurement-based methods. However, these approaches are considered unpractical in the conventional FDK reconstruction, due to the inevitable primary loss for scatter measurement. We combine measurement-based scatter correction and CS-based iterative reconstruction to generate scatter-free images from low-dose projections. We distribute blocked areas on the detector where primary signals are considered redundant in a full scan. Scatter distribution is estimated by interpolating/extrapolating measured scatter samples inside blocked areas. CS-based iterative reconstruction is finally carried out on the undersampled data to obtain scatter-free and low-dose CBCT images. With only 25% of conventional full-scan dose, our method reduces the average CT number error from 250 HU to 24 HU and increases the contrast by a factor of 2.1 on Catphan 600 phantom. On an anthropomorphic head phantom, the average CT number error is reduced from 224 HU to 10 HU in the central uniform area.