SU-E-T-510: Mathematical Analysis of Approximate Biological Effective Dose (BED) Calculation for Multi-Phase Radiotherapy Treatment Plans

2014 ◽  
Vol 41 (6Part19) ◽  
pp. 344-344
Author(s):  
K Kauweloa ◽  
A Gutierrez ◽  
A Bergamo ◽  
S Stathakis ◽  
N Papanikolaou ◽  
...  
2014 ◽  
Vol 2 (2) ◽  
pp. 020226
Author(s):  
Kevin Kauweloa ◽  
Alonso Gutierrez ◽  
Angelo Bergamo ◽  
Sotirios Stathakis ◽  
Niko Papanikolaou ◽  
...  

2014 ◽  
Vol 41 (7) ◽  
pp. 071707 ◽  
Author(s):  
Kevin I. Kauweloa ◽  
Alonso N. Gutierrez ◽  
Angelo Bergamo ◽  
Sotirios Stathakis ◽  
Nikos Papanikolaou ◽  
...  

2018 ◽  
Vol 43 (1) ◽  
pp. 11-22 ◽  
Author(s):  
Kevin I. Kauweloa ◽  
Alonso N. Gutierrez ◽  
Angelo M. Bergamo ◽  
Sotirios Stathakis ◽  
Nikos Papanikolaou ◽  
...  

2004 ◽  
Vol 29 (1) ◽  
pp. 42-48 ◽  
Author(s):  
Ashesh B. Jani ◽  
Christopher M. Hand ◽  
Anthony E. Lujan ◽  
John C. Roeske ◽  
Gregory P. Zagaja ◽  
...  

2014 ◽  
Vol 41 (6Part19) ◽  
pp. 339-339
Author(s):  
K Kauweloa ◽  
A Gutierrez ◽  
A Bergamo ◽  
S Stathakis ◽  
N Papanikolaou ◽  
...  

2016 ◽  
Vol 16 (4) ◽  
pp. 383-390
Author(s):  
Patchareewan Khadsiri ◽  
Ekkasit Tharavichitkul ◽  
Suwit Saekho ◽  
Nisa Chawapun

AbstractPurposeTo develop a software program to convert physical dose distribution into biological effective dose (BED).MethodsThe MATLAB-based BED distribution software program was designed to import the radiotherapy treatment plan from the computer treatment planning system and to convert the physical dose distribution into the BED distribution. The BED calculation was based on the linear-quadratic-linear model (LQ-L model). Besides radiobiological parameters, other specific data could be fed in through the panel. The accuracy of the program was verified by comparing the BED distribution with manual calculation.ResultsThis software program was able to import the radiotherapy treatment plans and pull out pixel-wised physical dose for BED calculation, and display the isoBED lines on the computed tomographic (CT) image. The verification of BED dose distribution was performed in both phantom and clinical cases. It revealed that there were no differences between the program and manual BED calculations.ConclusionIt is feasible and practical to use this in-house BED distribution software program in clinical practices and research work. However, it should be used with caution as the validity of the program depends on the accuracy of the published biological parameters.