TU-C-211-03: Increasing X-Ray Tube Output for Small Focal Spot, Region-Of-Interest Imaging

2011 ◽  
Vol 38 (6Part29) ◽  
pp. 3759-3760
Author(s):  
S Gupta ◽  
D Bednarek ◽  
S Rudin
Author(s):  
D. A. Carpenter ◽  
Ning Gao ◽  
G. J. Havrilla

A monolithic, polycapillary, x-ray optic was adapted to a laboratory-based x-ray microprobe to evaluate the potential of the optic for x-ray micro fluorescence analysis. The polycapillary was capable of collecting x-rays over a 6 degree angle from a point source and focusing them to a spot approximately 40 µm diameter. The high intensities expected from this capillary should be useful for determining and mapping minor to trace elements in materials. Fig. 1 shows a sketch of the capillary with important dimensions.The microprobe had previously been used with straight and with tapered monocapillaries. Alignment of the monocapillaries with the focal spot was accomplished by electromagnetically scanning the focal spot over the beveled anode. With the polycapillary it was also necessary to manually adjust the distance between the focal spot and the polycapillary.The focal distance and focal spot diameter of the polycapillary were determined from a series of edge scans.


2015 ◽  
pp. 50-58
Author(s):  
Thi Dung Nguyen ◽  
Tam Vo

Background: The patients on hemodialysis have a significantly decreased quality of life. One of many problems which reduce the quality of life and increase the mortality in these patients is osteoporosis and osteoporosis associated fractures. Objectives: To assess the bone density of those on hemodialysis by dual energy X ray absorptiometry and to examine the risk factors of bone density reduction in these patients. Patients and Method: This is a cross-sectional study, including 93 patients on chronic hemodialysis at the department of Hemodialysis at Cho Ray Hospital. Results: Mean bone densities at the region of interest (ROI) neck, trochanter, Ward triangle, intertrochanter and total neck are 0.603 ± 0.105; 0.583 ± 0.121; 0.811 ± 0.166; 0.489 ± 0.146; 0.723 ± 0.138 g/cm2 respectively. The prevalences of osteoporosis at those ROI are 39.8%, 15.1%; 28%; 38.7%; and 26.9% respectively. The prevalences of osteopenia at those ROI are 54.8%; 46.3%; 60.2%; 45.2% and 62.7% respectively. The prevalence of osteopososis in at least one ROI is 52.7% and the prevalence of osteopenia in at least one ROI is 47.3%. There are relations between the bone density at the neck and the gender of the patient and the albuminemia. Bone density at the trochanter is influenced by gender, albuminemia, calcemia and phosphoremia. Bone density at the intertrochanter is affected by the gender. Bone density at the Ward triangle is influenced by age and albuminemia. Total neck bone density is influenced by gender, albuminemia and phosphoremia. Conclusion: Osteoporosis in patients on chronic hemodialysis is an issue that requires our attention. There are many interventionable risk factors of bone density decrease in these patients. Key words: Osteoporosis, DEXA, chronic renal failure, chronic hemodialysis


2015 ◽  
Vol 82 ◽  
pp. 138-145 ◽  
Author(s):  
A.D. Oliveira ◽  
M.J. Fartaria ◽  
J. Cardoso ◽  
L.M. Santos ◽  
C. Oliveira ◽  
...  

2009 ◽  
Vol 6 (3) ◽  
pp. 489-494 ◽  
Author(s):  
Danijela Arandjic ◽  
Dusko Kosutic ◽  
Djordje Lazarevic

This paper shows the results of dose assessment for dental radiographic procedures. Entrance surface doses for 5 different procedures were assessed. More than 15 hospitals, twenty X-ray units in total, were encompassed in this research. Patient doses were estimated based on results of X-ray tube output measurements. Finally, doses were compared with Reference levels. Higher dose values were observed for X-ray units with 50 kVp. In comparison with digital units, doses from other procedures are significantly higher. .


1993 ◽  
Vol 49 (8) ◽  
pp. 1246
Author(s):  
Seiichi Mimura ◽  
Noriaki Akagi ◽  
Fumie Kimura ◽  
Shigefumi Kadohisa ◽  
Yasutaka Mikami ◽  
...  

2017 ◽  
Vol 24 (1) ◽  
pp. 103-109 ◽  
Author(s):  
Sergey Terentyev ◽  
Maxim Polikarpov ◽  
Irina Snigireva ◽  
Marco Di Michiel ◽  
Sergey Zholudev ◽  
...  

Linear parabolic diamond refractive lenses are presented, designed to withstand high thermal and radiation loads coming from upgraded accelerator X-ray sources. Lenses were manufactured by picosecond laser treatment of a high-quality single-crystal synthetic diamond. Twelve lenses with radius of curvature at parabola apex R = 200 µm, geometrical aperture A = 900 µm and length L = 1.5 mm were stacked as a compound refractive lens and tested at the ESRF ID06 beamline. A focal spot of size 2.2 µm and a gain of 20 were measured at 8 keV. The lens profile and surface quality were estimated by grating interferometry and X-ray radiography. In addition, the influence of X-ray glitches on the focusing properties of the compound refractive lens were studied.