scholarly journals Estimator for photon counting energy selective x-ray imaging with multibin pulse height analysis

2011 ◽  
Vol 38 (5) ◽  
pp. 2324-2334 ◽  
Author(s):  
Robert E. Alvarez
Author(s):  
M. Lundqvist ◽  
B. Cederstrom ◽  
V. Chmill ◽  
M. Danielsson ◽  
B. Hasegawa

2001 ◽  
Vol 72 (1) ◽  
pp. 717-720 ◽  
Author(s):  
Y. Liang ◽  
K. Ida ◽  
S. Kado ◽  
T. Minami ◽  
S. Okamura ◽  
...  

Sensors ◽  
2016 ◽  
Vol 16 (6) ◽  
pp. 764 ◽  
Author(s):  
Bart Dierickx ◽  
Qiang Yao ◽  
Nick Witvrouwen ◽  
Dirk Uwaerts ◽  
Stijn Vandewiele ◽  
...  

2009 ◽  
Vol 80 (12) ◽  
pp. 126104 ◽  
Author(s):  
Y. P. Zhang ◽  
Yi Liu ◽  
J. W. Yang ◽  
X. Y. Song ◽  
M. Liao ◽  
...  

1965 ◽  
Vol 9 ◽  
pp. 354-364 ◽  
Author(s):  
D. W. Wilbur ◽  
J. W. Gofman

AbstractAn investigation has been made of the relative Kβ intensities in different chemical states of the sulfur atom using the Kα lines, with appropriate corrections, to provide the intensity standards. Both inorganic and organic compounds were included in the study. The data for each compound appear to be reliable to about ± 0.5%, while the whole series of compounds shows a variation greater than 20% in the corrected Kβ/Kα ratios. Energies were also measured, particularly the Kα energies, and their shifts were studied relative to the Kβ, intensity shifts. The work was done with a plane, single-crystal, helium-path spectrometer with proportional counter and pulse-height analysis for detection. The results are indicative of the usefulness of the method both in clarifying an uncertain chemical state and in studying the electronic structure of the bonded atom.


2021 ◽  
Vol 16 (12) ◽  
pp. C12014
Author(s):  
M. Zoladz ◽  
P. Grybos ◽  
R. Szczygiel

Abstract X-ray imaging of moving objects using line detectors remains the most popular method of object content and structure examination with a typical resolution limited to 0.4–1 mm. Higher resolutions are difficult to obtain as, for the detector in the form of a single pixel row, the narrower the detector is, the lower the image Signal to Noise Ratio (SNR). This is because, for smaller pixel sizes, fewer photons hit the pixel in each time unit for a given radiation intensity. To overcome the trade-off between the SNR and spatial resolution, a two-dimensional sensor, namely a pixel matrix can be used. Imaging of moving objects with a pixel matrix requires time-domain integration (TDI). Straightforward TDI implementation is based on the proper accumulation of images acquired during consecutive phases of an object’s movement. Unfortunately, this method is much more demanding regarding data transfer and processing. Data from the whole pixel matrix instead of a single pixel row must be transferred out of the chip and then processed. The alternative approach is on-chip TDI implementation. It takes advantage of photons acquired by multiple rows (a higher SNR), but generates similar data amount as a single pixel row and does not require data processing out of the chip. In this paper, on-chip TDI is described and verified by using a single photon counting two-dimensional (a matrix of 128 × 192 pixels) CdTe hybrid X-ray detector with the 100 µm × 100 µm pixel size with up to four energy thresholds per pixel. Spatial resolution verification is combined with the Material Discrimination X-ray (MDX) imaging method.


2011 ◽  
Vol 59 (5) ◽  
pp. 3114-3119 ◽  
Author(s):  
Yu-Na Choi ◽  
Seung-Wan Lee ◽  
Hyo-Min Cho ◽  
Hyun-Ju Ryu ◽  
Young-Jin Lee ◽  
...  

1960 ◽  
Vol 4 ◽  
pp. 370-381
Author(s):  
Kurt F.J. Heinrich

AbstractPulse-height analysis is a valuable tool in X-ray fluorescence analysis, both for qualitative and quantitative purposes. The elimination of higher order interferences permits determinations that would otherwise be very difficult or impossible, The systematic application of pulse-height analysis in qualitative work greatly simplifies the interpretation of complex spectra. In certain cases one can apply nondispersive analysis, relying on the pulse-height analyzer alone for separating energy levels of X-ray photons. Technique and limitations of pulse-height analysis will be discussed.


Sign in / Sign up

Export Citation Format

Share Document