scholarly journals A design methodology using signal-to-noise ratio for plastic scintillation detectors design and performance optimization

2009 ◽  
Vol 36 (11) ◽  
pp. 5214-5220 ◽  
Author(s):  
Frédéric Lacroix ◽  
A. Sam Beddar ◽  
Mathieu Guillot ◽  
Luc Beaulieu ◽  
Luc Gingras
2020 ◽  
Author(s):  
Sophie Bavard ◽  
Aldo Rustichini ◽  
Stefano Palminteri

Converging evidence suggests that economic values are rescaled as a function of the range of the available options. Critically, although locally adaptive, range adaptation has been shown to lead to suboptimal choices. This is particularly striking in reinforcement learning (RL) situations when options are extrapolated from their original context. Range adaptation can be seen as the result of an adaptive coding process aiming at increasing the signal-to-noise ratio. However, this hypothesis leads to a counterintuitive prediction: decreasing outcome uncertainty should increase range adaptation and, consequently, extrapolation errors. Here, we tested the paradoxical relation between range adaptation and performance in a large sample of subjects performing variants of a RL task, where we manipulated task difficulty. Results confirmed that range adaptation induces systematic extrapolation errors and is stronger when decreasing outcome uncertainty. Finally, we propose a range-adapting model and show that it is able to parsimoniously capture all the observed results.


2020 ◽  
Author(s):  
Sophie Bavard ◽  
Aldo Rustichini ◽  
Stefano Palminteri

AbstractConverging evidence suggests that economic values are rescaled as a function of the range of the available options. Critically, although locally adaptive, range adaptation has been shown to lead to suboptimal choices. This is particularly striking in reinforcement learning (RL) situations when options are extrapolated from their original context. Range adaptation can be seen as the result of an adaptive coding process aiming at increasing the signal-to-noise ratio. However, this hypothesis leads to a counter-intuitive prediction: decreasing outcome uncertainty should increase range adaptation and, consequently, extrapolation errors. Here, we tested the paradoxical relation between range adaptation and performance in a large sample of subjects performing variants of a RL task, where we manipulated task difficulty. Results confirmed that range adaptation induces systematic extrapolation errors and is stronger when decreasing outcome uncertainty. Finally, we propose a range-adapting model and show that it is able to parsimoniously capture all the observed results.


2013 ◽  
Vol 2013 ◽  
pp. 1-11 ◽  
Author(s):  
Xuezhi Zeng ◽  
Andreas Fhager ◽  
Peter Linner ◽  
Mikael Persson ◽  
Herbert Zirath

We design a time domain microwave system dedicated to medical imaging. The measurement accuracy of the system, that is, signal-to-noise ratio, due to voltage noise and timing noise, is evaluated. Particularly, the effect of coupling media on the measurement accuracy is investigated both numerically and experimentally. The results suggest that the use of suitable coupling media betters the measurement accuracy in the frequency range of interest. A signal-to-noise ratio higher than 30 dB is achievable in the range of 500 MHz to 3 GHz when the effective sampling rate is 50 Gsa/s. It is also indicated that the effect of the timing jitter on the strongest received signal is comparable to that of the voltage noise.


2018 ◽  
Vol 30 (1) ◽  
pp. 38-48 ◽  
Author(s):  
Gozde Goncu Berk

Purpose The purpose of this paper is to develop a user friendly, wearable pain management system by optimizing CAD embroidery parameters for manufacturing high performance dry transcutaneous electrical neural stimulation (TENS) electrodes. Design/methodology/approach User-centered design methodology is employed to identify user needs related to TENS devices. Optimization of CAD embroidery parameters was done by measuring and calculating resistance and signal-to-noise values for electrodes manufactured with different conductive thread, stitch pattern, and stitch density types. Findings Characteristics of the conductive thread such as thickness and irregularity, embroidery stitch pattern, stitch density therefore the amount of conductive thread used all effect resistance values and signal-to-noise values of TENS electrodes. Low resistance of TENS electrode surface does not mean high signal-to-noise ratio and high TENS signal quality. Satin stitch type with low stitch density provides the best resistance and signal-to-noise ratio for a TENS electrode. Originality/value This study reported the design process of a wearable pain management system with a focus on optimization of embroidery manufacturing parameters for development of TENS electrodes. The design process not only required technical optimization but also understanding user problems related to use of conventional TENS devices. Proposed end product is a user friendly, electronic textile based, wireless wearable pain management system in different forms suitable for major pain areas such as knee, elbow and neck.


Author(s):  
David A. Grano ◽  
Kenneth H. Downing

The retrieval of high-resolution information from images of biological crystals depends, in part, on the use of the correct photographic emulsion. We have been investigating the information transfer properties of twelve emulsions with a view toward 1) characterizing the emulsions by a few, measurable quantities, and 2) identifying the “best” emulsion of those we have studied for use in any given experimental situation. Because our interests lie in the examination of crystalline specimens, we've chosen to evaluate an emulsion's signal-to-noise ratio (SNR) as a function of spatial frequency and use this as our critereon for determining the best emulsion.The signal-to-noise ratio in frequency space depends on several factors. First, the signal depends on the speed of the emulsion and its modulation transfer function (MTF). By procedures outlined in, MTF's have been found for all the emulsions tested and can be fit by an analytic expression 1/(1+(S/S0)2). Figure 1 shows the experimental data and fitted curve for an emulsion with a better than average MTF. A single parameter, the spatial frequency at which the transfer falls to 50% (S0), characterizes this curve.


Sign in / Sign up

Export Citation Format

Share Document