TH-D-210A-05: Characterization of the Spatial and Energy Distribution of Electrons Emitted From a Gold Nanoparticle Irradiated by X-Rays Using Monte Carlo Simulations

2009 ◽  
Vol 36 (6Part28) ◽  
pp. 2819-2819 ◽  
Author(s):  
M Leung ◽  
J Chow ◽  
D Chithrani ◽  
M Lee ◽  
B Oms ◽  
...  
2021 ◽  
Author(s):  
Eric Da Silva

A hydroxyaptite [HAp; Ca5(PO4)3OH] phantom material was developed with the goal of improving the calibration protocol of the 125I-induced in vivo X-ray fluorescence (IVXRF) system of bone strontium quantification with further application to other IVXRF bone metal quantification systems, particulary those associated with bone lead quantification. It was found that calcium can be prepared pure of inherent contamination from strontium (and other elements) through a hydroxide precipitation producing pure Ca(OH)2, thereby, allowing for the production of a blank phantom which has not been available previously. The pure Ca(OH)2 can then be used for the preparation of pure CaHPO4 ⋅ 2H2O. A solid state pure HAp phantom can then be prepared by reaction of Ca(OH)2 and CaHPO4 ⋅ 2H2O mixed as to produce a Ca/P mole ratio of 1.67, that in HAp and the mineral phase of bone, in the presence of a setting solution prepared as to raise the total phosphate concentration of the solution by increasing the solubility CaHPO4 ⋅ 2H2O and thereby precipitating HAp. The procedure can only be used to prepare phantoms in which doping with the analyte does not disturb the Ca/P ratio substantially. In cases in which phantoms are to be prepared with high concentrations of strontium, the cement mixture can be modified as to introduce strontium in the form of Sr(OH)2 ⋅ 8H2O as to maintain a (Ca + Sr)/P ratio of 1.67. It was found by both X-ray diffraction spectrometry and Raman spectroscopy studies that strontium substitutes for calcium as in bone when preparing phantoms by this route. The necessity for the blank bone phantoms was assessed through the first blank bone phantom measurement and Monte Carlo simulations. It was found that for the 125I-induced IVXRF system of bone strontium quantification, the source, 125I brachytherapy seeds may be contributing coherently and incoherently scattered zirconium X-rays to the measured spectra, thereby requiring the use of the blank bone phantom as a means of improving the overall quantification methodology. Monte Carlo simulations were employed to evaluate any improvement by the introduction of HAp phantoms into the coherent normalization-based calibration procedure. It was found that HAp phantoms remove the need for a coherent conversion factor (CCF) thereby potentially increasing accuracy of the quantification. Further, it was found that in order for soft tissue attenuation corrections to be possible using spectroscopic information alone, HAp along with a suitable soft tissue surrogate material need to be employed. The HAp phantom material was used for the evaluations of portable X-ray analyzer systems for their potential for IVXRF quantification of lead and strontium with a focus on a comparison between tungsten, silver and rhodium target systems. Silver and rhodium target X-ray tube systems were found to be comparable for this quantification.


2006 ◽  
Vol 33 (6Part2) ◽  
pp. 1990-1990
Author(s):  
I Sechopoulos ◽  
S Suryanarayanan ◽  
S Vedantham ◽  
A Karellas

2019 ◽  
Vol 204 ◽  
pp. 11004 ◽  
Author(s):  
V. Mikhaylov ◽  
A. Kugler ◽  
V. Kushpil ◽  
O. Svoboda ◽  
P. Tlustý ◽  
...  

The Projectile Spectator Detector (PSD) of the CBM experiment at the future FAIR facility is a compensating lead-scintillator calorimeter designed to measure the energy distribution of the forward going projectile nucleons and nuclei fragments (reaction spectators) produced close to the beam rapidity. The detector performance for the centrality and reaction plane determination is reviewed based on Monte-Carlo simulations of gold-gold collisions by means of four different heavy-ion event generators. The PSD energy resolution and the linearity of the response measured at CERN PS for the PSD supermodule consisting of 9 modules are presented. Predictions of the calorimeter radiation conditions at CBM and response measurement of one PSD module equipped with neutron irradiated MPPCs used for the light read out are discussed.


2011 ◽  
Vol 41 (8) ◽  
pp. 1484-1497 ◽  
Author(s):  
Nobuhito Mori ◽  
Miguel Onorato ◽  
Peter A. E. M. Janssen

Abstract Based on Monte Carlo simulations of the nonlinear Schrödinger equation in two horizontal dimensions, the dependence of the kurtosis on the directional energy distribution of the initial conditions is examined. The parametric survey is carried out to obtain the behavior of the kurtosis as function of the Benjamin–Feir index and directional spread in directional sea states. As directional dispersion effect becomes significant, the kurtosis monotonically decreases in comparison with the unidirectional waves. A parameterization of the kurtosis estimated from directional spectra is proposed here; the error of the parameterization is at most 10%. The parameterization is verified against laboratory data, and good agreement is obtained.


2012 ◽  
Vol 70 (7) ◽  
pp. 1388-1391 ◽  
Author(s):  
Lucio P. Neves ◽  
Eric A.B. Silva ◽  
Ana P. Perini ◽  
Nora L. Maidana ◽  
Linda V.E. Caldas

2009 ◽  
Vol 36 (6Part8) ◽  
pp. 2512-2512 ◽  
Author(s):  
J Chow ◽  
M Leung ◽  
D Chithrani ◽  
M Lee ◽  
B Oms ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document