Description Of A 3D Reconstruction Algorithm For Diverging X-Ray Beams

Author(s):  
Pierre Grangeat
2013 ◽  
Vol 32 (2) ◽  
pp. 107 ◽  
Author(s):  
Luc Gillibert ◽  
Dominique Jeulin

X-ray microtomography from solid propellant allows studying the microstructure of fragmented grains in damaged samples. A new reconstruction algorithm of fragmented grains for 3D images is introduced. Based on a watershed transform of a morphological closing of the input image, the algorithm can be used  with different sets of markers. Two of them are compared. After the grain reconstruction, a multiscale segmentation  algorithm is used to extract each fragment of the damaged grains. This allows an original quantitative study of the  fragmentation of each grain in 3D. Experimental results on X-ray microtomographic images of a solid propellant fragmented under compression are presented and validated.


1997 ◽  
Vol 503 ◽  
Author(s):  
B. L. Evans ◽  
J. B. Martin ◽  
L. W. Burggraf

ABSTRACTThe viability of a Compton scattering tomography system for nondestructively inspecting thin, low Z samples for corrosion is examined. This technique differs from conventional x-ray backscatter NDI because it does not rely on narrow collimation of source and detectors to examine small volumes in the sample. Instead, photons of a single energy are backscattered from the sample and their scattered energy spectra are measured at multiple detector locations, and these spectra are then used to reconstruct an image of the object. This multiplexed Compton scatter tomography technique interrogates multiple volume elements simultaneously. Thin samples less than 1 cm thick and made of low Z materials are best imaged with gamma rays at or below 100 keV energy. At this energy, Compton line broadening becomes an important resolution limitation. An analytical model has been developed to simulate the signals collected in a demonstration system consisting of an array of planar high-purity germanium detectors. A technique for deconvolving the effects of Compton broadening and detector energy resolution from signals with additive noise is also presented. A filtered backprojection image reconstruction algorithm with similarities to that used in conventional transmission computed tomography is developed. A simulation of a 360–degree inspection gives distortion-free results. In a simulation of a single-sided inspection, a 5 mm × 5 mm corrosion flaw with 50% density is readily identified in 1-cm thick aluminum phantom when the signal to noise ratio in the data exceeds 28.


2016 ◽  
Vol 24 (13) ◽  
pp. 14564 ◽  
Author(s):  
Michael T. McCann ◽  
Masih Nilchian ◽  
Marco Stampanoni ◽  
Michael Unser

2006 ◽  
Author(s):  
Nong Sang ◽  
Weixue Peng ◽  
Heng Li ◽  
Zhen Zhang ◽  
Tianxu Zhang
Keyword(s):  

2010 ◽  
Vol 37 (7Part1) ◽  
pp. 3773-3781 ◽  
Author(s):  
Yang Lu ◽  
Hengyong Yu ◽  
Guohua Cao ◽  
Jun Zhao ◽  
Ge Wang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document