Optical Analysis Software As An Application For Three-Dimensional Display

1984 ◽  
Author(s):  
Michael F. Abernathy
Author(s):  
Honglei Xu ◽  
Linhuan Wang

In order to improve the accuracy of dynamic detection of wind field in the three-dimensional display space, system software is carried out on the actual scene and corresponding airborne radar observation information data, and the particle swarm algorithm fuzzy logic algorithm is introduced into the wind field dynamic simulation process in three-dimensional display space, to analyze the error of the filtering result in detail, to process the hurricane Lily Doppler radar measurement data with the optimal adaptive filtering according to the error data. The three-dimensional wind field synchronous measurement data obtained by filtering was compared with three-dimensional wind field synchronous measurement data of the GPS dropsonde in this experiment, the sea surface wind field measurement data of the multi-band microwave radiometer, and the wind field data at aircraft altitude.


Animals ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 1242
Author(s):  
Georg Haider ◽  
Ursula Schulz ◽  
Nikola Katic ◽  
Christian Peham ◽  
Gilles Dupré

Single-port access systems (SPASs) are currently used in human and veterinary surgeries. However, they pose technical challenges, such as instrument crowding, intra- and extracorporeal instrument collision, and reduced maneuverability. Studies comparing the maneuverability of the scopes and instruments in different SPASs are lacking. This study aimed to compare the maneuverability of three different SPASs: the Covidien SILS-port, Storz Endocone, and glove port. A clear acrylic box with artificial skin placed at the bottom was used to mimic the abdominal wall and cavity. The three SPASs were placed from below, and a 10-mm endoscope and 5-mm instrument were introduced. A motion analysis system consisting of 18 cameras and motion analysis software were used to track the movement of the endoscope and instrument, to determine the volume of the cone-shaped, three-dimensional figures over which movement was possible, with higher values indicating greater maneuverability. The Mann–Whitney U test was used for the analysis. The maneuverability of the endoscope alone was significantly higher in the glove port system than in the other two SPASs. When inserting an additional instrument, the maneuverability significantly decreased in the SILS-port and Endocone, but not in the glove port. The highest maneuverability overall was found in the glove port.


2020 ◽  
Vol 461 ◽  
pp. 125260 ◽  
Author(s):  
Peng Sun ◽  
Chenning Tao ◽  
Jinlei Zhang ◽  
Rengmao Wu ◽  
Siqi Liu ◽  
...  

2021 ◽  
Vol 52 (S1) ◽  
pp. 613-616
Author(s):  
Gewei Yan ◽  
Jiayi Li ◽  
Chenxi Zhao ◽  
Zengxiang Lu ◽  
Zhaojun Liu

2020 ◽  
Vol 132 (22) ◽  
pp. 8494-8498 ◽  
Author(s):  
Shigang Wan ◽  
Hongqi Zhou ◽  
Jinxiong Lin ◽  
Wei Lu

2008 ◽  
Author(s):  
William J. Dallas ◽  
Hans Roehrig ◽  
Daniel J. Allen

1991 ◽  
Vol 3 (2) ◽  
pp. 194-199 ◽  
Author(s):  
Hiroshi HASHIMOTO ◽  
Satoshi YOKOYAMA ◽  
Kyoko NAKAO ◽  
Kousuke HARUKI ◽  
Motoko CHIBA ◽  
...  

2014 ◽  
Vol 940 ◽  
pp. 433-436 ◽  
Author(s):  
Ying Zhang ◽  
Xin Shi

Based on the detailed analysis of the STL file format, VC++ 6.0 programming language was used to extract the STL ASCII and binary file information, at the same time, using the OpenGL triangle drawing technology for graphical representation of the STL file, with rendering functions such as material, coordinate transformation, lighting, et al, finally realizing the loading and three-dimensional display of STL ASCII and binary file formats.


Sign in / Sign up

Export Citation Format

Share Document