Improved total variation based CT reconstruction algorithm with noise estimation

2012 ◽  
Author(s):  
Xin Jin ◽  
Liang Li ◽  
Le Shen ◽  
Zhiqiang Chen
2021 ◽  
Vol 1920 (1) ◽  
pp. 012036
Author(s):  
Hongyan Shi ◽  
Aidi Wu ◽  
Shidi Yang ◽  
Dongjiang Ji

Recent applications of conventional iterative coordinate descent (ICD) algorithms to multislice helical CT reconstructions have shown that conventional ICD can greatly improve image quality by increasing resolution as well as reducing noise and some artifacts. However, high computational cost and long reconstruction times remain as a barrier to the use of conventional algorithm in the practical applications. Among the various iterative methods that have been studied for conventional, ICD has been found to have relatively low overall computational requirements due to its fast convergence. This paper presents a fast model-based iterative reconstruction algorithm using spatially nonhomogeneous ICD (NH-ICD) optimization. The NH-ICD algorithm speeds up convergence by focusing computation where it is most needed. The NH-ICD algorithm has a mechanism that adaptively selects voxels for update. First, a voxel selection criterion VSC determines the voxels in greatest need of update. Then a voxel selection algorithm VSA selects the order of successive voxel updates based upon the need for repeated updates of some locations, while retaining characteristics for global convergence. In order to speed up each voxel update, we also propose a fast 3-D optimization algorithm that uses a quadratic substitute function to upper bound the local 3-D objective function, so that a closed form solution can be obtained rather than using a computationally expensive line search algorithm. The experimental results show that the proposed method accelerates the reconstructions by roughly a factor of three on average for typical 3-D multislice geometries.


2021 ◽  
pp. 1-19
Author(s):  
Wei Wang ◽  
Xiang-Gen Xia ◽  
Chuanjiang He ◽  
Zemin Ren ◽  
Jian Lu

In this paper, we present an arc based fan-beam computed tomography (CT) reconstruction algorithm by applying Katsevich’s helical CT image reconstruction formula to 2D fan-beam CT scanning data. Specifically, we propose a new weighting function to deal with the redundant data. Our weighting function ϖ ( x _ , λ ) is an average of two characteristic functions, where each characteristic function indicates whether the projection data of the scanning angle contributes to the intensity of the pixel x _ . In fact, for every pixel x _ , our method uses the projection data of two scanning angle intervals to reconstruct its intensity, where one interval contains the starting angle and another contains the end angle. Each interval corresponds to a characteristic function. By extending the fan-beam algorithm to the circle cone-beam geometry, we also obtain a new circle cone-beam CT reconstruction algorithm. To verify the effectiveness of our method, the simulated experiments are performed for 2D fan-beam geometry with straight line detectors and 3D circle cone-beam geometry with flat-plan detectors, where the simulated sinograms are generated by the open-source software “ASTRA toolbox.” We compare our method with the other existing algorithms. Our experimental results show that our new method yields the lowest root-mean-square-error (RMSE) and the highest structural-similarity (SSIM) for both reconstructed 2D and 3D fan-beam CT images.


2019 ◽  
Vol 30 (5) ◽  
pp. 055404
Author(s):  
Zhaoyan Qu ◽  
Xiaojie Zhao ◽  
Jinxiao Pan ◽  
Ping Chen