Impact of Cn<sup>2</sup> profile on tomographic reconstruction performance: application to E-ELT wide field AO systems

Author(s):  
A. Costille ◽  
T. Fusco
Author(s):  
jinwoo kim ◽  
Dongho Lee ◽  
Guentae Doh ◽  
Sanghoo Park ◽  
Holak Kim ◽  
...  

Abstract A diagnostic system was developed for spectrally resolved, three-dimensional tomographic reconstruction of Hall thruster plasmas, and local intensity profiles of Xe I and Xe II emissions were reconstructed. In this diagnostic system, 28 virtual cameras were generated using a single, fixed charge-coupled device (CCD) camera by rotating the Hall thruster to form a sufficient number of lines of sight. The Phillips-Tikhonov regularization algorithm was used to reconstruct local emission profiles from the line-integrated emission signals. The reconstruction performance was evaluated using both azimuthally symmetric and asymmetric synthetic phantom images including 5% Gaussian white noise, which resulted in a root-mean-square error of the reconstruction within an order of 10-3 even for a 1% difference in the azimuthal intensity distribution. Using the developed system, three-dimensional local profiles of Xe II emission (541.9 nm) from radiative decay of the excited state 5p4(3P2)6p2[3]˚5/2 and Xe I emission (881.9 nm) from 5p5(2P˚3/2)6p2[5/2]3 were obtained, and two different shapes were found depending on the wavelength and the distance from the thruster exit plane. In particular, a stretched central jet structure was distinctively observed in the Xe II emission profile beyond 10 mm from the thruster exit, while gradual broadening was found in the Xe I emission. Approximately 10% azimuthal nonuniformities were observed in the local Xe I and Xe II intensity profiles in the near-plume region (< 10 mm), which could not be quantitatively distinguished by analysis of the frontal photographic image. Three-dimensional Xe I and Xe II intensity profiles were also obtained in the plume region, and the differences in the structures of both emissions were visually confirmed.


2013 ◽  
Vol 31 (1) ◽  
pp. 101 ◽  
Author(s):  
C. Correia ◽  
K. Jackson ◽  
J.-P. Véran ◽  
D. Andersen ◽  
O. Lardière ◽  
...  

2016 ◽  
Author(s):  
Henri Der Sarkissian ◽  
Jeanpierre Guédon ◽  
Benoit Recur ◽  
Nicolas Normand

2008 ◽  
Vol 14 (4) ◽  
pp. 296-305 ◽  
Author(s):  
Baptiste Gault ◽  
Frederic de Geuser ◽  
Leigh T. Stephenson ◽  
Michael P. Moody ◽  
Barrington C. Muddle ◽  
...  

The application of wide field-of-view detection systems to atom probe experiments emphasizes the importance of careful parameter selection in the tomographic reconstruction of the analyzed volume, as the sensitivity to errors rises steeply with increases in analysis dimensions. In this article, a self-consistent method is presented for the systematic determination of the main reconstruction parameters. In the proposed approach, the compression factor and the field factor are determined using geometrical projections from the desorption images. A three-dimensional Fourier transform is then applied to a series of reconstructions, and after comparing to the known material crystallography, the efficiency of the detector is estimated. The final results demonstrate a significant improvement in the accuracy of the reconstructed volumes.


Author(s):  
M. G. Lagally

It has been recognized since the earliest days of crystal growth that kinetic processes of all Kinds control the nature of the growth. As the technology of crystal growth has become ever more refined, with the advent of such atomistic processes as molecular beam epitaxy, chemical vapor deposition, sputter deposition, and plasma enhanced techniques for the creation of “crystals” as little as one or a few atomic layers thick, multilayer structures, and novel materials combinations, the need to understand the mechanisms controlling the growth process is becoming more critical. Unfortunately, available techniques have not lent themselves well to obtaining a truly microscopic picture of such processes. Because of its atomic resolution on the one hand, and the achievable wide field of view on the other (of the order of micrometers) scanning tunneling microscopy (STM) gives us this opportunity. In this talk, we briefly review the types of growth kinetics measurements that can be made using STM. The use of STM for studies of kinetics is one of the more recent applications of what is itself still a very young field.


Author(s):  
Neil Rowlands ◽  
Jeff Price ◽  
Michael Kersker ◽  
Seichi Suzuki ◽  
Steve Young ◽  
...  

Three-dimensional (3D) microstructure visualization on the electron microscope requires that the sample be tilted to different positions to collect a series of projections. This tilting should be performed rapidly for on-line stereo viewing and precisely for off-line tomographic reconstruction. Usually a projection series is collected using mechanical stage tilt alone. The stereo pairs must be viewed off-line and the 60 to 120 tomographic projections must be aligned with fiduciary markers or digital correlation methods. The delay in viewing stereo pairs and the alignment problems in tomographic reconstruction could be eliminated or improved by tilting the beam if such tilt could be accomplished without image translation.A microscope capable of beam tilt with simultaneous image shift to eliminate tilt-induced translation has been investigated for 3D imaging of thick (1 μm) biologic specimens. By tilting the beam above and through the specimen and bringing it back below the specimen, a brightfield image with a projection angle corresponding to the beam tilt angle can be recorded (Fig. 1a).


Author(s):  
J. Frank ◽  
B. F. McEwen ◽  
M. Radermacher ◽  
C. L. Rieder

The tomographic reconstruction from multiple projections of cellular components, within a thick section, offers a way of visualizing and quantifying their three-dimensional (3D) structure. However, asymmetric objects require as many views from the widest tilt range as possible; otherwise the reconstruction may be uninterpretable. Even if not for geometric obstructions, the increasing pathway of electrons, as the tilt angle is increased, poses the ultimate upper limitation to the projection range. With the maximum tilt angle being fixed, the only way to improve the faithfulness of the reconstruction is by changing the mode of the tilting from single-axis to conical; a point within the object projected with a tilt angle of 60° and a full 360° azimuthal range is then reconstructed as a slightly elliptic (axis ratio 1.2 : 1) sphere.


Author(s):  
C.L. Woodcock

Despite the potential of the technique, electron tomography has yet to be widely used by biologists. This is in part related to the rather daunting list of equipment and expertise that are required. Thanks to continuing advances in theory and instrumentation, tomography is now more feasible for the non-specialist. One barrier that has essentially disappeared is the expense of computational resources. In view of this progress, it is time to give more attention to practical issues that need to be considered when embarking on a tomographic project. The following recommendations and comments are derived from experience gained during two long-term collaborative projects.Tomographic reconstruction results in a three dimensional description of an individual EM specimen, most commonly a section, and is therefore applicable to problems in which ultrastructural details within the thickness of the specimen are obscured in single micrographs. Information that can be recovered using tomography includes the 3D shape of particles, and the arrangement and dispostion of overlapping fibrous and membranous structures.


2013 ◽  
Vol 183 (8) ◽  
pp. 888-894
Author(s):  
G.M. Beskin ◽  
S.V. Karpov ◽  
V.L. Plokhotnichenko ◽  
S.F. Bondar ◽  
A.V. Perkov ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document