Application of color digital holographic microscopy for analysis of stained tissue sections

Author(s):  
Xiaoli Mo ◽  
Björn Kemper ◽  
Patrik Langehanenberg ◽  
Angelika Vollmer ◽  
Jinghui Xie ◽  
...  
2013 ◽  
Author(s):  
Dominik Bettenworth ◽  
Philipp Lenz ◽  
Philipp Krausewitz ◽  
Markus Brückner ◽  
Steffi Ketelhut ◽  
...  

2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Arne Bokemeyer ◽  
Phil Robin Tepasse ◽  
Lena Quill ◽  
Philipp Lenz ◽  
Emile Rijcken ◽  
...  

AbstractIntestinal strictures are a frequent complication in patients with Crohn’s Disease (CD) and the presence of fibrosis within strictures impacts the therapeutic treatment approach. Here, we evaluate quantitative phase imaging (QPI) using digital holographic microscopy (DHM) for the evaluation of fibrosis within CD strictures. 30 full thickness resection specimens were obtained from non-stenotic and stenotic tissue areas of 15 CD patients. Cryostat sections were analyzed by DHM to measure the spatial distribution of the refractive index (RI) to quantify tissue density. Complementary, histopathological evaluation of H&E staining and immunofluorescence (IF) targeting fibrosis markers served as the gold standard. Moreover, tissue stiffness was evaluated by elastography. RI values assessed by DHM were significantly higher in stenotic compared to non-stenotic tissue areas (p < 0.001). Histopathological analysis using H&E staining and IF confirmed the elevated expression of fibrosis markers in stenotic compared to non-stenotic tissue (all p < 0.001). The RI retrieved by DHM strongly correlated with the amount of fibrosis as determined by IF (p < 0.001; R2 = 0.48). Furthermore, elastography detected a significantly higher tissue stiffness in stenotic as compared to non-stenotic tissue sections (p < 0.001). In conclusion, QPI using DHM accurately assesses fibrotic properties of CD-associated strictures and may improve the characterization of CD strictures.


Author(s):  
Xiaoli Mo ◽  
Björn Kemper ◽  
Patrik Langehanenberg ◽  
Angelika Vollmer ◽  
Jinghui Xie ◽  
...  

2021 ◽  
Vol 84 ◽  
pp. 200-207
Author(s):  
Jiansen Pan ◽  
Qingmei Peng ◽  
Guoliang Zhang ◽  
Qingyi Xie ◽  
Xiangjun Gong ◽  
...  

Photonics ◽  
2021 ◽  
Vol 8 (7) ◽  
pp. 276
Author(s):  
Yun Liu ◽  
Peihua Bu ◽  
Mingxing Jiao ◽  
Junhong Xing ◽  
Ke Kou ◽  
...  

The coherent noise always exists in digital holographic microscopy due to the laser source, degrading the image quality. A method of speckle suppression using the dynamic speckle illumination, produced by double-moving diffusers, is presented in digital holographic microscopy. The space–time correlation functions are theoretically analyzed from the statistics distribution in the doubly and singly scattered system, respectively. The configuration of double-moving diffusers is demonstrated to have better performance in speckle suppression compared with the single diffuser and moving-static double diffusers cases. The experiment results verify the feasibility of the approach. The presented approach only requires a single shot interferogram to realize the speckle reduction, accordingly it has the potential application in real-time measurement.


Sign in / Sign up

Export Citation Format

Share Document