A new non-uniformity response correction method of x-ray real time imaging system

2009 ◽  
Author(s):  
Min Yang ◽  
Hao Chen ◽  
Jun-Jiang Li ◽  
Yuan Wang ◽  
Cheng-xin Zhang
2012 ◽  
Vol 452-453 ◽  
pp. 1513-1517
Author(s):  
Ai Guo Wang ◽  
Dong Lin Yang ◽  
Peng Zhao

x-ray real time imaging detection technology is a kind of important way for industrial nondestructive test. On the basis of basic theory on X-ray detection, The influence factors on x-ray real time imaging detection precision is analyzed in this article. Through analysis for the focus of X-ray source and the unintelligibility of geometric image, the relation between the optimal amplification multiple and the imaging quality is presented and the electric collimator to solve the influence on imaging quality from the scattered ray. The experimental result shows that the detection resolution ratio is up to 50PL/cm and the sensitivity is up to 1.4 % to solve the on-line real time detection for pore, inclusion and looseness and verify the application feasibility in the detection of cast aluminum parts for x-ray real time imaging detection technology.


2011 ◽  
Vol 18 (4) ◽  
pp. 569-574 ◽  
Author(s):  
Masato Hoshino ◽  
Kentaro Uesugi ◽  
James Pearson ◽  
Takashi Sonobe ◽  
Mikiyasu Shirai ◽  
...  

An X-ray stereo imaging system with synchrotron radiation was developed at BL20B2, SPring-8. A portion of a wide X-ray beam was Bragg-reflected by a silicon crystal to produce an X-ray beam which intersects with the direct X-ray beam. Samples were placed at the intersection point of the two beam paths. X-ray stereo images were recorded simultaneously by a detector with a large field of view placed close to the sample. A three-dimensional wire-frame model of a sample was created from the depth information that was obtained from the lateral positions in the stereo image. X-ray stereo angiography of a mouse femoral region was performed as a demonstration of real-time stereo imaging. Three-dimensional arrangements of the femur and blood vessels were obtained.


1975 ◽  
Author(s):  
A. E. Stewart

This paper discusses the development of a real-time high energy x-ray imaging system for use in dynamic fluoroscopy of aero gas turbines. In order to cover the range of subjects on gas turbines, over ten combinations of film and screen types are used. Three different types of x-ray imaging systems were considered for use: direct type intensifiers (cesium iodide phosphors), and indirect type intensifiers — Marconi “Marionette” and the Oude Delft “Delcalix.”


Author(s):  
Yuzhao Li ◽  
Qingwei Ji ◽  
Wenqiang Shi ◽  
Jiahui Hong ◽  
Simin Cheng ◽  
...  

Electronics ◽  
2019 ◽  
Vol 8 (9) ◽  
pp. 944 ◽  
Author(s):  
Heesin Lee ◽  
Joonwhoan Lee

X-ray scattering significantly limits image quality. Conventional strategies for scatter reduction based on physical equipment or measurements inevitably increase the dose to improve the image quality. In addition, scatter reduction based on a computational algorithm could take a large amount of time. We propose a deep learning-based scatter correction method, which adopts a convolutional neural network (CNN) for restoration of degraded images. Because it is hard to obtain real data from an X-ray imaging system for training the network, Monte Carlo (MC) simulation was performed to generate the training data. For simulating X-ray images of a human chest, a cone beam CT (CBCT) was designed and modeled as an example. Then, pairs of simulated images, which correspond to scattered and scatter-free images, respectively, were obtained from the model with different doses. The scatter components, calculated by taking the differences of the pairs, were used as targets to train the weight parameters of the CNN. Compared with the MC-based iterative method, the proposed one shows better results in projected images, with as much as 58.5% reduction in root-mean-square error (RMSE), and 18.1% and 3.4% increases in peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM), on average, respectively.


Sign in / Sign up

Export Citation Format

Share Document