Use Of Optical Methods In Stress Analysis Of Three-Dimensional Cracked Body Problems

1982 ◽  
Vol 21 (4) ◽  
Author(s):  
C. W. Smith
Geosciences ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 296
Author(s):  
Richard H. Groshong

This paper is a personal account of the origin and development of the twinned-calcite strain gauge, its experimental verification, and its relationship to stress analysis. The method allows the calculation of the three-dimensional deviatoric strain tensor based on five or more twin sets. A minimum of about 25 twin sets should provide a reasonably accurate result for the magnitude and orientation of the strain tensor. The opposite-signed strain axis orientation is the most accurately located. Where one strain axis is appreciably different from the other two, that axis is generally within about 10° of the correct value. Experiments confirm a magnitude accuracy of 1% strain over the range of 1–12% axial shortening and that samples with more than 40% negative expected values imply multiple or rotational deformations. If two deformations are at a high angle to one another, the strain calculated from the positive and negative expected values separately provides a good estimate of both deformations. Most stress analysis techniques do not provide useful magnitudes, although most provide a good estimate of the principal strain axis directions. Stress analysis based on the number of twin sets per grain provides a better than order-of-magnitude approximation to the differential stress magnitude in a constant strain rate experiment.


2011 ◽  
Vol 301-303 ◽  
pp. 1316-1321 ◽  
Author(s):  
Arthur E. Ruggles ◽  
Bi Yao Zhang ◽  
Spero M. Peters

Positron Emission Tomography (PET) produces a three dimensional spatial distribution of positron-electron annihilations within an image volume. Various positron emitters are available for use in aqueous, organic and liquid metal flows. Preliminary experiments at the University of Tennessee at Knoxville (UTK) injected small flows of PET tracer into a bulk water flow in a four rod bundle. The trajectory and diffusion of the tracer in the bulk flow were then mapped using a PET scanner. A spatial resolution of 1.4 mm is achieved with current preclinical Micro-PET imaging equipment resulting in 200 MB 3D activity fields. A time resolved 3-D spatial activity profile was also measured. The PET imaging method is especially well suited to complex geometries where traditional optical methods such as LDV and PIV are difficult to apply. PET methods are uniquely useful for imaging in opaque fluids, opaque pressure boundaries, and multiphase studies. Several commercial and shareware Computational Fluid Dynamics (CFD) codes are currently used for science and engineering analysis and design. These codes produce detailed three dimensional flow predictions. The models produced by these codes are often difficult to validate. The development of this experimental technique offers a modality for the comparison of CFD outcomes with experimental data. Developed data sets from PET can be used in verification and validation exercises of simulation outcomes.


1994 ◽  
Vol 27 (6) ◽  
pp. 826
Author(s):  
A.J. van den Bogert ◽  
B.M. Nigg

Sign in / Sign up

Export Citation Format

Share Document