Web-based computer-aided-diagnosis (CAD) system for bone age assessment (BAA) of children

Author(s):  
Aifeng Zhang ◽  
Joshua Uyeda ◽  
Sinchai Tsao ◽  
Kevin Ma ◽  
Linda A. Vachon ◽  
...  
Author(s):  
Shaowei Li ◽  
Bowen Liu ◽  
Shulian Li ◽  
Xinyu Zhu ◽  
Yang Yan ◽  
...  

AbstractBone age assessment using hand-wrist X-ray images is fundamental when diagnosing growth disorders of a child or providing a more patient-specific treatment. However, as clinical procedures are a subjective assessment, the accuracy depends highly on the doctor’s experience. Motivated by this, a deep learning-based computer-aided diagnosis method was proposed for performing bone age assessment. Inspired by clinical approaches and aimed to reduce expensive manual annotations, informative regions localization based on a complete unsupervised learning method was firstly performed and an image-processing pipeline was proposed. Subsequently, an image model with pre-trained weights as a backbone was utilized to enhance the reliability of prediction. The prediction head was implemented by a Multiple Layer Perceptron with one hidden layer. In compliance with clinical studies, gender information was an additional input to the prediction head by embedded into the feature vector calculated from the backbone model. After the experimental comparison study, the best results showed a mean absolute error of 6.2 months on the public RSNA dataset and 5.1 months on the additional dataset using MobileNetV3 as the backbone.


2019 ◽  
Vol 43 (1) ◽  
pp. 39-45 ◽  
Author(s):  
Christian Booz ◽  
Julian L. Wichmann ◽  
Sabine Boettger ◽  
Ahmed Al Kamali ◽  
Simon S. Martin ◽  
...  

Diagnostics ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 973
Author(s):  
Valentina Giannini ◽  
Simone Mazzetti ◽  
Giovanni Cappello ◽  
Valeria Maria Doronzio ◽  
Lorenzo Vassallo ◽  
...  

Recently, Computer Aided Diagnosis (CAD) systems have been proposed to help radiologists in detecting and characterizing Prostate Cancer (PCa). However, few studies evaluated the performances of these systems in a clinical setting, especially when used by non-experienced readers. The main aim of this study is to assess the diagnostic performance of non-experienced readers when reporting assisted by the likelihood map generated by a CAD system, and to compare the results with the unassisted interpretation. Three resident radiologists were asked to review multiparametric-MRI of patients with and without PCa, both unassisted and assisted by a CAD system. In both reading sessions, residents recorded all positive cases, and sensitivity, specificity, negative and positive predictive values were computed and compared. The dataset comprised 90 patients (45 with at least one clinically significant biopsy-confirmed PCa). Sensitivity significantly increased in the CAD assisted mode for patients with at least one clinically significant lesion (GS > 6) (68.7% vs. 78.1%, p = 0.018). Overall specificity was not statistically different between unassisted and assisted sessions (94.8% vs. 89.6, p = 0.072). The use of the CAD system significantly increases the per-patient sensitivity of inexperienced readers in the detection of clinically significant PCa, without negatively affecting specificity, while significantly reducing overall reporting time.


Diagnostics ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 694
Author(s):  
Xuejiao Pang ◽  
Zijian Zhao ◽  
Ying Weng

At present, the application of artificial intelligence (AI) based on deep learning in the medical field has become more extensive and suitable for clinical practice compared with traditional machine learning. The application of traditional machine learning approaches to clinical practice is very challenging because medical data are usually uncharacteristic. However, deep learning methods with self-learning abilities can effectively make use of excellent computing abilities to learn intricate and abstract features. Thus, they are promising for the classification and detection of lesions through gastrointestinal endoscopy using a computer-aided diagnosis (CAD) system based on deep learning. This study aimed to address the research development of a CAD system based on deep learning in order to assist doctors in classifying and detecting lesions in the stomach, intestines, and esophagus. It also summarized the limitations of the current methods and finally presented a prospect for future research.


2001 ◽  
Vol 1230 ◽  
pp. 1303-1304
Author(s):  
Fei Cao ◽  
H.K. Huang ◽  
Ewa. Pietka ◽  
Vicente Gilsanz

2019 ◽  
Vol 8 (4) ◽  
pp. 12261-12273

Background: Gastrointestinal (GI) tract abnormalities are most common across the world, and it is a significant threat to the health of human beings. Capsule endoscopy is a non-sedative, non-invasive and patient-friendly procedure for the diagnosis of GI tract abnormalities. However, it is very time consuming and tiresome task for physicians due to length of endoscopy videos. Thus computer-aided diagnosis (CAD) system is a must. Methods: This systematic review aims to investigate state-of-the-art CAD systems for automatic abnormality detection in capsule endoscopy by examining publications from scientific databases namely IEEE Xplore, Science Direct, Springer, and Scopus. Results: Based on defined search criteria and applied inclusion and exclusion criteria, 44 articles are included out of 187. This study presents the current status and analysis of CAD systems for capsule endoscopy. Conclusion: Publicly available larger dataset and a deep learning based CAD system may help to improve the efficiency of automated abnormality detection in capsule endoscopy.


2021 ◽  
Vol 8 ◽  
Author(s):  
Qingling Li ◽  
Yanhua Zhu ◽  
Minglin Chen ◽  
Ruomi Guo ◽  
Qingyong Hu ◽  
...  

Background: It is often difficult to diagnose pituitary microadenoma (PM) by MRI alone, due to its relatively small size, variable anatomical structure, complex clinical symptoms, and signs among individuals. We develop and validate a deep learning -based system to diagnose PM from MRI.Methods: A total of 11,935 infertility participants were initially recruited for this project. After applying the exclusion criteria, 1,520 participants (556 PM patients and 964 controls subjects) were included for further stratified into 3 non-overlapping cohorts. The data used for the training set were derived from a retrospective study, and in the validation dataset, prospective temporal and geographical validation set were adopted. A total of 780 participants were used for training, 195 participants for testing, and 545 participants were used to validate the diagnosis performance. The PM-computer-aided diagnosis (PM-CAD) system consists of two parts: pituitary region detection and PM diagnosis. The diagnosis performance of the PM-CAD system was measured using the receiver operating characteristics (ROC) curve and area under the ROC curve (AUC), calibration curve, accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and F1-score.Results: Pituitary microadenoma-computer-aided diagnosis system showed 94.36% diagnostic accuracy and 98.13% AUC score in the testing dataset. We confirm the robustness and generalization of our PM-CAD system, the diagnostic accuracy in the internal dataset was 96.50% and in the external dataset was 92.26 and 92.36%, the AUC was 95.5, 94.7, and 93.7%, respectively. In human-computer competition, the diagnosis performance of our PM-CAD system was comparable to radiologists with >10 years of professional expertise (diagnosis accuracy of 94.0% vs. 95.0%, AUC of 95.6% vs. 95.0%). For the misdiagnosis cases from radiologists, our system showed a 100% accurate diagnosis. A browser-based software was designed to assist the PM diagnosis.Conclusions: This is the first report showing that the PM-CAD system is a viable tool for detecting PM. Our results suggest that the PM-CAD system is applicable to radiology departments, especially in primary health care institutions.


Sign in / Sign up

Export Citation Format

Share Document