Two-photon bioimaging with a multi-kilowatt peak-power optical pulse source using a 1-μm wavelength mode-locked semiconductor laser

2008 ◽  
Author(s):  
Hengchang Guo ◽  
Keijiro Takashima ◽  
Aya Sato ◽  
Hiroyuki Yokoyama ◽  
Masahito Mure ◽  
...  
2007 ◽  
Vol 32 (18) ◽  
pp. 2726 ◽  
Author(s):  
Masaru Kuramoto ◽  
Nobuyoshi Kitajima ◽  
Hengchang Guo ◽  
Yuji Furushima ◽  
Masao Ikeda ◽  
...  

2007 ◽  
Vol 12 (5) ◽  
pp. 054019 ◽  
Author(s):  
Hiroyuki Yokoyama ◽  
Hiroshi Tsubokawa ◽  
Hengchang Guo ◽  
Jun-ichi Shikata ◽  
Ki-ichi Sato ◽  
...  

2016 ◽  
Vol 41 (17) ◽  
pp. 4028 ◽  
Author(s):  
Yi-Cheng Fang ◽  
Tomohiro Chaki ◽  
Jui-Hung Hung ◽  
Hirohito Yamada ◽  
Hiroyuki Yokoyama

Bioimaging ◽  
1995 ◽  
Vol 3 (2) ◽  
pp. 70-75 ◽  
Author(s):  
Pekka E Hänninen ◽  
Martin Schrader ◽  
Erkki Soini ◽  
Stefan W Hell

2021 ◽  
Vol 390 ◽  
pp. 127102
Author(s):  
Huilong Liu ◽  
Zonghua Hu ◽  
Zhenhua Du ◽  
Jing Xia ◽  
Aga He ◽  
...  

2020 ◽  
Author(s):  
Zhen Zhong ◽  
Xuping Zhang

In the coherent PHI-OTDR system, the phase signal is retrieved based on the reference point and the observation point which are off and closer to the two sides of step of the phase change. In the experiment, the optical pulse with the changed peak power, width or shape is injected into the fiber for interrogating the change of the quantitative characteristic of the measured phase signal. When the pulse width is fixed at 200 ns and its peak power is adjusted from 14 dBm to -23 dBm, the amplitude is slightly increased from 17.3575 rad to 17.4411 rad as long as the Rayleigh backscattering signal can be found in the electrical signal. Changing the pulse width from 260 ns to 80 ns when the peak power is fixed at 14 dBm, the maximum amplitude and the minimum amplitude of the measured phase signal are 17.4625 rad to 17.4509 rad, respectively. When the arbitrary shape of the optical pulse generated from the MZI structure with a changed delay fiber from 3 m to 6 m, the amplitude varies from 17.4558 rad to 17.4819 rad. For every measurement, the change of frequency is also small. And the small value of standard deviation supports the accuracy of the measurement. All the measurements show that the changed pulse nearly has no impact on the quantitative characteristic of the measured phase signal in the coherent PHI-OTDR system. Moreover, we also find that the phase signal of external event can be correctly extracted as long as the Rayleigh backscattering signal can be detected.<br>


Sign in / Sign up

Export Citation Format

Share Document