On spatial resolution of quasi-optical focal plane antenna array imagers

2004 ◽  
Author(s):  
Leonid V. Volkov ◽  
Alexander I. Voronko ◽  
Natalie L. Volkova
2001 ◽  
Vol 7 (S2) ◽  
pp. 148-149
Author(s):  
C.D. Poweleit ◽  
J Menéndez

Oil immersion lenses have been used in optical microscopy for a long time. The light’s wavelength is decreased by the oil’s index of refraction n and this reduces the minimum spot size. Additionally, the oil medium allows a larger collection angle, thereby increasing the numerical aperture. The SIL is based on the same principle, but offers more flexibility because the higher index material is solid. in particular, SILs can be deployed in cryogenic environments. Using a hemispherical glass the spatial resolution is improved by a factor n with respect to the resolution obtained with the microscope’s objective lens alone. The improvement factor is equal to n2 for truncated spheres.As shown in Fig. 1, the hemisphere SIL is in contact with the sample and does not affect the position of the focal plane. The focused rays from the objective strike the lens at normal incidence, so that no refraction takes place.


2021 ◽  
Vol 9 (6) ◽  
pp. 479-498
Author(s):  
Konstantin Boltar ◽  
Igor Burlakov ◽  
Natalya Iakovleva ◽  
Alekcey Polessky ◽  
Peter Kuznetsov ◽  
...  

In this paper, we report on the design, the fabrication, and performance of SWIR photomodules using sensitive two-dimensional arrays based on InGaAs-heterostructures. The de- sign of suggested InGaAs-heterostructure includes InAlAs wideband barrier layer and high sensitive absorber InGaAs layer which are increasing the uniformity and operability of focal plane array (FPA), so the number of defect elements are less than 0.5 %. The possibilities of spectral range expanding into short-wavelength to 0.5 μm and into long-wavelength to 2.2 μm regions have been considered. The operation principals of active-pulse system for 0.9–1.7 μm spectral range based on InGaAs 320256 FPA with 30 μm pitch have been presented. The investigations showed that the infrared gated-viewing system based on the InGaAs 320256 FPA provided a spatial resolution of 0,6 m.


2021 ◽  
Vol 20 ◽  
pp. 1-6
Author(s):  
Yumi Takizawa ◽  
Cahya Edi Santosa ◽  
Atsushi Fukasawa ◽  
Josaphat Tetuko Sri Sumantyo

This paper presents a circular polarization plane antenna using linearly truncated triplate stripline resonator antenna. Glass-epoxy substrate is used in place of Teflon substrate for low cost fabrication. In spite the electrical dimension differs only √2 (root two), the dimensions of circular disk, its truncation, and feeding lines must be chosen precisely and accurately to get better characteristics of gain 12 dB compared to 10 dB by elliptic resonator with 4-antenna array.


2011 ◽  
Author(s):  
F. Pozas-Flores ◽  
R. Carmona-Galán ◽  
J. Fernández-Berni ◽  
Á. Rodríguez-Vázquez

2018 ◽  
Vol 619 ◽  
pp. A9 ◽  
Author(s):  
H. M. Schmid ◽  
A. Bazzon ◽  
R. Roelfsema ◽  
D. Mouillet ◽  
J. Milli ◽  
...  

Context. The SPHERE “planet finder” is an extreme adaptive optics (AO) instrument for high resolution and high contrast observations at the Very Large Telescope (VLT). We describe the Zurich Imaging Polarimeter (ZIMPOL), the visual focal plane subsystem of SPHERE, which pushes the limits of current AO systems to shorter wavelengths, higher spatial resolution, and much improved polarimetric performance. Aims. We present a detailed characterization of SPHERE/ZIMPOL which should be useful for an optimal planning of observations and for improving the data reduction and calibration. We aim to provide new benchmarks for the performance of high contrast instruments, in particular for polarimetric differential imaging. Methods. We have analyzed SPHERE/ZIMPOL point spread functions (PSFs) and measure the normalized peak surface brightness, the encircled energy, and the full width half maximum (FWHM) for different wavelengths, atmospheric conditions, star brightness, and instrument modes. Coronagraphic images are described and the peak flux attenuation and the off-axis flux transmission are determined. Simultaneous images of the coronagraphic focal plane and the pupil plane are analyzed and the suppression of the diffraction rings by the pupil stop is investigated. We compared the performance at small separation for different coronagraphs with tests for the binary α Hyi with a separation of 92 mas and a contrast of Δm ≈ 6m. For the polarimetric mode we made the instrument calibrations using zero polarization and high polarization standard stars and here we give a recipe for the absolute calibration of polarimetric data. The data show small (< 1 mas) but disturbing differential polarimetric beam shifts, which can be explained as Goos-Hähnchen shifts from the inclined mirrors, and we discuss how to correct this effect. The polarimetric sensitivity is investigated with non-coronagraphic and deep, coronagraphic observations of the dust scattering around the symbiotic Mira variable R Aqr. Results. SPHERE/ZIMPOL reaches routinely an angular resolution (FWHM) of 22−28 mas, and a normalized peak surface brightness of SB0 − mstar ≈ −6.5m arcsec−2 for the V-, R- and I-band. The AO performance is worse for mediocre ≳1.0″ seeing conditions, faint stars mR ≳ 9m, or in the presence of the “low wind” effect (telescope seeing). The coronagraphs are effective in attenuating the PSF peak by factors of > 100, and the suppression of the diffracted light improves the contrast performance by a factor of approximately two in the separation range 0.06″−0.20″. The polarimetric sensitivity is Δp < 0.01% and the polarization zero point can be calibrated to better than Δp ≈ 0.1%. The contrast limits for differential polarimetric imaging for the 400 s I-band data of R Aqr at a separation of ρ = 0.86″ are for the surface brightness contrast SBpol( ρ)−mstar ≈ 8m arcsec−2 and for the point source contrast mpol( ρ)−mstar ≈ 15m and much lower limits are achievable with deeper observations. Conclusions. SPHERE/ZIMPOL achieves imaging performances in the visual range with unprecedented characteristics, in particular very high spatial resolution and very high polarimetric contrast. This instrument opens up many new research opportunities for the detailed investigation of circumstellar dust, in scattered and therefore polarized light, for the investigation of faint companions, and for the mapping of circumstellar Hα emission.


Sign in / Sign up

Export Citation Format

Share Document