Automated determination of regions of interest for 3D-vision-based quality control of free-form surfaces

2003 ◽  
Author(s):  
Alex Lallement ◽  
Pierre Graebling ◽  
Ernest Hirsch
2012 ◽  
Vol 50 (4) ◽  
pp. 1045-1061 ◽  
Author(s):  
P. Gilles ◽  
J. Senatore ◽  
S. Segonds ◽  
F. Monies ◽  
W. Rubio

1984 ◽  
Vol 23 (06) ◽  
pp. 277-282 ◽  
Author(s):  
A. Van Lingen ◽  
G. Westera ◽  
M. van ◽  
W. Den Hollander ◽  
E. E. Van der Wall ◽  
...  

SummaryThis paper presents an alternative method of demarcating regions of in terest over the myocardium after ad ministration of 123I-heptadecanoic acid to patients with coronary artery disea se. In a matrix of 32 × 32 pixels the elimination rates of the radioactivity, which are not corrected for back ground activity, are visualized per pixel in a functional image. The func tional image showed areas in the myocardium with high values of uncorrected elimination rates. These areas corresponded with the tracer defects on the scintigram. Corrected elimination rates obtained from re gions of interest of functional images were comparable with those of scinti grams. Thus based on functional im ages of uncorrected elimination rates a reliable, objective determination of regions of interest over normal and abnormal myocardium can be made.


Author(s):  
P.F. Collins ◽  
W.W. Lawrence ◽  
J.F. Williams

AbstractA procedure for the automated determination of ammonia in tobacco has been developed. Ammonia is extracted from the ground tobacco sample with water and is determined with a Technicon Auto Analyser system which employs separation of the ammonia through volatilization followed by colourimetry using the phenate-hypochlorite reaction. The procedure has been applied to a variety of tobaccos containing from 0.02 to 0.5 % ammonia with an overall relative standard deviation of 2 %. The accuracy of the procedure as judged by recovery tests and by comparison to a manual distillation method is considered adequate


2019 ◽  
Author(s):  
Chem Int

Recent study was conducted to develop a simple UV spectrophotometric method to determine Phenytoin in bulk and injection form according to official requirement and validate as per ICH guidelines. λmax of Phenytoin was found 202 nm. Linearity existed perceived in the concentration assortment 2-8 μg/ml (r2 = 0.999) for the method. The method was validated pertaining to linearity, precision and accuracy studies, LOD and LOQ consistent with ICH guidelines. The existent method was establish to be simple, linear, precise, accurate as well as sensitive and can be applied for routine quality control enquiry for the analysis of Phenytoin in bulk and injection form.


Sign in / Sign up

Export Citation Format

Share Document