Design and performance evaluation of a near-infrared Fourier transform spectrometer

2000 ◽  
Author(s):  
Vidi A. Saptari ◽  
Kamal Youcef-Toumi
1993 ◽  
Vol 48 (5-6) ◽  
pp. 737-738 ◽  
Author(s):  
M. Krüger ◽  
H. Harder ◽  
C. Gerke ◽  
H. Dreizler

Abstract The design and performance of an automatic scan wave-guide microwave Fourier transform spectrometer is described, which is of great help in assigning microwave spectra.


The Analyst ◽  
2018 ◽  
Vol 143 (19) ◽  
pp. 4699-4706 ◽  
Author(s):  
Kaiyuan Zheng ◽  
Chuantao Zheng ◽  
Zidi Liu ◽  
Qixin He ◽  
Qiaoling Du ◽  
...  

The majority of broadband cavity-enhanced systems are used to detect trace gas species in the visible spectral range.


2019 ◽  
Vol 12 (11) ◽  
pp. 6125-6141 ◽  
Author(s):  
Minqiang Zhou ◽  
Bavo Langerock ◽  
Mahesh Kumar Sha ◽  
Nicolas Kumps ◽  
Christian Hermans ◽  
...  

Abstract. The Total Carbon Column Observing Network (TCCON) column-averaged dry air mole fraction of CH4 (XCH4) measurements have been widely used to validate satellite observations and to estimate model simulations. The GGG2014 code is the standard TCCON retrieval software used in performing a profile scaling retrieval. In order to obtain several vertical pieces of information in addition to the total column, in this study, the SFIT4 retrieval code is applied to retrieve the CH4 mole fraction vertical profile from the Fourier transform spectrometer (FTS) spectrum at six sites (Ny-Ålesund, Sodankylä, Bialystok, Bremen, Orléans and St Denis) during the time period of 2016–2017. The retrieval strategy of the CH4 profile retrieval from ground-based FTS near-infrared (NIR) spectra using the SFIT4 code (SFIT4NIR) is investigated. The degree of freedom for signal (DOFS) of the SFIT4NIR retrieval is about 2.4, with two distinct pieces of information in the troposphere and in the stratosphere. The averaging kernel and error budget of the SFIT4NIR retrieval are presented. The data accuracy and precision of the SFIT4NIR retrievals, including the total column and two partial columns (in the troposphere and stratosphere), are estimated by TCCON standard retrievals, ground-based in situ measurements, Atmospheric Chemistry Experiment – Fourier Transform Spectrometer (ACE-FTS) satellite observations, TCCON proxy data and AirCore and aircraft measurements. By comparison against TCCON standard retrievals, it is found that the retrieval uncertainty of SFIT4NIR XCH4 is similar to that of TCCON standard retrievals with systematic uncertainty within 0.35 % and random uncertainty of about 0.5 %. The tropospheric and stratospheric XCH4 from SFIT4NIR retrievals are assessed by comparison with AirCore and aircraft measurements, and there is a 1.0 ± 0.3 % overestimation in the SFIT4NIR tropospheric XCH4 and a 4.0 ± 2.0 % underestimation in the SFIT4NIR stratospheric XCH4, which are within the systematic uncertainties of SFIT4NIR-retrieved partial columns in the troposphere and stratosphere respectively.


2014 ◽  
Vol 10 (3) ◽  
pp. 172-175 ◽  
Author(s):  
Yu-xin Qin ◽  
Jing-qiu Liang ◽  
Zhong-zhu Liang ◽  
Chao Tian ◽  
Jin-guang Lü ◽  
...  

1995 ◽  
Vol 149 ◽  
pp. 316-327 ◽  
Author(s):  
J.P. Maillard

AbstractWith the advent of bidimensional array detectors the throughput advantage of a Fourier Transform Spectrometer (FTS) can be used to create a new type of 3-D spectrometer. The classical multiplex property in the spectral domain of a FTS is multiplied by the number of pixel of the array. The points of the entrance field are all observed in parallel. After discussing the properties of this instrument, the coupling of the FTS of the CFH Telescope to a camera equipped with a NICMOS 3 array is described. With this combination, spectro-imaging in any bandpass between 1 and 2.5 µm is possible within a circular 24” field of view, with a scale of 0.33”/pixel, at seeing-limited spatial resolution. Any spectral resolution is choosable up to 30,000. Illustrations are given by a study of the dark side of Venus at 1.27 µm and of planetary nebulae at 2 µm. Many other objects can benefit from this observing mode in the near infrared. Further developments of this 3-D technique are discussed.


1987 ◽  
Vol 20 (1) ◽  
pp. 54-60 ◽  
Author(s):  
A P Thorne ◽  
C J Harris ◽  
I Wynne-Jones ◽  
R C M Learner ◽  
G Cox