Relationship between current load and temperature for quasi-steady state and transient conditions

Author(s):  
Bernard R. Lyon, Jr. ◽  
Gary L. Orlove ◽  
Donna L. Peters
1998 ◽  
Vol 120 (4) ◽  
pp. 652-659 ◽  
Author(s):  
Zhen-Bing Hou ◽  
R. Komanduri

The thermal model developed in Part I of this three-part series is applied in this paper to magnetic float polishing (MFP) of ceramic (Si3N4) balls. Using this method, the flash temperatures, flash times, and temperature distribution at the interface between the balls and the shaft of the MFP apparatus are calculated. Examination of the polished surfaces (scratch lengths) of the balls showed that the length of most scratches during the final stage of polishing is <20 μm and most are formed under transient conditions. But because of the small area of contact and low load encountered in MFP, the results of the calculations under these conditions were found to be very close to the quasi-steady-state conditions. However, it is not possible to know a priori if the conditions are transient or quasi-steady state unless solutions are available for each case. The use of the general solution developed in Part I enables this determination. The minimum flash temperatures and minimum flash times that occur during polishing ensure the determination if adequate temperatures are generated for chemo-mechanical polishing to take place. Of course, the lengths of the scratches would be much longer and the corresponding flash duration longer during the semifinishing operation than during flnishing. The combined temperature and flash duration would determine the extent of chemo-mechanical action under these conditions. The flash temperatures and flash times required for chemo-mechanical action can be used as a basis for the optimization of polishing conditions in MFP.


2008 ◽  
Vol 45 ◽  
pp. 161-176 ◽  
Author(s):  
Eduardo D. Sontag

This paper discusses a theoretical method for the “reverse engineering” of networks based solely on steady-state (and quasi-steady-state) data.


10.2514/3.895 ◽  
1997 ◽  
Vol 11 ◽  
pp. 306-309 ◽  
Author(s):  
Edwin H. Olmstead ◽  
Edward S. Taylor ◽  
Meng Wang ◽  
Parviz Moin ◽  
Scott K. Thomas ◽  
...  

1996 ◽  
Vol 27 (4) ◽  
pp. 247-254 ◽  
Author(s):  
Zekâi Şen

A simple, approximate but practical graphical method is proposed for estimating the storage coefficient independently from the transmissivity value, provided that quasi-steady state flow data are available from a pumping test. In the past, quasi-steady state flow distance-drawdown data have been used for the determination of transmissivity only. The method is applicable to confined and leaky aquifers. The application of the method has been performed for various aquifer test data available in the groundwater literature. The results are within the practical limits of approximation compared with the unsteady state flow solutions.