Research on the Influence of slope and heat release rate on the critical velocity of straddle monorail tunnel

2021 ◽  
Author(s):  
Jiehang Deng ◽  
Yanqiu Chen ◽  
Peng Wang
2013 ◽  
Vol 831 ◽  
pp. 455-459
Author(s):  
Shu Hui Xu ◽  
Ling Fei Cui ◽  
Lei Ning ◽  
Zi Ye Wang

Critical velocity is a very important parameter in smoke control of tunnel fires and the variation of critical velocity against fire heat release rate is also one of the most important issues in tunnel fire researches. In this paper, a simplified physical model of a tunnel was established and the predictions of critical velocity for fire sizes in the 5-100MW range were carried out by FDS simulations. The FDS-predicted dimensionless critical velocities were compared with the values calculated by Wu and Bakar’s model. The result indicated that when the heat release rate was relatively small, Q≤30MW, the critical velocity increased with the increasing of heat release rate and varied as the one-third power of the heat release rate; when Q≥40MW, the growth rate of critical velocity became very small; after Q reach to 60MW, the critical velocity was almost unchanged with the increasing of heat release rate. In addition, the values of critical velocity calculated by Wu and Bakar’model which was derived from small-scale gas fire tests were underestimated. Therefore, the model suggested by Wu and Bakar is not suitable for critical velocity prediction in tunnel fires.


2017 ◽  
Vol 2017 ◽  
pp. 1-12 ◽  
Author(s):  
Ruben Mouangue ◽  
Philippe M. Onguene ◽  
Justin T. Zaida ◽  
Henri P. F. Ekobena

When a fire occurs in a tunnel in the absence of sufficient air supply, large quantities of smoke are generated, filling the vehicles and any space available around them. Hot gases and smoke produced by fire form layers flowing towards extremities of the tunnel which may interfere with person’s evacuation and firefighter’s intervention. This paper carries out a numerical simulation of an unexpected fire occurring in a one-way tunnel in order to investigate for the critical velocity of the ventilation airflow; this one is defined as the minimum velocity able to maintain the combustion products in the downstream side of tunnel. The computation is performed successively with two types of fuels representing a large and a small heat release rate, owing to an open source CFD code called ISIS, which is specific to fires in confined and nonconfined environments. It is indicated that, after several computations of full-scale fires of 43.103 and 19.103 kJ/kg as heat release rate, the velocities satisfying the criterion of healthy environment in the upstream side of the tunnel are 1.34 m/s and 1.12 m/s, respectively.


2019 ◽  
Vol 29 (7) ◽  
pp. 1017-1027
Author(s):  
Guanfeng Yan ◽  
Mingnian Wang ◽  
Li Yu ◽  
Yuan Tian

Nowadays, the critical velocity and back-layering length are the key parameters in longitudinal ventilation design. However, most studies research them at standard air pressure but ambient pressure decreases at high-altitude area and the reduced ambient pressure could affect the smoke movement characteristics in a tunnel fire. In order to investigate the effect of ambient pressure on the velocity and back-layering length in longitudinal ventilated tunnel, theoretical analysis was carried out first and a series of numerical simulation were conducted with varying heat release rate and ambient pressure. Results show that Li’s model is also reliable under various ambient pressures. The critical velocity under various ambient pressures would become larger with an increase in the heat release rate and would remain stable after the heat release rate reaches a certain value. At smaller heat release rate, the length of counterflow would be higher under reduced ambient pressure while it remains the same when the HRR is large. This could provide reference for tunnel ventilation design at high-altitude areas.


2008 ◽  
Vol 18 (2) ◽  
pp. 111-124 ◽  
Author(s):  
C. Chen ◽  
L. Qu ◽  
Y. X. Yang ◽  
G. Q. Kang ◽  
W. K. Chow

2021 ◽  
Vol 11 (7) ◽  
pp. 3247
Author(s):  
Dong Hwan Kim ◽  
Chi Young Lee ◽  
Chang Bo Oh

In this study, the effects of discharge area and atomizing gas type in a twin-fluid atomizer on heptane pool fire-extinguishing performance were investigated under the heat release rate conditions of 1.17 and 5.23 kW in an enclosed chamber. Large and small full cone twin-fluid atomizers were prepared. Nitrogen and air were used as atomizing gases. With respect to the droplet size of water mist, as the water and air flow rates decreased and increased, respectively, the Sauter mean diameter (SMD) of the water mist decreased. The SMD of large and small atomizers were in the range of approximately 12–60 and 12–49 μm, respectively. With respect to the discharge area effect, the small atomizer exhibited a shorter extinguishing time, lower peak surface temperature, and higher minimum oxygen concentration than the large atomizer. Furthermore, it was observed that the effect of the discharge area on fire-extinguishing performance is dominant under certain flow rate conditions. With respect to the atomizing gas type effect, nitrogen and air appeared to exhibit nearly similar extinguishing times, peak surface temperatures, and minimum oxygen concentrations under most flow rate conditions. Based on the present and previous studies, it was revealed that the effect of atomizing gas type on fire-extinguishing performance is dependent on the relative positions of the discharged flow and fire source.


Fuel ◽  
2021 ◽  
Vol 288 ◽  
pp. 119656
Author(s):  
Robbert Willems ◽  
Frank Willems ◽  
Niels Deen ◽  
Bart Somers

Sign in / Sign up