Detection, identification, and quantification of SF6 point-source emissions using Telops hyper-cam LW airborne platform

Author(s):  
Benjamin Saute ◽  
Jean-Philippe Gagnon ◽  
Marc Duval ◽  
Jacob Thibodeau ◽  
Mathieu Gagnon ◽  
...  
Author(s):  
R. E. Heffelfinger ◽  
C. W. Melton ◽  
D. L. Kiefer ◽  
W. M. Henry ◽  
R. J. Thompson

A methodology has been developed and demonstrated which is capable of determining total amounts of asbestos fibers and fibrils in air ranging from as low as fractional nanograms per cubic meter (ng/m3) of air to several micrograms/m3. The method involves the collection of samples on an absolute filter and provides an unequivocal identification and quantification of the total asbestos contents including fibrils in the collected samples.The developed method depends on the trituration under controlled conditions to reduce the fibers to fibrils, separation of the asbestos fibrils from other collected air particulates (beneficiation), and the use of transmission microscopy for identification and quantification. Its validity has been tested by comparative analyses by neutron activation techniques. It can supply the data needed to set emissions criteria and to serve as a basis for assessing the potential hazard for asbestos pollution to the populace.


Author(s):  
D. A. Carpenter ◽  
Ning Gao ◽  
G. J. Havrilla

A monolithic, polycapillary, x-ray optic was adapted to a laboratory-based x-ray microprobe to evaluate the potential of the optic for x-ray micro fluorescence analysis. The polycapillary was capable of collecting x-rays over a 6 degree angle from a point source and focusing them to a spot approximately 40 µm diameter. The high intensities expected from this capillary should be useful for determining and mapping minor to trace elements in materials. Fig. 1 shows a sketch of the capillary with important dimensions.The microprobe had previously been used with straight and with tapered monocapillaries. Alignment of the monocapillaries with the focal spot was accomplished by electromagnetically scanning the focal spot over the beveled anode. With the polycapillary it was also necessary to manually adjust the distance between the focal spot and the polycapillary.The focal distance and focal spot diameter of the polycapillary were determined from a series of edge scans.


Planta Medica ◽  
2011 ◽  
Vol 77 (12) ◽  
Author(s):  
A Karioti ◽  
J Kukic Markovic ◽  
S Petrovic ◽  
M Niketic ◽  
A Bilia

Sign in / Sign up

Export Citation Format

Share Document