Ultrathin transmission-type bent crystals for XFEL spectral diagnostic

Author(s):  
Liu Xing ◽  
Peng Liu ◽  
Xiaowei Yang ◽  
Shengzhen Yi ◽  
Tsu-Chien Weng
2010 ◽  
Vol 10 (10) ◽  
pp. 4625-4641 ◽  
Author(s):  
N. L. Ng ◽  
M. R. Canagaratna ◽  
Q. Zhang ◽  
J. L. Jimenez ◽  
J. Tian ◽  
...  

Abstract. In this study we compile and present results from the factor analysis of 43 Aerosol Mass Spectrometer (AMS) datasets (27 of the datasets are reanalyzed in this work). The components from all sites, when taken together, provide a holistic overview of Northern Hemisphere organic aerosol (OA) and its evolution in the atmosphere. At most sites, the OA can be separated into oxygenated OA (OOA), hydrocarbon-like OA (HOA), and sometimes other components such as biomass burning OA (BBOA). We focus on the OOA components in this work. In many analyses, the OOA can be further deconvolved into low-volatility OOA (LV-OOA) and semi-volatile OOA (SV-OOA). Differences in the mass spectra of these components are characterized in terms of the two main ions m/z 44 (CO2+) and m/z 43 (mostly C2H3O+), which are used to develop a new mass spectral diagnostic for following the aging of OA components in the atmosphere. The LV-OOA component spectra have higher f44 (ratio of m/z 44 to total signal in the component mass spectrum) and lower f43 (ratio of m/z 43 to total signal in the component mass spectrum) than SV-OOA. A wide range of f44 and O:C ratios are observed for both LV-OOA (0.17±0.04, 0.73±0.14) and SV-OOA (0.07±0.04, 0.35±0.14) components, reflecting the fact that there is a continuum of OOA properties in ambient aerosol. The OOA components (OOA, LV-OOA, and SV-OOA) from all sites cluster within a well-defined triangular region in the f44 vs. f43 space, which can be used as a standardized means for comparing and characterizing any OOA components (laboratory or ambient) observed with the AMS. Examination of the OOA components in this triangular space indicates that OOA component spectra become increasingly similar to each other and to fulvic acid and HULIS sample spectra as f44 (a surrogate for O:C and an indicator of photochemical aging) increases. This indicates that ambient OA converges towards highly aged LV-OOA with atmospheric oxidation. The common features of the transformation between SV-OOA and LV-OOA at multiple sites potentially enable a simplified description of the oxidation of OA in the atmosphere. Comparison of laboratory SOA data with ambient OOA indicates that laboratory SOA are more similar to SV-OOA and rarely become as oxidized as ambient LV-OOA, likely due to the higher loadings employed in the experiments and/or limited oxidant exposure in most chamber experiments.


2012 ◽  
Vol 357 ◽  
pp. 012026 ◽  
Author(s):  
N F Shul'ga ◽  
V V Syshchenko ◽  
A I Tarnovsky
Keyword(s):  

2011 ◽  
Author(s):  
V. Guidi ◽  
N. Barrière ◽  
V. Bellucci ◽  
R. Camattari ◽  
I. Neri

2001 ◽  
Vol 19 (2) ◽  
pp. 285-293 ◽  
Author(s):  
T.A. PIKUZ ◽  
A. YA. FAENOV ◽  
M. FRAENKEL ◽  
A. ZIGLER ◽  
F. FLORA ◽  
...  

The shadow monochromatic backlighting (SMB) scheme, a modification of the well-known soft X-ray monochromatic backlighting scheme, is proposed. It is based on a spherical crystal as the dispersive element and extends the traditional scheme by allowing one to work with a wide range of Bragg angles and thus in a wide spectral range. The advantages of the new scheme are demonstrated experimentally and supported numerically by ray-tracing simulations. In the experiments, the X-ray backlighter source is a laser-produced plasma, created by the interaction of an ultrashort pulse, Ti:Sapphire laser (120 fs, 3–5 mJ, 1016 W/cm2 on target) or a short wavelength XeCl laser (10 ns, 1–2 J, 1013 W/cm2 on target) with various solid targets (Dy, Ni + Cr, BaF2). In both experiments, the X-ray sources are well localized spatially (∼20 μm) and are spectrally tunable in a relatively wide wavelength range (λ = 8–15 Å). High quality monochromatic (δλ/λ ∼ 10−5–10−3) images with high spatial resolution (up to ∼4 μm) over a large field of view (a few square millimeters) were obtained. Utilization of spherically bent crystals to obtain high-resolution, large field, monochromatic images in a wide range of Bragg angles (35° < Θ < 90°) is demonstrated for the first time.


1970 ◽  
Vol 14 ◽  
pp. 38-56
Author(s):  
E. M. Proctor ◽  
T. C. Furnas ◽  
W. F. Loranger

AbstractThe efficiency and effectiveness of diffracted beam x-ray monochromators used in powder diffractometry have been described in so many ways that much confusion exists regarding their true performance. Although significant improvements in signal to noise ratios are readily achievable, and they offer a solution to the sample fluorescence problem, it is not without sacrifice to total intensity or achievable resolution or both. This paper discusses and describes a series of comparisons between filtered direct beam, LiF and graphite monochromators.These comparisons include the considerations necessary for the appropriate selection of diffracted beam slit system, the effect of vertical divergence as a function of two theta for singly bent crystals, the effects of a non-uniformity of contribution over the length of the crystal, and the geometry necessary for the singly bent and doubly bent crystals. The total intensity and the resolution of LiF and graphite are discussed, in particular, it is noted that the performance of monochromators with randomly oriented samples is quite different than their performance with samples showing preferred orientation or grain effects.A new diffracted beam monochromator based on the Rowland focusing geometry is described.


2020 ◽  
Vol 804 ◽  
pp. 135396 ◽  
Author(s):  
W. Scandale ◽  
G. Arduini ◽  
F. Cerutti ◽  
M. Garattini ◽  
S. Gilardoni ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document